Production of epithermal neutron beams for BNCT

被引:10
|
作者
Bisceglie, E
Colangelo, P
Colonna, N
Paticchio, V
Santorelli, P
Variale, V
机构
[1] Ist Nazl Fis Nucl, Sezione Bari, I-70126 Bari, Italy
[2] Univ Naples Federico II, Dipartimento Sci Fis, I-80125 Naples, Italy
[3] Ist Nazl Fis Nucl, I-80125 Naples, Italy
关键词
D O I
10.1016/S0168-9002(01)01406-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The use of boron neutron capture therapy (BNCT) for the treatment of deep-seated tumors requires neutron beams of suitable energy and intensity. Simulations indicate the optimal energy to reside in the epithermal region, in particular between 1 and 10 keV. Therapeutic neutron beams with high spectral purity in this energy range could be produced with accelerator-based neutron sources through a suitable neutron-producing reaction. Herein, we report on different solutions that have been investigated as possible sources of epithermal neutron beams for BNCT. The potential use of such sources for a hospital-based therapeutic facility is discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 50 条
  • [31] BNCT dose distribution in liver with epithermal D-D and D-T fusion-based neutron beams
    Koivunoro, H
    Bleuel, DL
    Nastasi, U
    Lou, TP
    Reijonen, J
    Leung, KN
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 853 - 859
  • [32] The alanine detector in BNCT dosimetry: Dose response in thermal and epithermal neutron fields
    Schmitz, T.
    Bassler, N.
    Blaickner, M.
    Ziegner, M.
    Hsiao, M. C.
    Liu, Y. H.
    Koivunoro, H.
    Auterinen, I.
    Seren, T.
    Kotiluoto, P.
    Palmans, H.
    Sharpe, P.
    Langguth, P.
    Hampel, G.
    MEDICAL PHYSICS, 2015, 42 (01) : 400 - 411
  • [33] Design of an epithermal neutron beam for BNCT in thermal column of Tehran research reactor
    Kasesaz, Yaser
    Khalafi, Hossein
    Rahmani, Faezeh
    ANNALS OF NUCLEAR ENERGY, 2014, 68 : 234 - 238
  • [34] Neutron beams implemented at nuclear research reactors for BNCT
    Bavarnegin, E.
    Kasesaz, Y.
    Wagner, F. M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [35] Dosimetry chain for the dogs irradiated in the epithermal neutron beam at the Finnish BNCT facility
    Savolainen, S
    Auterinen, I
    Aschan, C
    Hiismäki, P
    Kortesniemi, M
    Kosunen, AK
    Kotiluoto, P
    Lampinen, J
    Seppälä, T
    Serén, T
    Tanner, V
    Toivonen, M
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1245 - 1250
  • [36] Conceptual design of epithermal neutron beam for BNCT in the TRIGA reactor thermalizing column
    Maucec, M
    Glumac, B
    PROCEEDINGS OF THE WORKSHOP "MONTE CARLO METHODS AND MODELS FOR APPLICATIONS IN ENERGY AND TECHNOLOGY", 1999, 6266 : 281 - +
  • [37] MCNP study for epithermal neutron irradiation of an isolated liver at the Finnish BNCT facility
    Kotiluoto, P
    Auterinen, I
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 781 - 785
  • [38] A biological comparison of neutron beams used for BNCT research
    Mansfield, C
    Hopewell, JW
    Beynon, TD
    Huiskamp, R
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 407 - 411
  • [39] Spectrum measurements and calculations in the epithermal neutron beam at the FiR 1 BNCT facility
    Serén, T
    Auterinen, L
    Seppälä, T
    Kotiluoto, P
    15TH EUROPEAN TRIGA CONFERENCE, 1999, 197 : 167 - 179