Production of epithermal neutron beams for BNCT

被引:10
|
作者
Bisceglie, E
Colangelo, P
Colonna, N
Paticchio, V
Santorelli, P
Variale, V
机构
[1] Ist Nazl Fis Nucl, Sezione Bari, I-70126 Bari, Italy
[2] Univ Naples Federico II, Dipartimento Sci Fis, I-80125 Naples, Italy
[3] Ist Nazl Fis Nucl, I-80125 Naples, Italy
关键词
D O I
10.1016/S0168-9002(01)01406-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The use of boron neutron capture therapy (BNCT) for the treatment of deep-seated tumors requires neutron beams of suitable energy and intensity. Simulations indicate the optimal energy to reside in the epithermal region, in particular between 1 and 10 keV. Therapeutic neutron beams with high spectral purity in this energy range could be produced with accelerator-based neutron sources through a suitable neutron-producing reaction. Herein, we report on different solutions that have been investigated as possible sources of epithermal neutron beams for BNCT. The potential use of such sources for a hospital-based therapeutic facility is discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 50 条
  • [21] Biological dosimetry for epithermal neutron beams
    White, SM
    Held, KD
    Palmer, MR
    Yanch, JC
    RADIATION RESEARCH, 2001, 155 (06) : 778 - 784
  • [22] Coarse-scaling adjustment of fine-group neutron spectra for epithermal neutron beams in BNCT using multiple activation detectors
    Liu, Yuan-Hao
    Nievaart, Sander
    Tsai, Pi-En
    Liu, Hong-Ming
    Moss, Ray
    Jiang, Shiang-Huei
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (03): : 764 - 773
  • [23] Determination of an RBE for an epithermal neutron beam for BNCT from microdosimetric measurements
    Green, S
    Gainey, M
    Wojnecki, C
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1181 - 1185
  • [24] MCNP design of thermal and epithermal neutron beam for BNCT at the Isfahan MNSR
    Monshizadeh, M.
    Kasesaz, Y.
    Khalafi, H.
    Hamidi, S.
    PROGRESS IN NUCLEAR ENERGY, 2015, 83 : 427 - 432
  • [25] A DESIGN STUDY FOR AN ACCELERATOR-BASED EPITHERMAL NEUTRON BEAM FOR BNCT
    ALLEN, DA
    BEYNON, TD
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05): : 807 - 821
  • [26] Effective dose evaluation for BNCT treatment in the epithermal neutron beam at THOR
    Wang, J. N.
    Huang, C. K.
    Tsai, W. C.
    Liu, Y. H.
    Jiang, S. H.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1850 - 1853
  • [27] Experimental and theoretical evaluation of accelerator based epithermal neutron yields for BNCT
    Wielopolski, L
    Ludewig, H
    Powell, JR
    Raparia, D
    Alessi, JG
    Alburger, DE
    Zucker, MS
    Lowenstein, DI
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, PTS 1 AND 2, 1999, 475 : 1033 - 1036
  • [28] Intercomparison of three epithermal neutron-based clinical trials of BNCT
    Hideghéty, K
    Sauerwein, W
    Busse, P
    Harling, O
    Zamenhof, R
    Chanana, A
    Coderre, J
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 99 - 103
  • [29] Performance evaluation of the source description of the THOR BNCT epithermal neutron beam
    Liu, Yuan-Hao
    Tsai, Pi-En
    Yu, Hui-Ting
    Lin, Yi-Chun
    Huang, Yu-Shiang
    Huang, Chun-Kai
    Liu, Yen-Wan Hsueh
    Liu, Hong-Ming
    Jiang, Shiang-Huei
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1892 - 1896
  • [30] Biological comparison of three epithermal neutron beams
    White, SM
    Yanch, JC
    Held, KD
    Coderre, JA
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 709 - 715