Production of epithermal neutron beams for BNCT

被引:10
|
作者
Bisceglie, E
Colangelo, P
Colonna, N
Paticchio, V
Santorelli, P
Variale, V
机构
[1] Ist Nazl Fis Nucl, Sezione Bari, I-70126 Bari, Italy
[2] Univ Naples Federico II, Dipartimento Sci Fis, I-80125 Naples, Italy
[3] Ist Nazl Fis Nucl, I-80125 Naples, Italy
关键词
D O I
10.1016/S0168-9002(01)01406-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The use of boron neutron capture therapy (BNCT) for the treatment of deep-seated tumors requires neutron beams of suitable energy and intensity. Simulations indicate the optimal energy to reside in the epithermal region, in particular between 1 and 10 keV. Therapeutic neutron beams with high spectral purity in this energy range could be produced with accelerator-based neutron sources through a suitable neutron-producing reaction. Herein, we report on different solutions that have been investigated as possible sources of epithermal neutron beams for BNCT. The potential use of such sources for a hospital-based therapeutic facility is discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 50 条
  • [1] Production of epithermal neutron beams for BNCT
    Colangelo, P
    Colonna, N
    Santorelli, P
    Variale, V
    Paticchio, V
    Maggipinto, G
    EXPERIMENTAL NUCLEAR PHYSICS IN EUROPE: ENPE 99: FACING THE NEXT MILLENNIUM, 1999, 495 : 454 - 457
  • [2] A biological comparison of epithermal neutron beams for BNCT
    Mason, A.
    Beynon, D.
    Green, S.
    Monk af Rosenschold, P.
    Giusti, V.
    Hopewell, J.
    Culbertson, C.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S244 - S245
  • [3] On the optimal energy of epithermal neutron beams for BNCT
    Bisceglie, E
    Colangelo, P
    Colonna, N
    Santorelli, P
    Variale, V
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01): : 49 - 58
  • [4] Clinical Results of BNCT Using Epithermal Neutron Beams
    Nakagawa, Y.
    KURRI Progress Report, 2002,
  • [5] Proton accelerator-based epithermal neutron beams for BNCT
    Palamara, F
    Mattioda, F
    Varone, R
    Giusti, V
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 283 - 288
  • [6] Energy optimization of epithermal neutron beams for accelerator-based BNCT
    Bisceglie, E
    Colangelo, P
    Colonna, N
    Maggipinto, G
    Paticchio, V
    Raso, G
    Santorelli, P
    Variale, V
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 523 - 528
  • [7] Clinical significance of in-phantom evaluation parameters for epithermal neutron beams in BNCT
    Gupta, N
    Gahbauer, R
    Blue, TE
    Woollard, J
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A264 - A270
  • [8] Renovation of epithermal neutron beam for BNCT at THOR
    Liu, YWH
    Huang, TT
    Jiang, SH
    Liu, HM
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1039 - 1043
  • [9] A toolkit for epithermal neutron beam characterisation in BNCT
    Auterinen, I
    Serén, T
    Uusi-Simola, J
    Kosunen, A
    Savolainen, S
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 587 - 593
  • [10] Compact, inexpensive, epithermal neutron source for BNCT
    Swenson, DA
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, PTS 1 AND 2, 1999, 475 : 1037 - 1040