3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models

被引:17
|
作者
Dhou, S. [1 ,2 ]
Hurwitz, M. [1 ,2 ]
Mishra, P. [3 ]
Cai, W. [1 ,2 ]
Rottmann, J. [1 ,2 ]
Li, R. [4 ]
Williams, C. [1 ,2 ]
Wagar, M. [1 ,2 ]
Berbeco, R. [1 ,2 ]
Ionascu, D. [5 ]
Lewis, J. H. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Varian Med Syst, Palo Alto, CA USA
[4] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[5] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 09期
关键词
cone-beam CT; motion model; 3D fluoroscopic images; CONE-BEAM CT; TOTAL-VARIATION MINIMIZATION; LUNG-CANCER RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; TUMOR-LOCALIZATION; XCAT PHANTOM; RECONSTRUCTION; REGISTRATION; PROJECTIONS;
D O I
10.1088/0031-9155/60/9/3807
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we developed and performed initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and used these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparison to ground truth digital and physical phantom images. The performance of 4DCBCT-based and 4DCT-based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery.
引用
收藏
页码:3807 / 3824
页数:18
相关论文
共 50 条
  • [41] Optimization of 3D Print Material for the Recreation of Patient-Specific Temporal Bone Models
    Haffner, Max
    Quinn, Austin
    Hsieh, Tsung-yen
    Strong, E. Bradley
    Steele, Toby
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2018, 127 (05): : 338 - 343
  • [42] OPTIMISATION OF 3D PRINT MATERIAL FOR THE RECREATION OF PATIENT-SPECIFIC TEMPORAL BONE MODELS
    Quinn, A.
    Haffner, M. R.
    Hsieh, T.
    Steele, T.
    Strong, E.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2018, 66 (01) : 130 - 130
  • [43] Left atrial appendage closure guided by 3D printed patient-specific models
    Pontone, G.
    Guglielmo, M.
    Guaricci, A. I.
    Andreini, D.
    Guglielmo, M.
    Mushtaq, S.
    Conti, M.
    Marconi, S.
    Pepi, M.
    Tondo, C.
    Fassini, G.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1062 - 1062
  • [44] Microtia Ear Reconstruction with Patient-Specific 3D Models-A Segmentation Protocol
    Rodriguez-Arias, Juan Pablo
    Gutierrez Venturini, Alessandro
    Pampin Martinez, Marta Maria
    Gomez Garcia, Elena
    Munoz Caro, Jesus Manuel
    San Basilio, Maria
    Martin Perez, Mercedes
    Cebrian Carretero, Jose Luis
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (13)
  • [45] A METHOD TO GENERATE 3D PATIENT-SPECIFIC TOTAL KNEE ARTHROPLASTY TIBIA MODELS
    Gothard, Andrew T.
    Anton, Steven R.
    PROCEEDINGS OF ASME 2022 CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, SMASIS2022, 2022,
  • [46] An overview of 3D printing and the orthopaedic application of patient-specific models in malunion surgery
    Thomas, Claire N.
    Mavrommatis, Sophia
    Schroder, Lisa K.
    Cole, Peter A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (03): : 977 - 983
  • [47] Image motion estimation for 3D model based video conferencing
    Cheung, MK
    Tsui, HT
    15TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 3, PROCEEDINGS: IMAGE, SPEECH AND SIGNAL PROCESSING, 2000, : 827 - 830
  • [48] PATIENT-SPECIFIC MITRAL VALVE CLOSURE PREDICTION USING 3D ECHOCARDIOGRAPHY
    Burlina, Philippe
    Sprouse, Chad
    Mukherjee, Ryan
    DeMenthon, Daniel
    Abraham, Theodore
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05): : 769 - 783
  • [49] Recapitulation of patient-specific 3D chromatin conformation using machine learning
    Xu, Duo
    Forbes, Andre Neil
    Cohen, Sandra
    Palladino, Ann
    Karadimitriou, Tatiana
    Khurana, Ekta
    CELL REPORTS METHODS, 2023, 3 (09):
  • [50] Development of patient-specific molecular imaging phantoms using a 3D printer
    Gear, J. I.
    Long, C.
    Rushforth, D.
    Chittenden, S. J.
    Cummings, C.
    Flux, G. D.
    MEDICAL PHYSICS, 2014, 41 (08) : 525 - 527