3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models

被引:17
|
作者
Dhou, S. [1 ,2 ]
Hurwitz, M. [1 ,2 ]
Mishra, P. [3 ]
Cai, W. [1 ,2 ]
Rottmann, J. [1 ,2 ]
Li, R. [4 ]
Williams, C. [1 ,2 ]
Wagar, M. [1 ,2 ]
Berbeco, R. [1 ,2 ]
Ionascu, D. [5 ]
Lewis, J. H. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Varian Med Syst, Palo Alto, CA USA
[4] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[5] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 09期
关键词
cone-beam CT; motion model; 3D fluoroscopic images; CONE-BEAM CT; TOTAL-VARIATION MINIMIZATION; LUNG-CANCER RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; TUMOR-LOCALIZATION; XCAT PHANTOM; RECONSTRUCTION; REGISTRATION; PROJECTIONS;
D O I
10.1088/0031-9155/60/9/3807
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we developed and performed initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and used these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparison to ground truth digital and physical phantom images. The performance of 4DCBCT-based and 4DCT-based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery.
引用
收藏
页码:3807 / 3824
页数:18
相关论文
共 50 条
  • [31] Initial Clinical Experience Using 3d Printing And Patient-Specific Airway Stents: Compassionate Use Of 3d Printed Patient-Specific Airway Stents
    Young, B. P.
    Machuzak, M. S.
    Gildea, T. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [32] A patient-specific deep learning framework for 3D motion estimation and volumetric imaging during lung cancer radiotherapy
    Hindley, Nicholas
    Shieh, Chun-Chien
    Keall, Paul
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14):
  • [34] Patient-specific finite element modeling of respiratory lung motion using 4D CT image data
    Werner, Rene
    Ehrhardt, Jan
    Schmidt, Rainer
    Handels, Heinz
    MEDICAL PHYSICS, 2009, 36 (05) : 1500 - 1511
  • [35] Patient-Specific 3D Printed Models of Renal Tumours Using Home-Made 3D Printer in Comparison with Commercial 3D Printer
    Liu, Dongting
    Sun, Zhonghua
    Chaichana, Thanapong
    Ducke, Werner
    Fan, Zhanming
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 303 - 308
  • [36] Development of 3D printed patient-specific skull implants based on 3d surface scans
    Fabian Kropla
    Dirk Winkler
    Dirk Lindner
    Patrick Knorr
    Sebastian Scholz
    Ronny Grunert
    3D Printing in Medicine, 9
  • [37] Development of 3D printed patient-specific skull implants based on 3d surface scans
    Kropla, Fabian
    Winkler, Dirk
    Lindner, Dirk
    Knorr, Patrick
    Scholz, Sebastian
    Grunert, Ronny
    3D PRINTING IN MEDICINE, 2023, 9 (01)
  • [38] A 3D ultrasound system for image guided modeling of patient-specific artery geometries
    Hammer, Steven J.
    Jeays, Adam
    Lee, William T.
    Barber, David
    Hose, Rod
    Easson, William J.
    Hoskins, Peter R.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2469 - +
  • [39] Bioprinting of 3D patient-specific auricular scaffolds
    Martinez, H.
    Sundberg, J.
    Prakash, S.
    Seniger, M.
    Gatenholm, P.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 153 - 153
  • [40] Applications of patient-specific 3D printing in medicine
    Heller, M.
    Bauer, H-K.
    Goetze, E.
    Gielisch, M.
    Roth, K. E.
    Maier, G. S.
    Drees, P.
    Dorweiler, B.
    Ghazy, A.
    Neufurth, M.
    Mueller, W. E. G.
    Schoerder, H. C.
    Wang, X. H.
    Vahl, C-F
    Al-Nawas, B.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2016, 19 (04) : 323 - 339