3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models

被引:17
|
作者
Dhou, S. [1 ,2 ]
Hurwitz, M. [1 ,2 ]
Mishra, P. [3 ]
Cai, W. [1 ,2 ]
Rottmann, J. [1 ,2 ]
Li, R. [4 ]
Williams, C. [1 ,2 ]
Wagar, M. [1 ,2 ]
Berbeco, R. [1 ,2 ]
Ionascu, D. [5 ]
Lewis, J. H. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Varian Med Syst, Palo Alto, CA USA
[4] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[5] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 09期
关键词
cone-beam CT; motion model; 3D fluoroscopic images; CONE-BEAM CT; TOTAL-VARIATION MINIMIZATION; LUNG-CANCER RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; TUMOR-LOCALIZATION; XCAT PHANTOM; RECONSTRUCTION; REGISTRATION; PROJECTIONS;
D O I
10.1088/0031-9155/60/9/3807
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we developed and performed initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and used these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparison to ground truth digital and physical phantom images. The performance of 4DCBCT-based and 4DCT-based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery.
引用
收藏
页码:3807 / 3824
页数:18
相关论文
共 50 条
  • [21] Patient-Specific 3D Virtual Surgical Planning Using Simulated Fluoroscopic Images to Improve Sacroiliac Joint Fusion
    Kampkuiper, Nick
    Nellensteijn, Jorm
    Hekman, Edsko
    Tuijthof, Gabrielle
    Lankheet, Steven
    Koenrades, Maaike
    Schroder, Femke
    BIOMECHANICS, 2023, 3 (04): : 511 - 522
  • [22] Patient-specific respiratory models using dynamic 3D MRI: Preliminary volunteer results
    Miquel, M. E.
    Blackall, J. M.
    Uribe, S.
    Hawkes, D. J.
    Schaeffter, T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (02): : 214 - 220
  • [23] Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
    Peterman, Emma L.
    Kolewe, Emily L.
    Fromen, Catherine A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (165): : 1 - 16
  • [24] ESTIMATION OF PATIENT-SPECIFIC 3D IN VIVO ABDOMINAL AORTIC ANEURYSM STRAIN
    Raut, Samarth S.
    Jana, Anirban
    Muluk, Satish C.
    Doyle, Mark
    Biederman, Robert W.
    Finol, Ender A.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [25] A hybrid patient-specific biomechanical model based image registration method for the motion estimation of lungs
    Han, Lianghao
    Dong, Hua
    McClelland, Jamie R.
    Han, Liangxiu
    Hawkes, David J.
    Barratt, Dean C.
    MEDICAL IMAGE ANALYSIS, 2017, 39 : 87 - 100
  • [26] The development of patient-specific 3D anatomical models in minimally invasive parathyroidectomy
    Haq, Zahra J.
    Ahmed, Ahmed
    Abdelsalam, Alaa
    Chegini, Soudeh
    Kurzawinski, Tom R.
    Morley, Simon
    Mcgurk, Mark
    Abdel-Aziz, Tarek
    FRONTIERS IN ENDOCRINOLOGY, 2024, 15
  • [27] Segmentation and generation of patient-specific 3D models of anatomy for surgical simulation
    Smith, M
    Faraci, A
    Bello, F
    MEDICINE MEETS VIRTUAL REALITY 12: BUILDING A BETTER YOU: THE NEXT TOOLS FOR MEDICAL EDUCATION, DIAGNOSIS , AND CARE, 2004, 98 : 360 - 362
  • [28] Patient-Specific 3D Printed Models of Aortic Aneurysm and Aortic Dissection
    Sun, Zhonghua
    Squelch, Andrew
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (04) : 886 - 889
  • [29] Patient-specific Respiratory Motion Estimation Using Sparse Motion Field Presentation
    Chen, Dong
    Xie, Hongzhi
    Zhang, Shuyang
    Chen, Weisheng
    Gu, Lixu
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 584 - 587
  • [30] Estimation of 3D Fluoroscopic Treatment Images Using a Single Cine EPID Image
    Mishra, P.
    Li, R.
    Williams, C.
    Berbeco, R.
    Lewis, J.
    MEDICAL PHYSICS, 2013, 40 (06)