Monte Carlo dose verification for intensity-modulated arc therapy

被引:32
|
作者
Li, XA [1 ]
Ma, LJ [1 ]
Naqvi, S [1 ]
Shih, RP [1 ]
Yu, C [1 ]
机构
[1] Univ Maryland, Dept Radiat Oncol, Baltimore, MD 21201 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 09期
关键词
D O I
10.1088/0031-9155/46/9/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intensity-modulated are therapy (IMAT), a technique which combines beam rotation and dynamic multileaf collimation, has been implemented in our clinic. Dosimetric errors can be created by the inability of the planning system to accurately account for the effects of tissue inhomogeneities and physical characteristics of the multileaf collimator (MLC). The objective of this study is to explore the use of Monte Carlo (MC) simulation for IMAT dose verification. The BEAM/DOSXYZ Monte Carlo system was implemented to perform dose verification for the IMAT treatment. The implementation includes the simulation of the linac head/MLC (Elekta SL20), the conversion of patient CT images and beam arrangement for 3D dose calculation, the calculation of gantry rotation and leaf motion by a series of static beams and the development of software to automate the entire MC process. The MC calculations were verified by measurements for conventional beam settings. The agreement was within 2%. The IMAT dose distributions generated by a commercial forward planning system (RenderPlan, Elekta) were compared with those calculated by the MC package. For the cases studied, discrepancies of over 10% were found between the MC and the RenderPlan dose calculations. These discrepancies were due in part to the inaccurate dose calculation of the RenderPlan system. The computation time for the IMAT MC calculation was in the range of 20-80 min on 15 Pentium-III computers. The MC method was also useful in verifying the beam apertures used in the IMAT treatments.
引用
收藏
页码:2269 / 2282
页数:14
相关论文
共 50 条
  • [41] The Monte Carlo simulation on the dose disturbance effect of the dentures in intensity modulated radiation therapy
    Sheu, R
    Yeh, C
    Chen, C
    Lee, C
    Chao, T
    Chang, B
    MEDICAL PHYSICS, 2004, 31 (06) : 1921 - 1921
  • [42] Monte Carlo in the optimization of intensity modulated proton therapy
    Soukup, M.
    Alber, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2471 - 2471
  • [43] Evaluation of Integral Dose in Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy for Head and Neck Cancer Patient
    Al-Basheer, A.
    Hunag, J.
    Kaminski, J.
    Dasher, B.
    Howington, J.
    Stewart, J.
    Martin, D.
    Kong, F.
    Jin, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 260 - 261
  • [44] Comparison of Intensity-Modulated Arc Therapy and Intensity-Modulated Radiotherapy Plans for Nasopharyngeal Carcinoma Simultaneously Integrated Boost Radiation Therapy
    Liu, T.
    Bai, T.
    Chen, J.
    Zhang, G.
    Ma, C.
    Yin, Y.
    Lin, X.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S563 - S563
  • [45] Comparison of Intensity-Modulated Arc Therapy and Intensity-Modulated Radiotherapy Plans for Nasopharyngeal Carcinoma Simultaneously Integrated Boost Radiation Therapy
    Liu, T.
    Yin, Y.
    Bai, T.
    Chen, J.
    Lu, J.
    Sun, T.
    Gao, M.
    Ma, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [46] Dose verification and plan conformity with three different dosimeters for intensity-modulated radiation therapy plans
    Yassin, A.
    Elshahat, K. M.
    Attlah, E. M.
    Khaled, H.
    Kany, A.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (03): : 703 - 710
  • [47] Monte Carlo Simulation Dose Calculation for Intensity Modulated Radiosurgery
    Chan, K.
    Schneider, M.
    Smee, R.
    Heng, S.
    Baldock, C.
    RADIOSURGERY, VOL 7, 2010, 7 : 84 - 94
  • [48] MONTE CARLO VERIFICATION OF INTENSITY MODULATED RADIOTHERAPY TREATMENTS USING EPIDS
    Perera, L.
    Boyd, J.
    Doody, J.
    Moody, M.
    Sandford, P.
    Fielding, A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S439 - S439
  • [49] A method of simulating dynamic multileaf collimators using Monte Carlo techniques for intensity-modulated radiation therapy
    Liu, HH
    Verhaegen, F
    Dong, L
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09): : 2283 - 2298
  • [50] Intensity-modulated arc therapy: principles, technologies and clinical implementation
    Yu, Cedric X.
    Tang, Grace
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (05): : R31 - R54