Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: A systematic review and meta-analysis

被引:91
|
作者
Cheng, Hao-Min [1 ,2 ,3 ]
Lang, Dora [1 ,4 ]
Tufanaru, Catalin [1 ]
Pearson, Alan [1 ]
机构
[1] Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
[2] Taipei Vet Gen Hosp, Dept Med Res & Educ, Taipei, Taiwan
[3] Natl Yang Ming Univ, Dept Med, Taipei 112, Taiwan
[4] Natl Univ Singapore Hosp, Ctr Evidence Based Nursing, Singapore 117548, Singapore
关键词
Central blood pressure; Applanation tonometry; Transfer function; SphygmoCor; Late systolic peak; Sphygmomanometer; CENTRAL AORTIC PRESSURE; ARTERIAL TRANSFER-FUNCTIONS; LOW-DOSE COMBINATION; WAVE-FORM; PULSE PRESSURE; CARDIOVASCULAR EVENTS; UPPER-LIMB; HYPERTENSIVE SUBJECTS; VALIDATION; DERIVATION;
D O I
10.1016/j.ijcard.2012.04.155
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: Non-invasive methods based on applanation tonometry have been proposed to estimate central blood pressure. However, the accuracy of these methods hasn't been systematically examined. Methods: We performed a systematic review and meta-analysis of studies comparing estimated and invasively measured central BP. Results: Sufficient data were available in 22 studies for meta-analysis (857 subjects and 1167 measurements). Acquired arterial pressure waveforms in these studies were directly measured, calibrated to match invasive aortic mean BP and diastolic BP or calibrated to match brachial BP measured with a sphygmomanometer, cuff BP. Of the former 2 conditions, the errors of estimated central BP were small with a mean and standard deviation of difference -1.1 +/- 4.1 mm Hg (95% limits of agreement -9.1-6.9 mm Hg) for central systolic BP; -0.5 +/- 2.1 mm Hg (-4.6-3.6 mm Hg) for central diastolic BP; and -0.8 +/- 5.1 mm Hg (-10.8-9.2 mm Hg) for central pulse pressure. However, the errors inflated to -8.2 +/- 10.3 mm Hg (-28.4-12.0 mm Hg) for central systolic BP, 7.6 +/- 8.7 mm Hg (-9.5-24.6 mm Hg) for central diastolic BP, and -12.2 +/- 10.4 mm Hg (-32.5-8.1 mm Hg) for central pulse pressure, when calibrated to cuff BP. The findings were still evident in subgroup analysis conducted with different central BP estimating methods and validated cuff BP monitors. Conclusion: Present tonometry-based central BP estimating methods are acceptable in theory, with small errors. However, based on current available evidence, there is substantial room for improvement in measurement accuracy of central BP when cuff BP is used to calibrate the peripheral waveforms. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1867 / 1876
页数:10
相关论文
共 50 条
  • [21] Effect of applanation tonometry on accuracy of central corneal thickness measurements obtained with contact versus non contact modality
    Banoub, Raphael
    Cheng, Anny
    Eaddy, Isabel
    Sibia, Adiraj
    Chalam, K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [22] Aortic systolic and pulse pressure invasively and non-invasively obtained: Comparative analysis of recording techniques, arterial sites of measurement, waveform analysis algorithms and calibration methods
    Bia, Daniel
    Zocalo, Yanina
    Sanchez, Ramiro
    Lev, Gustavo
    Mendiz, Oscar
    Pessana, Franco
    Ramirez, Agustin
    Cabrera-Fischer, Edmundo, I
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [23] BRACHIAL-TO-RADIAL-SYSTOLIC-BLOOD-PRESSURE-AMPLIFICATION AND THE IMPACT ON NON-INVASIVELY DERIVED CENTRAL SYSTOLIC BLOOD PRESSURE
    Picone, D. S.
    Climie, R. E. D.
    Ahuja, K. D. K.
    Keske, M. A.
    Sharman, J. E.
    HYPERTENSION, 2014, 63 (06) : E148 - E148
  • [24] Accuracy of intracranial pressure monitoring: systematic review and meta-analysis
    Lucia Zacchetti
    Sandra Magnoni
    Federica Di Corte
    Elisa R. Zanier
    Nino Stocchetti
    Critical Care, 19
  • [25] Accuracy of intracranial pressure monitoring: systematic review and meta-analysis
    Zacchetti, Lucia
    Magnoni, Sandra
    Di Corte, Federica
    Zanier, Elisa R.
    Stocchetti, Nino
    CRITICAL CARE, 2015, 19
  • [26] Automated blood pressure measurement in atrial fibrillation: a systematic review and meta-analysis Reply
    Stergiou, George S.
    Kollias, Anastasios
    Destounis, Antonios
    Tzamouranis, Dimitrios
    JOURNAL OF HYPERTENSION, 2013, 31 (01) : 215 - 216
  • [27] Oscillometric and auscultatory blood pressure measurement methods in children: a systematic review and meta-analysis
    Duncombe, Stephanie L.
    Voss, Christine
    Harris, Kevin C.
    JOURNAL OF HYPERTENSION, 2017, 35 (02) : 213 - 224
  • [28] Pulse Wave Calibration and Implications for Blood Pressure Measurement: Systematic Review and Meta-Analysis
    Jedrzejewski, Dawid
    McFarlane, Ewan
    Lacy, Peter S.
    Williams, Bryan
    HYPERTENSION, 2021, 78 (02) : 360 - 371
  • [29] Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysis
    Christopher E. Clark
    Sinead T. J. McDonagh
    Richard J. McManus
    Journal of Human Hypertension, 2019, 33 : 352 - 364
  • [30] Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysis
    Clark, Christopher E.
    McDonagh, Sinead T. J.
    McManus, Richard J.
    JOURNAL OF HUMAN HYPERTENSION, 2019, 33 (05) : 352 - 364