Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: A systematic review and meta-analysis

被引:91
|
作者
Cheng, Hao-Min [1 ,2 ,3 ]
Lang, Dora [1 ,4 ]
Tufanaru, Catalin [1 ]
Pearson, Alan [1 ]
机构
[1] Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
[2] Taipei Vet Gen Hosp, Dept Med Res & Educ, Taipei, Taiwan
[3] Natl Yang Ming Univ, Dept Med, Taipei 112, Taiwan
[4] Natl Univ Singapore Hosp, Ctr Evidence Based Nursing, Singapore 117548, Singapore
关键词
Central blood pressure; Applanation tonometry; Transfer function; SphygmoCor; Late systolic peak; Sphygmomanometer; CENTRAL AORTIC PRESSURE; ARTERIAL TRANSFER-FUNCTIONS; LOW-DOSE COMBINATION; WAVE-FORM; PULSE PRESSURE; CARDIOVASCULAR EVENTS; UPPER-LIMB; HYPERTENSIVE SUBJECTS; VALIDATION; DERIVATION;
D O I
10.1016/j.ijcard.2012.04.155
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: Non-invasive methods based on applanation tonometry have been proposed to estimate central blood pressure. However, the accuracy of these methods hasn't been systematically examined. Methods: We performed a systematic review and meta-analysis of studies comparing estimated and invasively measured central BP. Results: Sufficient data were available in 22 studies for meta-analysis (857 subjects and 1167 measurements). Acquired arterial pressure waveforms in these studies were directly measured, calibrated to match invasive aortic mean BP and diastolic BP or calibrated to match brachial BP measured with a sphygmomanometer, cuff BP. Of the former 2 conditions, the errors of estimated central BP were small with a mean and standard deviation of difference -1.1 +/- 4.1 mm Hg (95% limits of agreement -9.1-6.9 mm Hg) for central systolic BP; -0.5 +/- 2.1 mm Hg (-4.6-3.6 mm Hg) for central diastolic BP; and -0.8 +/- 5.1 mm Hg (-10.8-9.2 mm Hg) for central pulse pressure. However, the errors inflated to -8.2 +/- 10.3 mm Hg (-28.4-12.0 mm Hg) for central systolic BP, 7.6 +/- 8.7 mm Hg (-9.5-24.6 mm Hg) for central diastolic BP, and -12.2 +/- 10.4 mm Hg (-32.5-8.1 mm Hg) for central pulse pressure, when calibrated to cuff BP. The findings were still evident in subgroup analysis conducted with different central BP estimating methods and validated cuff BP monitors. Conclusion: Present tonometry-based central BP estimating methods are acceptable in theory, with small errors. However, based on current available evidence, there is substantial room for improvement in measurement accuracy of central BP when cuff BP is used to calibrate the peripheral waveforms. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1867 / 1876
页数:10
相关论文
共 50 条
  • [41] Effect of garlic on blood pressure: A systematic review and meta-analysis
    Ried, Karin
    Frank, Oliver R.
    Stocks, Nigel P.
    Fakler, Peter
    Sullivan, Thomas
    BMC CARDIOVASCULAR DISORDERS, 2008, 8 (1)
  • [42] Fluoride Exposure and Blood Pressure: a Systematic Review and Meta-Analysis
    Meng Li
    Yannan Zhao
    Xiaolin Tian
    Penghui Liu
    Jiaxin Xie
    Nisha Dong
    Jing Feng
    Yi Gao
    Ye Fan
    Yulan Qiu
    Fengjie Tian
    Xiaoyan Yan
    Biological Trace Element Research, 2021, 199 : 925 - 934
  • [43] Fluoride Exposure and Blood Pressure: a Systematic Review and Meta-Analysis
    Li, Meng
    Zhao, Yannan
    Tian, Xiaolin
    Liu, Penghui
    Xie, Jiaxin
    Dong, Nisha
    Feng, Jing
    Gao, Yi
    Fan, Ye
    Qiu, Yulan
    Tian, Fengjie
    Yan, Xiaoyan
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2021, 199 (03) : 925 - 934
  • [44] CENTRAL-TO-BRACHIAL BLOOD PRESSURE AMPLIFICATION IN PATIENTS TYPE 2 DIABETES MELLITUS: A SYSTEMATIC REVIEW AND META-ANALYSIS OF NON-INVASIVE MEASUREMENT
    Climie, R. E. D.
    Otahal, P.
    Schultz, M. G.
    Fell, J. W.
    Srikanth, V
    Sharman, J. E.
    HYPERTENSION, 2016, 67 (05) : E17 - E17
  • [45] Home measurement of blood pressure and cardiovascular disease: systematic review and meta-analysis of prospective studies
    Ward, Alison M.
    Takahashi, Osamu
    Stevens, Richard
    Heneghan, Carl
    JOURNAL OF HYPERTENSION, 2012, 30 (03) : 449 - 456
  • [46] Seasonal blood pressure variation assessed by different measurement methods: systematic review and meta-analysis
    Kollias, Anastasios
    Kyriakoulis, Konstantinos G.
    Stambolliu, Emelina
    Ntineri, Angeliki
    Anagnostopoulos, Ioannis
    Stergiou, George S.
    JOURNAL OF HYPERTENSION, 2020, 38 (05) : 791 - 798
  • [47] ATRIAL FIBRILLATION DETECTION DURING AUTOMATED BLOOD PRESSURE MEASUREMENT: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Kyriakoulis, K.
    Kollias, A.
    Stambolliu, E.
    Stergiou, G. S.
    JOURNAL OF HYPERTENSION, 2018, 36 : E60 - E60
  • [48] SEASONAL BLOOD PRESSURE VARIATION ASSESSED BY DIFFERENT MEASUREMENT METHODS: SYSTEMATIC REVIEW AND META-ANALYSIS
    Kollias, A.
    Kyriakoulis, K.
    Stambolliu, E.
    Stergiou, G. S.
    JOURNAL OF HYPERTENSION, 2019, 37 : E79 - E79
  • [49] Blood and Urine Cadmium, Blood Pressure, and Hypertension: A Systematic Review and Meta-analysis
    Gallagher, Carolyn M.
    Meliker, Jaymie R.
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2010, 118 (12) : 1676 - 1684
  • [50] Central venous pressure and liver resection: a systematic review and meta-analysis
    Hughes, Michael J.
    Ventham, Nicholas T.
    Harrison, Ewen M.
    Wigmore, Stephen J.
    HPB, 2015, 17 (10) : 863 - 871