Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: A systematic review and meta-analysis
被引:91
|
作者:
Cheng, Hao-Min
论文数: 0引用数: 0
h-index: 0
机构:
Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
Taipei Vet Gen Hosp, Dept Med Res & Educ, Taipei, Taiwan
Natl Yang Ming Univ, Dept Med, Taipei 112, TaiwanUniv Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
Cheng, Hao-Min
[1
,2
,3
]
Lang, Dora
论文数: 0引用数: 0
h-index: 0
机构:
Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
Natl Univ Singapore Hosp, Ctr Evidence Based Nursing, Singapore 117548, SingaporeUniv Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
Lang, Dora
[1
,4
]
Tufanaru, Catalin
论文数: 0引用数: 0
h-index: 0
机构:
Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, AustraliaUniv Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
Tufanaru, Catalin
[1
]
Pearson, Alan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, AustraliaUniv Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
Pearson, Alan
[1
]
机构:
[1] Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
[2] Taipei Vet Gen Hosp, Dept Med Res & Educ, Taipei, Taiwan
[3] Natl Yang Ming Univ, Dept Med, Taipei 112, Taiwan
Central blood pressure;
Applanation tonometry;
Transfer function;
SphygmoCor;
Late systolic peak;
Sphygmomanometer;
CENTRAL AORTIC PRESSURE;
ARTERIAL TRANSFER-FUNCTIONS;
LOW-DOSE COMBINATION;
WAVE-FORM;
PULSE PRESSURE;
CARDIOVASCULAR EVENTS;
UPPER-LIMB;
HYPERTENSIVE SUBJECTS;
VALIDATION;
DERIVATION;
D O I:
10.1016/j.ijcard.2012.04.155
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background and objectives: Non-invasive methods based on applanation tonometry have been proposed to estimate central blood pressure. However, the accuracy of these methods hasn't been systematically examined. Methods: We performed a systematic review and meta-analysis of studies comparing estimated and invasively measured central BP. Results: Sufficient data were available in 22 studies for meta-analysis (857 subjects and 1167 measurements). Acquired arterial pressure waveforms in these studies were directly measured, calibrated to match invasive aortic mean BP and diastolic BP or calibrated to match brachial BP measured with a sphygmomanometer, cuff BP. Of the former 2 conditions, the errors of estimated central BP were small with a mean and standard deviation of difference -1.1 +/- 4.1 mm Hg (95% limits of agreement -9.1-6.9 mm Hg) for central systolic BP; -0.5 +/- 2.1 mm Hg (-4.6-3.6 mm Hg) for central diastolic BP; and -0.8 +/- 5.1 mm Hg (-10.8-9.2 mm Hg) for central pulse pressure. However, the errors inflated to -8.2 +/- 10.3 mm Hg (-28.4-12.0 mm Hg) for central systolic BP, 7.6 +/- 8.7 mm Hg (-9.5-24.6 mm Hg) for central diastolic BP, and -12.2 +/- 10.4 mm Hg (-32.5-8.1 mm Hg) for central pulse pressure, when calibrated to cuff BP. The findings were still evident in subgroup analysis conducted with different central BP estimating methods and validated cuff BP monitors. Conclusion: Present tonometry-based central BP estimating methods are acceptable in theory, with small errors. However, based on current available evidence, there is substantial room for improvement in measurement accuracy of central BP when cuff BP is used to calibrate the peripheral waveforms. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
机构:
SUNY Stony Brook, Med Ctr, Sch Med, Doctoral Program Populat Hlth & Clin Outcomes Res, Stony Brook, NY 11794 USA
SUNY Stony Brook, Med Ctr, Dept Prevent Med, Stony Brook, NY 11794 USASUNY Stony Brook, Med Ctr, Sch Med, Doctoral Program Populat Hlth & Clin Outcomes Res, Stony Brook, NY 11794 USA
Gallagher, Carolyn M.
Meliker, Jaymie R.
论文数: 0引用数: 0
h-index: 0
机构:
SUNY Stony Brook, Med Ctr, Dept Prevent Med, Stony Brook, NY 11794 USA
SUNY Stony Brook, Grad Program Publ Hlth, Stony Brook, NY 11794 USASUNY Stony Brook, Med Ctr, Sch Med, Doctoral Program Populat Hlth & Clin Outcomes Res, Stony Brook, NY 11794 USA