Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis

被引:160
|
作者
Rizzo, S
Kalra, M
Schmidt, B
Dalal, T
Suess, C
Flohr, T
Blake, M
Saini, S
机构
[1] Emory Univ Hosp, Dept Radiol, Atlanta, GA 30322 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Siemens Med Solut, Forchheim, Germany
关键词
abdomen; CT technique; pelvis; radiation dose; tube current modulation;
D O I
10.2214/AJR.04.1513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to compare image quality and radiation dose associated with abdominopelvic CT using combined modulation, angular modulation, and constant tube current. CONCLUSION. Compared with using a constant tube current to scan the abdomen and pelvis, the use of a combined modulation technique results in a substantial reduction (42-44%) in radiation dose with acceptable image noise and diagnostic acceptability.
引用
收藏
页码:673 / 679
页数:7
相关论文
共 50 条
  • [41] A phantom study to optimise the automatic tube current modulation for chest CT in COVID-19
    Gombolevskiy, Victor
    Morozov, Sergey
    Chernina, Valeria
    Blokhin, Ivan
    Vassileva, Jenia
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [42] Automatic tube current modulation for volume scan in a 320-detector row CT scanner
    Liao, Y. L.
    Lai, N. K.
    Tyan, Y. S.
    Chuang, K. S.
    Tsai, H. Y.
    RADIATION MEASUREMENTS, 2013, 56 : 328 - 332
  • [43] Evaluating the impact of scan settings on automatic tube current modulation in CT using a novel phantom
    Merzan, Deborah
    Nowik, Patrik
    Poludniowski, Gavin
    Bujila, Robert
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1069):
  • [44] Evaluating Effective Doses and Image Quality for Multislice CT Using Automatic Tube Current Modulation
    Tsai, S. F.
    Tsai, H. Y.
    Tyan, Y. S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [45] Misoperation of CT Automatic Tube Current Modulation Systems with Inappropriate Patient Centering: Phantom Studies
    Matsubara, Kosuke
    Koshida, Kichiro
    Ichikawa, Katsuhiro
    Suzuki, Masayuki
    Takata, Tadanori
    Yamamoto, Tomoyuki
    Matsui, Osamu
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : 862 - 865
  • [46] Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation
    Saltybaeva, Natalia
    Krauss, Andreas
    Alkadhi, Hatem
    RADIOLOGY, 2017, 282 (03) : 842 - 849
  • [47] A phantom study to optimise the automatic tube current modulation for chest CT in COVID-19
    Victor Gombolevskiy
    Sergey Morozov
    Valeria Chernina
    Ivan Blokhin
    Jenia Vassileva
    European Radiology Experimental, 5
  • [48] Evaluation of automatic tube current modulation of CT scanners using a dedicated and the CTDI dosimetry phantoms
    Tsalafoutas, Ioannis A.
    AlKhazzam, Shady
    AlNaemi, Huda
    Kharita, Mohammed Hassan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [49] Estimating fetal dose from tube current-modulated (TCM) and fixed tube current (FTC) abdominal/pelvis CT examinations
    Hardy, Anthony J.
    Angel, Erin
    Bostani, Maryam
    Cagnon, Chris
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2019, 46 (06) : 2729 - 2743
  • [50] A Study of Fixed Current and Automatic Tube Current Modulation at a Fixed Low Tube Voltage in Low-dose Computed Tomography (CT) Imaging of Infant Lungs
    Chen, Wushuang
    Tang, Shilong
    Xu, Zhen
    Chen, Xin
    Zheng, Yinglan
    He, Ling
    IRANIAN JOURNAL OF RADIOLOGY, 2023, 20 (02)