Evaluating the impact of scan settings on automatic tube current modulation in CT using a novel phantom
被引:27
|
作者:
Merzan, Deborah
论文数: 0引用数: 0
h-index: 0
机构:
Karolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, SwedenKarolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
Merzan, Deborah
[1
]
Nowik, Patrik
论文数: 0引用数: 0
h-index: 0
机构:
Karolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, SwedenKarolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
Nowik, Patrik
[1
]
Poludniowski, Gavin
论文数: 0引用数: 0
h-index: 0
机构:
Karolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, SwedenKarolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
Poludniowski, Gavin
[1
]
Bujila, Robert
论文数: 0引用数: 0
h-index: 0
机构:
Karolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
Royal Inst Technol, Dept Phys, SE-10691 Stockholm, SwedenKarolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
Bujila, Robert
[1
,2
]
机构:
[1] Karolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
[2] Royal Inst Technol, Dept Phys, SE-10691 Stockholm, Sweden
Objective: The aim of this study was to make a comprehensive evaluation of how variable scan settings can affect the performance of automatic tube current modulation (ATCM) in recent CT scanners from the four major manufacturers. Methods: A phantom was designed and manufactured for the purpose of evaluating ATCM. The phantom was scanned with four categories of systematically varied settings (scan projection radiograph, technique and reconstruction parameters and phantom miscentring). The performance of ATCM, in terms of applied tube current and noise uniformity, for the scans with varied settings was compared with a reference scan using subjective and quantitative approaches. Results: The ATCM implemented by each manufacturer is based on different principles and any affect to the performance of the ATCM, when varying scan settings, will manifest differently among the vendors. The results are summarized in four tables corresponding to the categories of varied settings. Conclusion: The developed phantom proved useful for evaluating the ATCM. It is important to understand how different implementations (vendor specific) of ATCM perform in order to make informed decisions about the selection of scan settings when designing protocols. The resulting tables can serve as a reference for understanding the different implementations of ATCM and highlight settings that should be taken into consideration when adjusting an imaging protocol. Advances in knowledge: The results from this work can serve as a reference for how changes in geometry or scan settings can affect the performance of ATCM, in terms of tube current and noise.
机构:
Univ Indonesia, Fac Math & Nat Sci, Dept Phys, Depok 16424, Indonesia
Cipto Mangunkusumo Natl Cent Gen Hosp, Installat Radiol & Nucl Med, Jakarta 10430, IndonesiaUniv Indonesia, Fac Math & Nat Sci, Dept Phys, Depok 16424, Indonesia
Taopik, A.
Lubis, L. E.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Indonesia, Fac Math & Nat Sci, Dept Phys, Depok 16424, Indonesia
Univ Indonesia Hosp, Radiol Unit, Depok 16424, IndonesiaUniv Indonesia, Fac Math & Nat Sci, Dept Phys, Depok 16424, Indonesia
Lubis, L. E.
Sihono, D. S. K.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Indonesia, Fac Math & Nat Sci, Dept Phys, Depok 16424, IndonesiaUniv Indonesia, Fac Math & Nat Sci, Dept Phys, Depok 16424, Indonesia
Sihono, D. S. K.
Soejoko, D. S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Indonesia, Fac Math & Nat Sci, Dept Phys, Depok 16424, IndonesiaUniv Indonesia, Fac Math & Nat Sci, Dept Phys, Depok 16424, Indonesia
机构:Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department,Radiation Protection of Patients Unit
Victor Gombolevskiy
Sergey Morozov
论文数: 0引用数: 0
h-index: 0
机构:Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department,Radiation Protection of Patients Unit
Sergey Morozov
Valeria Chernina
论文数: 0引用数: 0
h-index: 0
机构:Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department,Radiation Protection of Patients Unit
Valeria Chernina
Ivan Blokhin
论文数: 0引用数: 0
h-index: 0
机构:Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department,Radiation Protection of Patients Unit
Ivan Blokhin
Jenia Vassileva
论文数: 0引用数: 0
h-index: 0
机构:Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department,Radiation Protection of Patients Unit