Continuous Noninvasive Hemoglobin Monitor from Pulse Ox: Ready for Prime Time?

被引:23
|
作者
Joseph, Bellal [1 ]
Hadjizacharia, Pantelis [1 ]
Aziz, Hassan [1 ]
Snyder, Kara [1 ]
Wynne, Julie [1 ]
Kulvatunyou, Narong [1 ]
Tang, Andrew [1 ]
O'Keeffe, Terence [1 ]
Latifi, Rifat [1 ]
Friese, Randall [1 ]
Rhee, Peter [1 ]
机构
[1] Univ Arizona, Dept Surg, Tucson, AZ 85719 USA
关键词
INJURIES; TRAUMA; ACCURACY; ARTERIAL;
D O I
10.1007/s00268-012-1871-y
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Advances in technology have allowed for continuous noninvasive hemoglobin monitoring (SpHb), which may enable earlier detection of hemorrhage and more efficient surgical and/or blood transfusion management. The use of SpHb has not been described in the trauma population. The purpose of the present study was to evaluate the accuracy of a SpHb measurement device in severely injured trauma patients. Methods We performed a prospective cohort analysis of severely injured trauma patients admitted to the intensive care unit (ICU) at our level I trauma center over a 6 month period. Serial IHb (invasive hemoglobin) levels and SpHb for the first 72 h were measured. Each SpHb measurement was matched with a corresponding IHb measurement. We defined normal Hgb as[8 mg/dL and low Hgb as <8 mg/dL. Data were then grouped based on Hgb level. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and Spearman correlation coefficient plot were calculated. Results A total of 23 trauma patients with 89 data pairs were reviewed. Eighty-six percent of the patients were male with a mean age of 32 years and a mean injury severity score (ISS) of 21.1 +/- 14. Invasive hemoglobin had a range of 7.2-16.9 and SpHb had a range of 3.3-15.2. The average mean and difference between IHb and SpHb were 10.7 and 1, respectively. Continuous noninvasive hemoglobin measurement did not record data points 13.5 % of the time. The Spearman correlation plot revealed a correlation of R = 0.670 (p < 0.001). After dichotomization with Hgb > 8, SpHb was found to have a sensitivity of 91 %, PPV 96 %, specificity 40 %, NPV 20 %, and an accuracy of 88 %. Conclusions The continuous noninvasive hemoglobin monitor does not appear to represent serum hemoglobin levels accurately in severely injured trauma patients. However, we were able to identify utility for this noninvasive tool when Hgb was dichotomized into normal or low levels.
引用
收藏
页码:525 / 529
页数:5
相关论文
共 50 条
  • [41] The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution
    Macknet, Mark R.
    Allard, Martin
    Applegate, Richard L.
    Rook, James
    ANESTHESIA AND ANALGESIA, 2010, 111 (06): : 1424 - 1426
  • [42] Exclusion of Palliative Care From Hospital Mortality Rates: Not Ready for Prime Time
    Olmsted, Murrey G.
    Drozd, Edward M.
    Murphy, Joe
    JOURNAL OF PAIN AND SYMPTOM MANAGEMENT, 2010, 40 (06) : 926 - 928
  • [43] The accuracy of continuous noninvasive measurement of hemoglobin via pulse co-oximetry in patients undergoing knee arthroplasty
    Garcia Alvarez, Raquel
    Abad Motos, Ane
    Stolle Duenas, David
    Gonzalez Montero, Lucio
    Calvo Vecino, Jose Maria
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 109 - 110
  • [44] Editorial commentary: Are cytokines ready for prime time? Insights from markers and trials
    Nikolova, Andriana R.
    Shaw, Robin M.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2018, 28 (06) : 380 - 381
  • [45] Personalised antiplatelet therapy: are we ready for prime time? Data from China
    Li, Jianping
    Huo, Yong
    EUROINTERVENTION, 2013, 9 (03) : 296 - 298
  • [46] Continuous noninvasive Pulse Transit Time Measurement for Psycho-physiological Stress Monitoring
    Hey, Stefan
    Gharbi, Adnene
    von Haaren, Birte
    Walter, Katrin
    Koenig, Nils
    Loeffler, Simone
    INTERNATIONAL CONFERENCE ON EHEALTH, TELEMEDICINE, AND SOCIAL MEDICINE: ETELEMED 2009, PROCEEDINGS, 2009, : 113 - +
  • [47] A Pulse Transit Time Based Fusion Method for the Noninvasive and Continuous Monitoring of Respiratory Rate
    Ding, Xiao-Rong
    Zhang, Yuan-Ting
    Tsang, Hon Ki
    Karlen, Walter
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4240 - 4243
  • [48] CONTINUOUS NONINVASIVE CARDIAC-OUTPUT AS ESTIMATED FROM THE PULSE CONTOUR CURVE
    GRATZ, I
    KRAIDIN, J
    JACOBI, AG
    DECASTRO, NG
    SPAGNA, P
    LARIJANI, GE
    JOURNAL OF CLINICAL MONITORING, 1992, 8 (01): : 20 - 27
  • [49] CONTINUOUS, REAL-TIME, NONINVASIVE MONITOR OF BLOOD-PRESSURE - PENAZ METHODOLOGY APPLIED TO THE FINGER
    BOEHMER, RD
    JOURNAL OF CLINICAL MONITORING, 1987, 3 (04): : 282 - 287
  • [50] Ready for PRIME time: What we can learn from the Wyoming and friends experience
    Patel, Nachiket J.
    Heuser, Richard R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (03) : 455 - 456