Continuous Noninvasive Hemoglobin Monitor from Pulse Ox: Ready for Prime Time?

被引:23
|
作者
Joseph, Bellal [1 ]
Hadjizacharia, Pantelis [1 ]
Aziz, Hassan [1 ]
Snyder, Kara [1 ]
Wynne, Julie [1 ]
Kulvatunyou, Narong [1 ]
Tang, Andrew [1 ]
O'Keeffe, Terence [1 ]
Latifi, Rifat [1 ]
Friese, Randall [1 ]
Rhee, Peter [1 ]
机构
[1] Univ Arizona, Dept Surg, Tucson, AZ 85719 USA
关键词
INJURIES; TRAUMA; ACCURACY; ARTERIAL;
D O I
10.1007/s00268-012-1871-y
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Advances in technology have allowed for continuous noninvasive hemoglobin monitoring (SpHb), which may enable earlier detection of hemorrhage and more efficient surgical and/or blood transfusion management. The use of SpHb has not been described in the trauma population. The purpose of the present study was to evaluate the accuracy of a SpHb measurement device in severely injured trauma patients. Methods We performed a prospective cohort analysis of severely injured trauma patients admitted to the intensive care unit (ICU) at our level I trauma center over a 6 month period. Serial IHb (invasive hemoglobin) levels and SpHb for the first 72 h were measured. Each SpHb measurement was matched with a corresponding IHb measurement. We defined normal Hgb as[8 mg/dL and low Hgb as <8 mg/dL. Data were then grouped based on Hgb level. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and Spearman correlation coefficient plot were calculated. Results A total of 23 trauma patients with 89 data pairs were reviewed. Eighty-six percent of the patients were male with a mean age of 32 years and a mean injury severity score (ISS) of 21.1 +/- 14. Invasive hemoglobin had a range of 7.2-16.9 and SpHb had a range of 3.3-15.2. The average mean and difference between IHb and SpHb were 10.7 and 1, respectively. Continuous noninvasive hemoglobin measurement did not record data points 13.5 % of the time. The Spearman correlation plot revealed a correlation of R = 0.670 (p < 0.001). After dichotomization with Hgb > 8, SpHb was found to have a sensitivity of 91 %, PPV 96 %, specificity 40 %, NPV 20 %, and an accuracy of 88 %. Conclusions The continuous noninvasive hemoglobin monitor does not appear to represent serum hemoglobin levels accurately in severely injured trauma patients. However, we were able to identify utility for this noninvasive tool when Hgb was dichotomized into normal or low levels.
引用
收藏
页码:525 / 529
页数:5
相关论文
共 50 条
  • [21] Noninvasive prenatal diagnosis of fetal Rhesus D - Ready for prime(r) time
    Bianchi, DW
    Avent, ND
    Costa, JM
    van der Schoot, CE
    OBSTETRICS AND GYNECOLOGY, 2005, 106 (04): : 841 - 844
  • [22] Noninvasive measurement of continuous hemoglobin concentration via pulse CO-Oximetry
    Macknet, Mark R.
    Norton, Suzanne
    Kimball-Jones, Penny L.
    Applegate, Richard L.
    Martin, Robert D.
    Allard, Martin W.
    CHEST, 2007, 132 (04) : 493S - 494S
  • [23] Electrocardiography monitor alarms: Is customization of alarms ready for prime time in an intensive care setting?
    Albert, Nancy M.
    HEART & LUNG, 2018, 47 (05): : 509 - 510
  • [24] Capillary electrophoresis for the screening and diagnosis of inherited hemoglobin disorders. Ready for prime time?
    Lippi, Giuseppe
    Plebani, Mario
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (01) : 5 - 6
  • [25] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [26] On rendering continuous glucose monitoring ready for prime time in the cardiac care unit
    Rowen, Michaelanne
    Schneider, David J.
    Pratley, Richard E.
    Sobel, Burton E.
    CORONARY ARTERY DISEASE, 2007, 18 (05) : 405 - 409
  • [27] Noninvasive Tests for Prognosticating Outcomes in Patients With Chronic Liver Disease in Pregnancy: Ready for Prime Time?
    Kushner, Tatyana
    Sarkar, Monika
    Tran, Tram
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2019, 114 (02): : 209 - 211
  • [28] Noninvasive markers of fibrosis for longitudinal assessment of fibrosis in chronic liver disease: Are they ready for prime time?
    Thuluvath, PJ
    Krok, KL
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2005, 100 (09): : 1981 - 1983
  • [29] Noninvasive markers of fibrosis for longitudinal assessment of fibrosis in chronic liver disease: Are they ready for prime time?
    Thuluvath, Paul J.
    Krok, Karen L.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (07): : 1497 - 1499
  • [30] Fluid responsiveness assessment using the pulse oxymeter waveform: Not yet ready for prime time
    Cannesson, Maxime
    Desebbe, Olivier
    Lehot, Jean-Jacques
    ANESTHESIA AND ANALGESIA, 2007, 104 (06): : 1598 - 1599