Continuous Noninvasive Hemoglobin Monitor from Pulse Ox: Ready for Prime Time?

被引:23
|
作者
Joseph, Bellal [1 ]
Hadjizacharia, Pantelis [1 ]
Aziz, Hassan [1 ]
Snyder, Kara [1 ]
Wynne, Julie [1 ]
Kulvatunyou, Narong [1 ]
Tang, Andrew [1 ]
O'Keeffe, Terence [1 ]
Latifi, Rifat [1 ]
Friese, Randall [1 ]
Rhee, Peter [1 ]
机构
[1] Univ Arizona, Dept Surg, Tucson, AZ 85719 USA
关键词
INJURIES; TRAUMA; ACCURACY; ARTERIAL;
D O I
10.1007/s00268-012-1871-y
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Advances in technology have allowed for continuous noninvasive hemoglobin monitoring (SpHb), which may enable earlier detection of hemorrhage and more efficient surgical and/or blood transfusion management. The use of SpHb has not been described in the trauma population. The purpose of the present study was to evaluate the accuracy of a SpHb measurement device in severely injured trauma patients. Methods We performed a prospective cohort analysis of severely injured trauma patients admitted to the intensive care unit (ICU) at our level I trauma center over a 6 month period. Serial IHb (invasive hemoglobin) levels and SpHb for the first 72 h were measured. Each SpHb measurement was matched with a corresponding IHb measurement. We defined normal Hgb as[8 mg/dL and low Hgb as <8 mg/dL. Data were then grouped based on Hgb level. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and Spearman correlation coefficient plot were calculated. Results A total of 23 trauma patients with 89 data pairs were reviewed. Eighty-six percent of the patients were male with a mean age of 32 years and a mean injury severity score (ISS) of 21.1 +/- 14. Invasive hemoglobin had a range of 7.2-16.9 and SpHb had a range of 3.3-15.2. The average mean and difference between IHb and SpHb were 10.7 and 1, respectively. Continuous noninvasive hemoglobin measurement did not record data points 13.5 % of the time. The Spearman correlation plot revealed a correlation of R = 0.670 (p < 0.001). After dichotomization with Hgb > 8, SpHb was found to have a sensitivity of 91 %, PPV 96 %, specificity 40 %, NPV 20 %, and an accuracy of 88 %. Conclusions The continuous noninvasive hemoglobin monitor does not appear to represent serum hemoglobin levels accurately in severely injured trauma patients. However, we were able to identify utility for this noninvasive tool when Hgb was dichotomized into normal or low levels.
引用
收藏
页码:525 / 529
页数:5
相关论文
共 50 条
  • [31] Noninvasive Continuous Blood Pressure Estimation From Pulse Transit Time: A Review of the Calibration Models
    Barvik, Daniel
    Cerny, Martin
    Penhaker, Marek
    Noury, Norbert
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2022, 15 : 138 - 151
  • [32] Validation of continuous and noninvasive hemoglobin monitoring by pulse CO-oximetry in Japanese surgical patients
    Isosu, Tsuyoshi
    Obara, Shinju
    Hosono, Atsuyuki
    Ohashi, Satoshi
    Nakano, Yuko
    Imaizumi, Tsuyoshi
    Mogami, Midori
    Murakawa, Masahiro
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (01) : 55 - 60
  • [33] Noninvasive Continuous Blood Pressure Estimation with Peripheral Pulse Transit Time
    Li, Yibin
    Chen, Xiaomeng
    Zhang, Yang
    Deng, Ning
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 66 - 69
  • [34] Validation of continuous and noninvasive hemoglobin monitoring by pulse CO-oximetry in Japanese surgical patients
    Tsuyoshi Isosu
    Shinju Obara
    Atsuyuki Hosono
    Satoshi Ohashi
    Yuko Nakano
    Tsuyoshi Imaizumi
    Midori Mogami
    Masahiro Murakawa
    Journal of Clinical Monitoring and Computing, 2013, 27 : 55 - 60
  • [35] Accuracy of Noninvasive and Continuous Hemoglobin Measurement by Pulse Co-Oximetry During Preoperative Phlebotomy
    Dewhirst, Elisabeth
    Naguib, Aymen
    Winch, Peter
    Rice, Julie
    Galantowicz, Mark
    McConnell, Patrick
    Tobias, Joseph D.
    JOURNAL OF INTENSIVE CARE MEDICINE, 2014, 29 (04) : 238 - 242
  • [36] Pulse transit time as a derived noninvasive mean to monitor arterial distensibility changes in children
    J Y A Foo
    S J Wilson
    G Williams
    M-A Harris
    D Cooper
    Journal of Human Hypertension, 2005, 19 : 723 - 729
  • [37] Pulse transit time as a derived noninvasive mean to monitor arterial distensibility changes in children
    Foo, JYA
    Wilson, SJ
    Williams, G
    Harris, MA
    Cooper, D
    JOURNAL OF HUMAN HYPERTENSION, 2005, 19 (09) : 723 - 729
  • [38] Noninvasive ventilation for weaning in hypoxemic respiratory failure: not ready for prime time (vol 38, pg 1583, 2012)
    Laghi, Franco
    Fernandez, Rafael
    INTENSIVE CARE MEDICINE, 2013, 39 (01) : 162 - 162
  • [39] Noninvasive markers of hepatic fibrosis: Are they ready for prime time in the management of HIV/HCV co-infected patients?
    Zeremski, M
    Talal, AH
    JOURNAL OF HEPATOLOGY, 2005, 43 (01) : 2 - 5
  • [40] THE ACCURACY OF NONINVASIVE AND CONTINUOUS TOTAL HEMOGLOBIN MEASUREMENT BY PULSE CO-OXYMETRY UNDERGOING HEMODILUTIONAL AUTOLOGOUS TRANSFUSION
    Saito, J.
    Kitayama, M.
    Kudo, T.
    Hashimoto, H.
    Hirota, K.
    ANESTHESIA AND ANALGESIA, 2012, 114