Differentiation of liver abscess from liver metastasis using dual-energy spectral CT quantitative parameters

被引:22
|
作者
Wang, Nan [1 ]
Ju, Ye [1 ]
Wu, Jingjun [1 ]
Liu, Ailian [1 ]
Chen, Anliang [1 ]
Liu, Jinghong [1 ]
Liu, Yijun [1 ]
Li, Jianying [2 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Zhongshan Rd 222, Dalian, Peoples R China
[2] GE Healthcare, Shanghai, Peoples R China
关键词
Liver abscess; Liver metastasis; Differential diagnosis; HEPATIC-ABSCESS; DIFFUSION; MRI;
D O I
10.1016/j.ejrad.2019.02.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To explore the value of single source dual-energy spectral CT quantitative parameters in differential diagnosis of liver abscess and liver metastatic tumor. Methods: Fifty-one patients with 73 liver lesions (28 liver abscesses and 45 liver metastases) underwent plain and contrast-enhanced spectral CT scans. The fat and blood concentrations and CT values of 40-140 keV monochromatic images were measured to calculate effective atomic number (Eff-Z) and a slope (K): [CT(40 keV)-CT(140 keV)/100] for the cystic component on the plain scan images. The iodine concentration of the lesion wall on the enhanced three-phase images were measured and normalized to that of aorta for normalized iodine concentration (NIC). All of the single quantitative parameters were compared between liver abscesses and liver metastases by the independent samples t-test or Mann-Whitney U test. Statistical difference parameters between liver abscesses and liver metastases were analyzed by receiver-operating characteristic (ROC) curves. The diagnostic capability was determined by calculating the area under the curve (AUC). Using binary logistics regression analysis combining the best diagnostic performance parameter in the plain and enhanced phase images. The predictive model of liver abscess was established, and the receiver operating characteristic (ROC) analysis was performed. Results: There were significant differences in CT value, the slope (K), Eff-Z, blood and fat concentrations in the plain phase and NIC in the contrast-enhanced venous and delay phases between liver abscesses and liver metastases (all P < 0.05). The CT value at 40 keV in the plain phase provided 0.761 in area under the curve (AUC) in ROC with sensitivity of 71.4% and, specificity of 75.6% in differentiating liver abscess and tumor. Combining with NIC in delay phase, the respectively values improved to 0.963, and 89.3% and 93.3%. Conclusion: The quantitative parameters in single source dual-energy CT provide high diagnostic accuracy in differentiating liver abscesses from liver metastases.
引用
收藏
页码:204 / 208
页数:5
相关论文
共 50 条
  • [41] Quantification of liver extracellular volume using dual-energy CT: utility for prediction of liver-related events in cirrhosis
    Bak, Seongjun
    Kim, Ji Eun
    Bae, Kyungsoo
    Cho, Jae Min
    Choi, Ho Cheol
    Park, Mi Jung
    Choi, Hye Young
    Shin, Hwa Seon
    Lee, Sang Min
    Kim, Hyun Ok
    EUROPEAN RADIOLOGY, 2020, 30 (10) : 5317 - 5326
  • [42] Quantification of liver extracellular volume using dual-energy CT: utility for prediction of liver-related events in cirrhosis
    Seongjun Bak
    Ji Eun Kim
    Kyungsoo Bae
    Jae Min Cho
    Ho Cheol Choi
    Mi Jung Park
    Hye Young Choi
    Hwa Seon Shin
    Sang Min Lee
    Hyun Ok Kim
    European Radiology, 2020, 30 : 5317 - 5326
  • [43] Quantitative Dual-Energy CT and Crohn Disease
    Ohliger, Michael A.
    RADIOLOGY, 2021, 301 (01) : 152 - 153
  • [44] Assessment of Liver Fat: Dual-Energy CT versus Conventional CT with and without Contrast
    Xu, Jack Junchi
    Boesen, Mikkel Ranum
    Hansen, Sofie Lindskov
    Ulriksen, Peter Sommer
    Holm, Soren
    Lonn, Lars
    Hansen, Kristoffer Lindskov
    DIAGNOSTICS, 2022, 12 (03)
  • [45] Quantitative dual-energy CT techniques in the abdomen
    Toia, Giuseppe V.
    Mileto, Achille
    Wang, Carolyn L.
    Sahani, Dushyant V.
    ABDOMINAL RADIOLOGY, 2022, 47 (09) : 3003 - 3018
  • [46] Quantitative dual-energy CT techniques in the abdomen
    Giuseppe V. Toia
    Achille Mileto
    Carolyn L. Wang
    Dushyant V. Sahani
    Abdominal Radiology, 2022, 47 : 3003 - 3018
  • [47] The accuracy of bone mineral density measurement using dual-energy spectral CT and quantitative CT: a comparative phantom study
    Li, X.
    Li, J.
    Jiao, X.
    Jia, X.
    Zhang, X.
    Fan, G.
    Yang, J.
    Guo, J.
    CLINICAL RADIOLOGY, 2020, 75 (04) : 320.e9 - 320.e15
  • [48] Spectral Imaging of Iodine and Gadolinium Nanoparticles Using Dual-Energy CT
    Badea, C. T.
    Holbrook, M.
    Clark, D. P.
    Ghaghada, K.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [49] Differentiation of heroin and cocaine using dual-energy CT—an experimental study
    Jochen Grimm
    Ramona Wudy
    Edvard Ziegeler
    Stefan Wirth
    Michael Uhl
    Maximilian F. Reiser
    Michael Scherr
    International Journal of Legal Medicine, 2014, 128 : 475 - 482
  • [50] Differentiation of neoplastic from bland macroscopic portal vein thrombi using dual-energy spectral CT imaging: a pilot study
    Qian, Li Jun
    Zhu, Jiong
    Zhuang, Zhi Guo
    Xia, Qiang
    Cheng, Yu Fan
    Li, Jian Ying
    Xu, Jian Rong
    EUROPEAN RADIOLOGY, 2012, 22 (10) : 2178 - 2185