Differentiation of liver abscess from liver metastasis using dual-energy spectral CT quantitative parameters

被引:22
|
作者
Wang, Nan [1 ]
Ju, Ye [1 ]
Wu, Jingjun [1 ]
Liu, Ailian [1 ]
Chen, Anliang [1 ]
Liu, Jinghong [1 ]
Liu, Yijun [1 ]
Li, Jianying [2 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Zhongshan Rd 222, Dalian, Peoples R China
[2] GE Healthcare, Shanghai, Peoples R China
关键词
Liver abscess; Liver metastasis; Differential diagnosis; HEPATIC-ABSCESS; DIFFUSION; MRI;
D O I
10.1016/j.ejrad.2019.02.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To explore the value of single source dual-energy spectral CT quantitative parameters in differential diagnosis of liver abscess and liver metastatic tumor. Methods: Fifty-one patients with 73 liver lesions (28 liver abscesses and 45 liver metastases) underwent plain and contrast-enhanced spectral CT scans. The fat and blood concentrations and CT values of 40-140 keV monochromatic images were measured to calculate effective atomic number (Eff-Z) and a slope (K): [CT(40 keV)-CT(140 keV)/100] for the cystic component on the plain scan images. The iodine concentration of the lesion wall on the enhanced three-phase images were measured and normalized to that of aorta for normalized iodine concentration (NIC). All of the single quantitative parameters were compared between liver abscesses and liver metastases by the independent samples t-test or Mann-Whitney U test. Statistical difference parameters between liver abscesses and liver metastases were analyzed by receiver-operating characteristic (ROC) curves. The diagnostic capability was determined by calculating the area under the curve (AUC). Using binary logistics regression analysis combining the best diagnostic performance parameter in the plain and enhanced phase images. The predictive model of liver abscess was established, and the receiver operating characteristic (ROC) analysis was performed. Results: There were significant differences in CT value, the slope (K), Eff-Z, blood and fat concentrations in the plain phase and NIC in the contrast-enhanced venous and delay phases between liver abscesses and liver metastases (all P < 0.05). The CT value at 40 keV in the plain phase provided 0.761 in area under the curve (AUC) in ROC with sensitivity of 71.4% and, specificity of 75.6% in differentiating liver abscess and tumor. Combining with NIC in delay phase, the respectively values improved to 0.963, and 89.3% and 93.3%. Conclusion: The quantitative parameters in single source dual-energy CT provide high diagnostic accuracy in differentiating liver abscesses from liver metastases.
引用
收藏
页码:204 / 208
页数:5
相关论文
共 50 条
  • [21] Dual-energy CT quantitative parameters to evaluate occult peritoneal metastasis in advanced gastric cancer preoperatively
    Feng, Qiu-xia
    Zhu, Zhen-ning
    Li, Qiong
    Liu, Xi-sheng
    ABDOMINAL RADIOLOGY, 2024, 49 (10) : 3309 - 3318
  • [22] Accuracy of liver metastasis detection and characterization: Dual-energy CT versus single-energy CT with deep learning reconstruction
    Jensen, Corey T.
    Wong, Vincenzo K.
    Wagner-Bartak, Nicolaus A.
    Liu, Xinming
    Sobha, Renjith Padmanabhan Nair
    Sun, Jia
    Likhari, Gauruv S.
    Gupta, Shiva
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 168
  • [23] Dual-energy CT of liver metastases in patients with uveal melanoma
    Altenbernd, Jens
    Wetter, Axel
    Forsting, Michael
    Umutlu, Lale
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2016, 3 : 254 - 258
  • [24] Liver fibrosis assessment with multiphasic dual-energy CT: diagnostic performance of iodine uptake parameters
    Nagayama, Yasunori
    Kato, Yuki
    Inoue, Taihei
    Nakaura, Takeshi
    Oda, Seitaro
    Kidoh, Masafumi
    Ikeda, Osamu
    Hirai, Toshinori
    EUROPEAN RADIOLOGY, 2021, 31 (08) : 5779 - 5790
  • [25] Liver fibrosis assessment with multiphasic dual-energy CT: diagnostic performance of iodine uptake parameters
    Yasunori Nagayama
    Yuki Kato
    Taihei Inoue
    Takeshi Nakaura
    Seitaro Oda
    Masafumi Kidoh
    Osamu Ikeda
    Toshinori Hirai
    European Radiology, 2021, 31 : 5779 - 5790
  • [26] Iodine quantification to distinguish hepatic neuroendocrine tumor metastasis from hepatocellular carcinoma at dual-source dual-energy liver CT
    Kaltenbach, Benjamin
    Wichmann, Julian L.
    Pfeifer, Sophia
    Albrecht, Moritz H.
    Booz, Christian
    Lenga, Lukas
    Hammerstingl, Renate
    Dangelo, Tommaso
    Vogl, Thomas J.
    Martin, Simon S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 20 - 24
  • [27] The Role of Dual-Energy CT for the Assessment of Liver Metastasis Response to Treatment: Above the RECIST 1.1 Criteria
    Reginelli, Alfonso
    Del Canto, Mariateresa
    Clemente, Alfredo
    Gragnano, Eduardo
    Cioce, Fabrizio
    Urraro, Fabrizio
    Martinelli, Erika
    Cappabianca, Salvatore
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
  • [28] Quantitative assessment of iron in heart and liver phantoms using dual-energy computed tomography
    Tsai, Yi-Shan
    Chen, Jiang-Shiuh
    Wang, Chien-Kuo
    Lui, Chia-Hsing
    Cheng, Chao-Neng
    Kuo, Chin-Shun
    Liu, Yi-Sheng
    Tsai, Hong-Ming
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2014, 8 (03) : 907 - 912
  • [29] Differentiation of malignant from benign orbital tumours using dual-energy CT
    Luo, S.
    Sha, Y.
    Wu, J.
    Lin, N.
    Pan, Y.
    Zhang, F.
    Huang, W.
    CLINICAL RADIOLOGY, 2022, 77 (04) : 307 - 313
  • [30] Detection of fatty liver using virtual non-contrast dual-energy CT
    Zhang, Pengcheng Peter
    Choi, Hailey H.
    Ohliger, Michael A.
    ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2046 - 2056