Differentiation of liver abscess from liver metastasis using dual-energy spectral CT quantitative parameters

被引:22
|
作者
Wang, Nan [1 ]
Ju, Ye [1 ]
Wu, Jingjun [1 ]
Liu, Ailian [1 ]
Chen, Anliang [1 ]
Liu, Jinghong [1 ]
Liu, Yijun [1 ]
Li, Jianying [2 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Zhongshan Rd 222, Dalian, Peoples R China
[2] GE Healthcare, Shanghai, Peoples R China
关键词
Liver abscess; Liver metastasis; Differential diagnosis; HEPATIC-ABSCESS; DIFFUSION; MRI;
D O I
10.1016/j.ejrad.2019.02.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To explore the value of single source dual-energy spectral CT quantitative parameters in differential diagnosis of liver abscess and liver metastatic tumor. Methods: Fifty-one patients with 73 liver lesions (28 liver abscesses and 45 liver metastases) underwent plain and contrast-enhanced spectral CT scans. The fat and blood concentrations and CT values of 40-140 keV monochromatic images were measured to calculate effective atomic number (Eff-Z) and a slope (K): [CT(40 keV)-CT(140 keV)/100] for the cystic component on the plain scan images. The iodine concentration of the lesion wall on the enhanced three-phase images were measured and normalized to that of aorta for normalized iodine concentration (NIC). All of the single quantitative parameters were compared between liver abscesses and liver metastases by the independent samples t-test or Mann-Whitney U test. Statistical difference parameters between liver abscesses and liver metastases were analyzed by receiver-operating characteristic (ROC) curves. The diagnostic capability was determined by calculating the area under the curve (AUC). Using binary logistics regression analysis combining the best diagnostic performance parameter in the plain and enhanced phase images. The predictive model of liver abscess was established, and the receiver operating characteristic (ROC) analysis was performed. Results: There were significant differences in CT value, the slope (K), Eff-Z, blood and fat concentrations in the plain phase and NIC in the contrast-enhanced venous and delay phases between liver abscesses and liver metastases (all P < 0.05). The CT value at 40 keV in the plain phase provided 0.761 in area under the curve (AUC) in ROC with sensitivity of 71.4% and, specificity of 75.6% in differentiating liver abscess and tumor. Combining with NIC in delay phase, the respectively values improved to 0.963, and 89.3% and 93.3%. Conclusion: The quantitative parameters in single source dual-energy CT provide high diagnostic accuracy in differentiating liver abscesses from liver metastases.
引用
收藏
页码:204 / 208
页数:5
相关论文
共 50 条
  • [31] Detection of fatty liver using virtual non-contrast dual-energy CT
    Pengcheng Peter Zhang
    Hailey H. Choi
    Michael A. Ohliger
    Abdominal Radiology, 2022, 47 : 2046 - 2056
  • [32] Dual-energy CT quantitative parameters for the differentiation of benign from malignant lesions and the prediction of histopathological and molecular subtypes in breast cancer
    Wang, Xiaoxia
    Liu, Daihong
    Zeng, Xiangfei
    Jiang, Shixi
    Li, Lan
    Yu, Tao
    Zhang, Jiuquan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (05) : 1946 - 1957
  • [33] Dual-energy CT for liver iron quantification in patients with haematological disorders
    Werner, Sebastian
    Krauss, Bernhard
    Haberland, Ulrike
    Bongers, Malte
    Starke, Uwe
    Bakchoul, Tamam
    Enkel, Sigrid
    Nikolaou, Konstantin
    Horger, Marius
    EUROPEAN RADIOLOGY, 2019, 29 (06) : 2868 - 2877
  • [34] The value of a dual-energy spectral CT quantitative analysis technique in acute pancreatitis
    Hu, X.
    Wei, W.
    Zhang, L.
    CLINICAL RADIOLOGY, 2021, 76 (07) : 551.e11 - 551.e15
  • [35] Differentiating pulmonary metastasis from benign lung nodules in thyroid cancer patients using dual-energy CT parameters
    Ha, Taeho
    Kim, Wooil
    Cha, Jaehyung
    Lee, Young Hen
    Seo, Hyung Suk
    Park, So Young
    Kim, Nan Hee
    Hwang, Sung Ho
    Yong, Hwan Seok
    Oh, Yu-Whan
    Kang, Eun-Young
    Kim, Cherry
    EUROPEAN RADIOLOGY, 2022, 32 (03) : 1902 - 1911
  • [36] Differentiating pulmonary metastasis from benign lung nodules in thyroid cancer patients using dual-energy CT parameters
    Taeho Ha
    Wooil Kim
    Jaehyung Cha
    Young Hen Lee
    Hyung Suk Seo
    So Young Park
    Nan Hee Kim
    Sung Ho Hwang
    Hwan Seok Yong
    Yu-Whan Oh
    Eun-Young Kang
    Cherry Kim
    European Radiology, 2022, 32 : 1902 - 1911
  • [37] Noninvasive Staging of Liver Fibrosis with Dual-Energy CT: Close but No Cigar
    Chandarana, Hersh
    Shanbhogue, Krishna
    RADIOLOGY, 2021, 298 (03) : 609 - 610
  • [38] Quantification of liver iron content with CT—added value of dual-energy
    Michael A. Fischer
    Caecilia S. Reiner
    Dimitri Raptis
    Olivio Donati
    Robert Goetti
    Pierre-Alain Clavien
    Hatem Alkadhi
    European Radiology, 2011, 21 : 1727 - 1732
  • [39] Dual-energy CT for liver iron quantification in patients with haematological disorders
    Sebastian Werner
    Bernhard Krauss
    Ulrike Haberland
    Malte Bongers
    Uwe Starke
    Tamam Bakchoul
    Sigrid Enkel
    Konstantin Nikolaou
    Marius Horger
    European Radiology, 2019, 29 : 2868 - 2877
  • [40] Correction to: Liver fibrosis assessment with multiphasic dual-energy CT: diagnostic performance of iodine uptake parameters
    Yasunori Nagayama
    Yuki Kato
    Taihei Inoue
    Takeshi Nakaura
    Seitaro Oda
    Masafumi Kidoh
    Osamu Ikeda
    Toshinori Hirai
    European Radiology, 2021, 31 : 8823 - 8824