Evaluation of 3D Point Spread Function of a Semi-Ellipsoidal Ultrasound Computer Tomography System

被引:2
|
作者
Ruiter, N. V. [1 ]
Dapp, R. [1 ]
Zapf, M. [1 ]
Gemmeke, H. [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Data Proc & Elect, Karlsruhe, Germany
关键词
D O I
10.1109/ULTSYM.2011.0059
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design of 3DUSCT II was optimized with the aim of nearly isotropic and approx. spatially invariant 3D point spread function (PSF). To evaluate experimentally the 3DPSF, a thin wire was twisted into an irregular helix and imaged with the USCT system. The PSF was measured at 55 points along the wire as 2D profiles of the full width at half maximum (FWHM) in a plane perpendicular to the local direction of the thread. The mean FWHM over all profiles was 0.66 mm. The standard deviation (STD) of the FWHM profiles as measure of the isotropy had a mean of 0.18 mm. The variability of the mean FWHM over the points shows no systematic trend over the imaged space.
引用
收藏
页码:242 / 245
页数:4
相关论文
共 50 条
  • [31] 3D Breast Elastography with a Combined Ultrasound/Tomography System
    Booi, R. C.
    O'Donnell, M.
    Knoth, M. M.
    Xie, H.
    Rubin, J. M.
    Hall, A. L.
    Carson, P. L.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2056 - 2059
  • [32] Model-based pulse detection for 3D ultrasound computer tomography
    Schwarzenberg, G. F.
    Weber, M.
    Hopp, T.
    Ruiter, N. V.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1255 - 1258
  • [33] High-Speed Medical Imaging in 3D Ultrasound Computer Tomography
    Birk, Matthias
    Kretzek, Ernst
    Figuli, Peter
    Weber, Marc
    Becker, Juergen
    Ruiter, Nicole V.
    IEEE TRANSACTIONS ON PARALLEL AND DISTRIBUTED SYSTEMS, 2016, 27 (02) : 455 - 467
  • [34] Development and evaluation of a 3D ultrasound imaging system
    Tong, SD
    Cardinal, HN
    Downey, D
    Fenster, A
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 562 - 565
  • [35] Axial accuracy in localization microscopy with 3D point spread function engineering
    Siemons, Marijn E.
    Kapitein, Lukas C.
    Stallinga, Sjoerd
    OPTICS EXPRESS, 2022, 30 (16): : 28290 - 28300
  • [36] Simultaneous orientation and 3D localization microscopy with a Vortex point spread function
    Christiaan N. Hulleman
    Rasmus Ø. Thorsen
    Eugene Kim
    Cees Dekker
    Sjoerd Stallinga
    Bernd Rieger
    Nature Communications, 12
  • [37] Simultaneous orientation and 3D localization microscopy with a Vortex point spread function
    Hulleman, Christiaan N.
    Thorsen, Rasmus O.
    Kim, Eugene
    Dekker, Cees
    Stallinga, Sjoerd
    Rieger, Bernd
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [38] Ultrasensitive norovirus nanoimmunosensor based on concurrent axial super-localization of ellipsoidal point spread function by 3D light sheet microscopy
    Chakkarapani, Suresh Kumar
    Sun, Yucheng
    Kang, Seong Ho
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 284 : 81 - 90
  • [39] Evaluation of Transplant Kidneys Using a Novel Point of Care 3D Ultrasound System.
    Salinaro, J.
    Broder, J.
    Jaffa, E.
    Morgan, M.
    Vikraman-Sushama, D.
    Dahl, J.
    Herickhoff, C.
    Limkakeng, A.
    Peethumnongsin, E.
    Borawski, J.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2018, 18 : 823 - 823
  • [40] Microscope 3D Point Spread Function Evaluation Method on a Confirmed Object Plane Perpendicular to the Optical Axis
    Mao, Shuai
    Wang, Zhenzhou
    Pan, Jinfeng
    APPLIED SCIENCES-BASEL, 2020, 10 (07):