Model-based pulse detection for 3D ultrasound computer tomography

被引:3
|
作者
Schwarzenberg, G. F. [1 ]
Weber, M. [1 ]
Hopp, T. [1 ]
Ruiter, N. V. [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Data Proc & Elect, D-76021 Karlsruhe, Germany
关键词
D O I
10.1109/ULTSYM.2007.315
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
At Forschungszentrum Karlsruhe a 3D ultrasound computer tomograph (USCT) for breast cancer diagnosis is currently under development. For many applications, i.e. reconstruction of speed of sound maps, signal denoising,signal compression and calibration, it is necessary to detect pulses and their parameters (center frequency, bandwidth factor, time of arrival, phase and amplitude) accurately and robustly. The pulse detection Is demanding due to low signal-to-noise ratios (SNR) caused by unfocused pulses from single emitters. Besides that angle dependent pulse shapes result in ultrasonic echoes which are similar in their center frequency but vary strongly in their bandwidth factor. Additionally, in sum 3.5 million A-scans (20 GB) are acquired, so that the pulse detection has to be fast and efficient. This is achieved by using a fast pre-classifier in order to separate the ultrasonic echoes from the non-white system noise of our system. The detected echoes are then passed individually to a parameter estimation method to determine pulse parameters accurately. An analysis of several classifiers resulted in an alternating decision tree which is both fast and accurate. Classification performance of 95% could be achieved as well as robust parameter estimation with non-White system noise if the SNR is larger than 3 dB. A comparative image reconstruction resulted in significantly sharper images.
引用
收藏
页码:1255 / 1258
页数:4
相关论文
共 50 条
  • [1] Temperature model for 3D ultrasound computer tomography
    Zapf, M.
    Menshikov, A.
    Ruiter, N. V.
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [2] Model-Based Segmentation and Fusion of 3D Computed Tomography and 3D Ultrasound of the Eye for Radiotherapy Planning
    Cuadra, M. Bach
    Gorthi, S.
    Karahanoglu, F. I.
    Paquier, B.
    Pica, A.
    Do, H. P.
    Balmer, A.
    Munier, F.
    Thiran, J. -Ph.
    [J]. COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING: RECENT TRENDS, 2011, 19 : 247 - 263
  • [3] Glasses for 3D Ultrasound Computer Tomography
    Zapf, M.
    Ruiter, N. V.
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 820 - 823
  • [4] Model-based multiscale detection of 3D vessels
    Krissian, K
    Malandain, G
    Ayache, N
    Vaillant, R
    Trousset, Y
    [J]. 1998 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1998, : 722 - 727
  • [5] Aperture optimization for 3D ultrasound computer tomography
    Schwarzenberg, G. F.
    Zapf, M.
    Ruiter, N. V.
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1820 - 1823
  • [6] 3D ultrasound computer tomography for medical imaging
    Gemmeke, H.
    Ruiter, N. V.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1057 - 1065
  • [7] An Improved 3D Ultrasound Computer Tomography System
    Gemmeke, H.
    Dapp, R.
    Hopp, T.
    Zapf, M.
    Ruiter, N. V.
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1009 - 1012
  • [8] 3D Neural Model-Based Stopped Object Detection
    Maddalena, Lucia
    Petrosino, Alfredo
    [J]. IMAGE ANALYSIS AND PROCESSING - ICIAP 2009, PROCEEDINGS, 2009, 5716 : 585 - +
  • [9] Model-based detection of tubular structures in 3D images
    Krissian, K
    Malandain, G
    Ayache, N
    Vaillant, R
    Trousset, Y
    [J]. COMPUTER VISION AND IMAGE UNDERSTANDING, 2000, 80 (02) : 130 - 171
  • [10] Finite Element Model of Transducer Array Systems for 3D Ultrasound Computer Tomography
    Kohout, B.
    Goebel, G.
    Ruiter, Nicole V.
    [J]. MEDICAL IMAGING 2011: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2011, 7968