Aperture optimization for 3D ultrasound computer tomography

被引:18
|
作者
Schwarzenberg, G. F. [1 ]
Zapf, M. [1 ]
Ruiter, N. V. [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Data Proc & Elect, D-76021 Karlsruhe, Germany
关键词
D O I
10.1109/ULTSYM.2007.458
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
At Forschungszentrum Karlsruhe an ultrasound computer tomograph is developed for breast imaging in 3D. The aim of this project is the support of early diagnosis of breast cancer. Our current setup consists of a cylindrical tank assembled with 384 emitter and 1536 receiver elements which are grouped to 48 rectangular transducer array systems (TAS). It has been shown in previous work that the cylindrical aperture has major drawbacks in the vertical resolution. Given a new square TAS pattern with 4 emitters and 9 receivers, a new aperture for 160 TAS is derived which optimizes the image quality regarding three criteria. The optimization criteria regard the resolution of this 3D imaging system, the image contrast and utilization of the available ultrasound energy. An optimization with equal weighting of these criteria resulted in an 40% improvement of the resolution regarding the size and isotropy compared to the current cylindrical aperture. The resolution could be improved by 40% regarding the size and isotropy. Yet the contrast is degraded by 13%. Further work will be to find a reasonable weighting of the the three criteria. It could be shown that the presented method for aperture optimization makes this high-dimensional optimization problem feasible. The most important physical parameters like tissue attenuation, beam profile and scatterer profile, could be included to increase the authenticity of the results.
引用
下载
收藏
页码:1820 / 1823
页数:4
相关论文
共 50 条
  • [1] Optimization of the aperture and the transducer characteristics of a 3D Ultrasound Computer Tomography System
    Ruiter, Nicole V.
    Zapf, Michael
    Hopp, Torsten
    Dapp, Robin
    Gemmeke, Hartmut
    MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
  • [2] Glasses for 3D Ultrasound Computer Tomography
    Zapf, M.
    Ruiter, N. V.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 820 - 823
  • [3] Synthetic Aperture Focusing in 3D Ultrasound Transmission Tomography
    Jirik, R.
    Peterlik, I
    Fousek, J.
    Kratochvila, J.
    Jan, J.
    Zapf, M.
    Ruiter, N., V
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2010, : 405 - 408
  • [4] 3D ultrasound computer tomography for medical imaging
    Gemmeke, H.
    Ruiter, N. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1057 - 1065
  • [5] An Improved 3D Ultrasound Computer Tomography System
    Gemmeke, H.
    Dapp, R.
    Hopp, T.
    Zapf, M.
    Ruiter, N. V.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1009 - 1012
  • [6] Temperature model for 3D ultrasound computer tomography
    Zapf, M.
    Menshikov, A.
    Ruiter, N. V.
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [7] First in vivo results with 3D Ultrasound Computer Tomography
    Ruiter, N. V.
    Zapf, M.
    Dapp, R.
    Hopp, T.
    Gemmeke, H.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,
  • [8] Glasses for 3D Ultrasound Computer Tomography: Phase compensation
    Zapf, M.
    Hopp, T.
    Ruiter, N. V.
    MEDICAL IMAGING 2016: IMAGE PROCESSING, 2016, 9784
  • [9] 3D Ultrasound Computer Tomography for Breast Cancer Diagnosis
    Balzer, M.
    Birk, M.
    Dapp, R.
    Gemmeke, H.
    Kretzek, E.
    Menshikov, S.
    Zapf, M.
    Ruiter, N. V.
    2012 18TH IEEE-NPSS REAL TIME CONFERENCE (RT), 2012,
  • [10] 3D ultrasound computer tomography:: Data acquisition hardware
    Müller, TO
    Stotzka, R
    Ruiter, NV
    Schlote-Holubek, K
    Gemmeke, H
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2788 - 2792