Optimized energy thresholds in a spectral computed tomography scan for contrast agent imaging

被引:2
|
作者
Huang, Kai-Xin [1 ,2 ]
Deng, Zhi [1 ,2 ]
Xu, Xiao-Fei [1 ,2 ]
Xing, Yu-Xiang [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Key Lab Particle & Radiat Imaging, Minist Educ, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Spectral CT; Contrast agent imaging; Cramer-Rao lower bound; Thresholds optimization; K-edge; RAY; CT;
D O I
10.1007/s41365-019-0563-9
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Spectral computed tomography (CT) based on photon counting detectors (PCDs) is a well-researched topic in the field of X-ray imaging. When PCD is applied in a spectral CT system, the PCD energy thresholds must be carefully selected, especially for K-edge imaging, which is an important spectral CT application. This paper presents a threshold selection method that yields better-quality images in K-edge imaging. The main idea is to optimize the energy thresholds ray-by-ray according to the targeted component coefficients, followed by obtaining an overall optimal energy threshold by frequency voting. A low-dose pre-scan is used in practical implementations to estimate the line integrals of the component coefficients for the basis functions. The variance of the decomposed component coefficients is then minimized using the Cramer-Rao lower bound method with respect to the energy thresholds. The optimal energy thresholds are then used to take a full scan and gain better image reconstruction with less noise than would be given by a full scan using the non-optimal energy thresholds. Simulations and practical experiments on imaging iodine and gadolinium solutions, which are commonly used as contrast agents in medical applications, were used to validate the method. The noise was significantly reduced with the same dose relative to the non-optimal energy thresholds in both simulations and in practical experiments.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Evaluation of Tumor Microenvironment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging
    Ghaghada, Ketan B.
    Badea, Cristian T.
    Karumbaiah, Lohitash
    Fettig, Nicole
    Bellamkonda, Ravi V.
    Johnson, G. A.
    Annapragada, Ananth
    ACADEMIC RADIOLOGY, 2011, 18 (01) : 20 - 30
  • [42] A Plasmonic Supramolecular Nanohybrid as a Contrast Agent for Site-Selective Computed Tomography Imaging of Tumor
    Bindra, Anivind Kaur
    Sreejith, Sivaramapanicker
    Prasad, Rajendra
    Gorain, Mahadeo
    Thomas, Rijil
    Jana, Deblin
    Nai, Mui Hoon
    Wang, Dongdong
    Tharayil, Abhimanyu
    Kundu, Gopal C.
    Srivastava, Rohit
    Thomas, Sabu
    Lim, Chwee Teck
    Zhao, Yanli
    ADVANCED FUNCTIONAL MATERIALS, 2022, 32 (12)
  • [43] Barley leaves mediated biosynthesis of Au nanomaterials as a potential contrast agent for computed tomography imaging
    XUE Ni Chang
    ZHOU Chao Hui
    CHU Zhong Yun
    CHEN Li Na
    JIA Neng Qin
    Science China(Technological Sciences), 2021, (02) : 433 - 440
  • [44] Liposomes Coloaded with Iopamidol/Lipiodol as a RES-Targeted Contrast Agent for Computed Tomography Imaging
    Kweon, Soonjae
    Lee, Ho-Joon
    Hyung, Woo Jin
    Suh, Jinsuk
    Lim, Joon Seok
    Lim, Soo-Jeong
    PHARMACEUTICAL RESEARCH, 2010, 27 (07) : 1408 - 1415
  • [45] Integration of spectral computed tomography in arterial imaging
    Liu, Fuhe
    Yang, Wendong
    Liu, Jingzhe
    MINERVA CARDIOLOGY AND ANGIOLOGY, 2024,
  • [46] Liposomes Coloaded with Iopamidol/Lipiodol as a RES-Targeted Contrast Agent for Computed Tomography Imaging
    Soonjae Kweon
    Ho-Joon Lee
    Woo Jin Hyung
    Jinsuk Suh
    Joon Seok Lim
    Soo-Jeong Lim
    Pharmaceutical Research, 2010, 27 : 1408 - 1415
  • [47] Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging
    Si-Mohamed, Salim
    Thivolet, Arnaud
    Bonnot, Pierre-Emmanuel
    Bar-Ness, Daniel
    Kepenekian, Vahan
    Cormode, David P.
    Douek, Philippe
    Rousset, Pascal
    INVESTIGATIVE RADIOLOGY, 2018, 53 (10) : 629 - 639
  • [48] Incidence of contrast-induced nephropathy after a computed tomography scan
    Barrios Lopez, A.
    Garcia Martinez, F.
    Rodriguez, J., I
    Montero-San-Martin, B.
    Gomez Rioja, R.
    Diez, J.
    Martin-Hervas, C.
    RADIOLOGIA, 2021, 63 (04): : 307 - 313
  • [49] Dual imaging agent for magnetic particle imaging and computed tomography
    Liu, Sitong
    Heshmat, Anahita
    Andrew, Jennifer
    Barreto, Izabella
    Rinaldi-Ramos, Carlos M. M.
    NANOSCALE ADVANCES, 2023, 5 (11): : 3018 - 3032
  • [50] Dual-Energy Computed Tomography Imaging of Atherosclerotic Plaques in a Mouse Model Using a Liposomal-Iodine Nanoparticle Contrast Agent
    Bhavane, Rohan
    Badea, Cristian
    Ghaghada, Ketan B.
    Clark, Darin
    Vela, Deborah
    Moturu, Anoosha
    Annapragada, Akshaya
    Johnson, G. Allan
    Willerson, James T.
    Annapragada, Ananth
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (02) : 285 - 294