Posterior Glenoid Wear in Total Shoulder Arthroplasty: Eccentric Anterior Reaming Is Superior to Posterior Augment

被引:26
|
作者
Wang, Tim [1 ]
Abrams, Geoffrey D. [1 ,2 ]
Behn, Anthony W. [1 ]
Lindsey, Derek [2 ]
Giori, Nicholas [2 ]
Cheung, Emilie V. [1 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA 94063 USA
[2] Vet Affairs Palo Alto Hlth Care Syst, Ctr Tissue Regenerat Repair & Restorat, Palo Alto, CA USA
关键词
TOTAL KNEE ARTHROPLASTY; BONE DEFICIENCY; WEDGE AUGMENTATION; COMPONENTS; EROSION; OSTEOARTHRITIS; RETROVERSION; MANAGEMENT; FIXATION; DESIGN;
D O I
10.1007/s11999-015-4482-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Uncorrected glenoid retroversion during total shoulder arthroplasty may lead to an increased likelihood of glenoid prosthetic loosening. Augmented glenoid components seek to correct retroversion to address posterior glenoid bone loss, but few biomechanical studies have evaluated their performance. Questions/purposes We compared the use of augmented glenoid components with eccentric reaming with standard glenoid components in a posterior glenoid wear model. The primary outcome for biomechanical stability in this model was assessed by (1) implant edge displacement in superior and inferior edge loading at intervals up to 100,000 cycles, with secondary outcomes including (2) implant edge load during superior and inferior translation at intervals up to 100,000 cycles, and (3) incidence of glenoid fracture during implant preparation and after cyclic loading. Methods A 12A degrees-posterior glenoid defect was created in 12 composite scapulae, and the specimens were divided in two equal groups. In the posterior augment group, glenoid version was corrected to 8A degrees and an 8A degrees-augmented polyethylene glenoid component was placed. In the eccentric reaming group, anterior glenoid reaming was performed to neutral version and a standard polyethylene glenoid component was placed. Specimens were cyclically loaded in the superoinferior direction to 100,000 cycles. Superior and inferior glenoid edge displacements were recorded. Results Surviving specimens in the posterior augment group showed greater displacement than the eccentric reaming group of superior (1.01 +/- 0.02 [95% CI, 0.89-1.13] versus 0.83 +/- 0.10 [95% CI, 0.72-0.94 mm]; mean difference, 0.18 mm; p = 0.025) and inferior markers (1.36 +/- 0.05 [95% CI, 1.24-1.48] versus 1.20 +/- 0.09 [95% CI, 1.09-1.32 mm]; mean difference, 0.16 mm; p = 0.038) during superior edge loading and greater displacement of the superior marker during inferior edge loading (1.44 +/- 0.06 [95% CI, 1.28-1.59] versus 1.16 +/- 0.11 [95% CI, 1.02-1.30 mm]; mean difference, 0.28 mm; p = 0.009) at 100,000 cycles. No difference was seen with the inferior marker during inferior edge loading (0.93 +/- 0.15 [95% CI, 0.56-1.29] versus 0.78 +/- 0.06 [95% CI, 0.70-0.85 mm]; mean difference, 0.15 mm; p = 0.079). No differences in implant edge load were seen during superior and inferior loading. There were no instances of glenoid vault fracture in either group during implant preparation; however, a greater number of specimens in the eccentric reaming group were able to achieve the final 100,000 time without catastrophic fracture than those in the posterior augment group. Conclusions When addressing posterior glenoid wear in surrogate scapula models, use of angle-backed augmented glenoid components results in accelerated implant loosening compared with neutral-version glenoid after eccentric reaming, as shown by increased implant edge displacement at analogous times.
引用
收藏
页码:3928 / 3936
页数:9
相关论文
共 50 条
  • [41] Posterior glenoid rim deficiency in recurrent (atraumatic) posterior shoulder instability
    Weishaupt, D
    Zanetti, M
    Nyffeler, RW
    Gerber, C
    Hodler, J
    SKELETAL RADIOLOGY, 2000, 29 (04) : 204 - 210
  • [42] Comparative analysis of work-related outcomes in hemiarthroplasty with concentric glenoid reaming and total shoulder arthroplasty
    Gowd, Anirudh K.
    Garcia, Grant H.
    Liu, Joseph N.
    Malaret, Marissa R.
    Cabarcas, Brandon C.
    Romeo, Anthony A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (02) : 244 - 251
  • [43] Total shoulder arthroplasty for glenohumeral arthritis associated with posterior glenoid bone loss: results of an all-polyethylene, posteriorly augmented glenoid component
    Favorito, Paul J.
    Freed, Robert J.
    Passanise, Angela M.
    Brown, Maggie Jane
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (10) : 1681 - 1689
  • [44] Static posterior humeral head subluxation and total shoulder arthroplasty
    Gerber, Christian
    Costouros, John G.
    Sukthankar, Atut
    Fucentese, Sandro F.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (04) : 505 - 510
  • [45] POSTERIOR CAPSULORRHAPHY IN TOTAL SHOULDER ARTHROPLASTY - A CASE-REPORT
    NAMBA, RS
    THORNHILL, TS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (313) : 135 - 139
  • [46] GLENOID OSTEOTOMY FOR RECURRENT POSTERIOR DISLOCATION OF THE SHOULDER
    WILKINSON, JA
    THOMAS, WG
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (03): : 496 - 496
  • [47] Glenoid shape in atraumatic posterior instability of the shoulder
    Inui, H
    Sugamoto, K
    Miyamoto, T
    Yoshikawa, H
    Machida, A
    Hashimoto, J
    Nobuhara, K
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (403) : 87 - 92
  • [48] Chronic Locked Posterior Shoulder Dislocation Treated by Anatomical Total Shoulder Arthroplasty
    Popelka, V.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2016, 83 (01) : 55 - 61
  • [49] Posterior Bone Grafting for Glenoid Defects of the Shoulder
    Mulcahey, Mary K.
    Campbell, Kevin J.
    Golijanan, Petar
    Gross, Daniel
    Provencher, Matthew T.
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2015, 23 (01) : 32 - 42
  • [50] Treatment of locked posterior fracture-dislocations of the shoulder by total shoulder arthroplasty
    Cheng, SL
    Mackay, MB
    Richards, RR
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 1997, 6 (01) : 11 - 17