Posterior Glenoid Wear in Total Shoulder Arthroplasty: Eccentric Anterior Reaming Is Superior to Posterior Augment

被引:26
|
作者
Wang, Tim [1 ]
Abrams, Geoffrey D. [1 ,2 ]
Behn, Anthony W. [1 ]
Lindsey, Derek [2 ]
Giori, Nicholas [2 ]
Cheung, Emilie V. [1 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA 94063 USA
[2] Vet Affairs Palo Alto Hlth Care Syst, Ctr Tissue Regenerat Repair & Restorat, Palo Alto, CA USA
关键词
TOTAL KNEE ARTHROPLASTY; BONE DEFICIENCY; WEDGE AUGMENTATION; COMPONENTS; EROSION; OSTEOARTHRITIS; RETROVERSION; MANAGEMENT; FIXATION; DESIGN;
D O I
10.1007/s11999-015-4482-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Uncorrected glenoid retroversion during total shoulder arthroplasty may lead to an increased likelihood of glenoid prosthetic loosening. Augmented glenoid components seek to correct retroversion to address posterior glenoid bone loss, but few biomechanical studies have evaluated their performance. Questions/purposes We compared the use of augmented glenoid components with eccentric reaming with standard glenoid components in a posterior glenoid wear model. The primary outcome for biomechanical stability in this model was assessed by (1) implant edge displacement in superior and inferior edge loading at intervals up to 100,000 cycles, with secondary outcomes including (2) implant edge load during superior and inferior translation at intervals up to 100,000 cycles, and (3) incidence of glenoid fracture during implant preparation and after cyclic loading. Methods A 12A degrees-posterior glenoid defect was created in 12 composite scapulae, and the specimens were divided in two equal groups. In the posterior augment group, glenoid version was corrected to 8A degrees and an 8A degrees-augmented polyethylene glenoid component was placed. In the eccentric reaming group, anterior glenoid reaming was performed to neutral version and a standard polyethylene glenoid component was placed. Specimens were cyclically loaded in the superoinferior direction to 100,000 cycles. Superior and inferior glenoid edge displacements were recorded. Results Surviving specimens in the posterior augment group showed greater displacement than the eccentric reaming group of superior (1.01 +/- 0.02 [95% CI, 0.89-1.13] versus 0.83 +/- 0.10 [95% CI, 0.72-0.94 mm]; mean difference, 0.18 mm; p = 0.025) and inferior markers (1.36 +/- 0.05 [95% CI, 1.24-1.48] versus 1.20 +/- 0.09 [95% CI, 1.09-1.32 mm]; mean difference, 0.16 mm; p = 0.038) during superior edge loading and greater displacement of the superior marker during inferior edge loading (1.44 +/- 0.06 [95% CI, 1.28-1.59] versus 1.16 +/- 0.11 [95% CI, 1.02-1.30 mm]; mean difference, 0.28 mm; p = 0.009) at 100,000 cycles. No difference was seen with the inferior marker during inferior edge loading (0.93 +/- 0.15 [95% CI, 0.56-1.29] versus 0.78 +/- 0.06 [95% CI, 0.70-0.85 mm]; mean difference, 0.15 mm; p = 0.079). No differences in implant edge load were seen during superior and inferior loading. There were no instances of glenoid vault fracture in either group during implant preparation; however, a greater number of specimens in the eccentric reaming group were able to achieve the final 100,000 time without catastrophic fracture than those in the posterior augment group. Conclusions When addressing posterior glenoid wear in surrogate scapula models, use of angle-backed augmented glenoid components results in accelerated implant loosening compared with neutral-version glenoid after eccentric reaming, as shown by increased implant edge displacement at analogous times.
引用
收藏
页码:3928 / 3936
页数:9
相关论文
共 50 条
  • [31] Plication of the posterior capsule for intraoperative posterior instability during anatomic total shoulder arthroplasty
    Alentorn-Geli, Eduard
    Assenmacher, Andrew T.
    Sperling, John W.
    Cofield, Robert H.
    Sanchez-Sotelo, Joaquin
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (06) : 982 - 989
  • [32] Treatment Strategies for Chronic Glenoid Defects Following Anterior and Posterior Shoulder Dislocation
    Seebauer, Ludwig
    Goebel, Michael
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2008, 20 (06): : 500 - 510
  • [33] Anterior and posterior glenoid bone augmentation options for shoulder instability: state of the art
    Calvo, Emilio
    Itoi, Eiji
    Landreau, Philippe
    Arce, Guillermo
    Yamamoto, Nobuyuki
    Ma, Jie
    Sparavalo, Sara
    Wong, Ivan
    JOURNAL OF ISAKOS JOINT DISORDERS & ORTHOPAEDIC SPORTS MEDICINE, 2021, 6 (05) : 308 - 317
  • [34] Glenoid exposure in total shoulder arthroplasty
    Nove-Josserand, L.
    Clavert, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (01) : S129 - S135
  • [35] Glenoid replacement in total shoulder arthroplasty
    Keller, J
    Bak, S
    Bigliani, LU
    Levine, WN
    ORTHOPEDICS, 2006, 29 (03) : 221 - 226
  • [36] Glenoid exposure for total shoulder arthroplasty
    Katz, D
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (02): : 171 - 175
  • [37] Glenoid replacement in total shoulder arthroplasty
    Ibarra, C
    Dines, DM
    McLaughlin, JA
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (03) : 403 - +
  • [38] Comparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study
    Ko, Jia-Wei Kevin
    Syed, Usman Ali
    Barlow, Jonathan D.
    Paxton, Scott
    Loeffler, Bryan J.
    Thakar, Ocean
    Jamgochian, Grant
    Abboud, Joseph A.
    Getz, Charles L.
    Williams, Gerald R.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2019, 7 (04): : 307 - 313
  • [39] Posterior glenoid rim deficiency in recurrent (atraumatic) posterior shoulder instability
    Dominik Weishaupt
    Marco Zanetti
    Richard W. Nyffeler
    Christian Gerber
    J. Hodler
    Skeletal Radiology, 2000, 29 : 204 - 210
  • [40] Early clinical and radiographic outcomes of anatomic total shoulder arthroplasty with a biconvex posterior augmented glenoid for patients with posterior glenoid erosion: minimum 2-year follow-up
    Garrigues, Grant E.
    Quigley, Ryan J.
    Johnston, Peter S.
    Spencer, Edwin
    Walch, Gilles
    Neyton, Lionel
    Kelly, James
    Schrumpf, Mark
    Gillespie, Robert
    Sears, Benjamin W.
    Hatzidakis, Armodios M.
    Lau, Brian
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (08) : 1729 - 1737