Total shoulder arthroplasty for glenohumeral arthritis associated with posterior glenoid bone loss: results of an all-polyethylene, posteriorly augmented glenoid component

被引:35
|
作者
Favorito, Paul J. [1 ]
Freed, Robert J. [2 ]
Passanise, Angela M. [3 ]
Brown, Maggie Jane [1 ]
机构
[1] Wellington Orthopaed & Sports Med, 7575 Five Mile Rd, Wellington, OH 45230 USA
[2] Mayo Clin Hlth Syst Mankato, Mankato, MN USA
[3] Mercy Clin Orthoped Surg, Washington, MO USA
关键词
Augmented glenoid component; glenoid bone loss; shoulder arthroplasty; survival; PRIMARY OSTEOARTHRITIS; COMPUTED-TOMOGRAPHY; RETROVERSION; PROSTHESIS; DEFICIENCY; QUALITY; COMPLICATIONS; REPLACEMENT; DESIGNS; VERSION;
D O I
10.1016/j.jse.2016.02.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Posterior glenoid bone loss is commonly encountered in total shoulder arthroplasty (TSA). The purpose of our study is to report the clinical and radiographic findings of patients with a minimum of 2 years' follow-up treated with an all-polyethylene, augmented glenoid component. Methods: Twenty-two shoulders with posterior glenoid bone loss were treated by a single surgeon. All underwent primary TSA using a posteriorly augmented, all-polyethylene, stepped glenoid component. Outcome data included visual analog scale, Western Ontario Osteoarthritis of the Shoulder index, and Short Form 36 scores. Radiographic analysis was performed to evaluate bone-cement interface lucency, implant seating, and osseous integration of the central peg. Results: The mean follow-up period was 36 months. Average preoperative retroversion measured with computed tomography scan was 23.5 degrees. In addition to statistically significant increases in forward flexion and external rotation, the visual analog scale score, Western Ontario Osteoarthritis of the Shoulder score, and Short Form 36 physical component summary score all improved significantly (P<.001). Twelve shoulders had osseous integration between the central-peg flanges, 6 had bone adjacent to the central-peg flanges but without identifiable osseous integration, and 1 showed osteolysis. The mean Lazarus score was 0.5. All glenoids had perfect seating scores. Two patients sustained a total of 3 episodes of prosthetic instability. Conclusions: Early results of a posteriorly augmented, all-polyethylene, stepped prosthetic glenoid component to address posterior glenoid loss in TSA are encouraging. Continued evaluation will determine prosthetic longevity and maintained clinical improvement. (C) 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:1681 / 1689
页数:9
相关论文
共 50 条
  • [1] Clinical and Radiographic Outcomes of a Posteriorly Augmented Glenoid Component in Anatomic Total Shoulder Arthroplasty for Primary Osteoarthritis with Posterior Glenoid Bone Loss
    Ho, Jason C.
    Amini, Michael H.
    Entezari, Vahid
    Jun, Bong Jae
    Alolabi, Bashar
    Ricchetti, Eric T.
    Iannotti, Joseph P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (22): : 1934 - 1948
  • [2] Management of Glenoid Bone Loss With the Use of a New Augmented All-Polyethylene Glenoid Component
    Youderian, Ari R.
    Napolitano, Larry A.
    Davidson, Iyoosh U.
    Iannotti, Joseph P.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2012, 13 (04): : 163 - 169
  • [3] Total Shoulder Arthroplasty with an All-Polyethylene Pegged Bone-Ingrowth Glenoid Component A Clinical and Radiographic Outcome Study
    Wirth, Michael A.
    Loredo, Rebecca
    Garcia, Glen
    Rockwood, Charles A., Jr.
    Southworth, Carleton
    Iannotti, Joseph P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (03): : 260 - 267
  • [4] Total shoulder arthroplasty with an augmented component for anterior glenoid bone deficiency
    Lenart, Brett A.
    Namdari, Surena
    Williams, Gerald R.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (03) : 398 - 405
  • [5] Radiographic results of augmented allpolyethylene glenoids in the presence of posterior glenoid bone loss during total shoulder arthroplasty
    Stephens, Scott P.
    Spencer, Edwin E.
    Wirth, Michael A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (05) : 798 - 803
  • [6] Augmented glenoid component for bone deficiency in shoulder arthroplasty
    Rice, Robert S.
    Sperling, John W.
    Miletti, Joseph
    Schleck, Cathy
    Cofield, Robert H.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (03) : 579 - 583
  • [7] Shoulder Arthroplasty in the Presence of Posterior Glenoid Bone Loss
    Stephens, Scott P.
    Paisley, Kevin C.
    Jeng, Jeffrey
    Dutta, Anil K.
    Wirth, Michael A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (03): : 251 - 259
  • [8] The Use of a Custom Glenoid Component for the Treatment of Severe Glenoid Bone Loss in Reverse Total Shoulder Arthroplasty
    Berger, Neal M.
    Craig, Edward V.
    Petrigliano, Frank A.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2014, 15 (02): : 51 - 54
  • [9] Posterior glenoid bone grafting in total shoulder arthroplasty for osteoarthritis with severe posterior glenoid wear
    Nicholson, Gregory P.
    Cvetanovich, Gregory L.
    Rao, Allison J.
    O'Donnell, Patrick
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (10) : 1844 - 1853
  • [10] Total Shoulder Arthroplasty: Importance of the Thickness of the Polyethylene Glenoid Component
    Terrier, Alexandre
    Pioletti, Dominique
    Farron, Alain
    SWISS MEDICAL WEEKLY, 2011, 141 : 28S - 28S