The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography

被引:37
|
作者
Tatsugami, F. [1 ]
Matsuki, M. [1 ]
Nakai, G. [1 ]
Inada, Y. [1 ]
Kanazawa, S. [1 ]
Takeda, Y. [2 ]
Morita, H. [3 ]
Takada, H. [1 ]
Yoshikawa, S. [1 ]
Fukumura, K. [1 ]
Narumi, Y. [1 ]
机构
[1] Osaka Med Coll, Dept Radiol, Takatsuki, Osaka 5698686, Japan
[2] Osaka Med Coll, Dept Internal Med 1, Takatsuki, Osaka 5698686, Japan
[3] Osaka Med Coll, Dept Internal Med 3, Takatsuki, Osaka 5698686, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2012年 / 85卷 / 1016期
关键词
SPIRAL COMPUTED-TOMOGRAPHY; FILTERED BACK-PROJECTION; RECONSTRUCTION TECHNIQUE; NOISE-REDUCTION; CARDIAC CT; ACCURACY; VOLUME; ATTENUATION; EXPERIENCE; RESOLUTION;
D O I
10.1259/bjr/10084599
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the effect of adaptive iterative dose reduction (AIDR) on image noise and image quality as compared with standard filtered back projection (FBP) in 320-detector row CT coronary angiography (CTCA). Methods: 50 patients (14 females, mean age 68 +/- 9 years) who underwent CTCA (100 kV or 120 kV, 400-580mA) within a single heartbeat were enrolled. Studies were reconstructed with FBP and subsequently AIDR. Image noise, vessel contrast and contrast-to-noise ratio (CNR) in the coronary arteries were evaluated. Overall image quality for coronary arteries was assessed using a five-point scale (1, non-diagnostic; 5, excellent). Results: All the examinations were performed in a single heartbeat. Image noise in the aorta was significantly lower in data sets reconstructed with AIDR than in those reconstructed with FBP (21.4 +/- 3.1 HU vs 36.9 +/- 4.5 HU; p<0.001). No significant differences were observed between FBP and AIDR for the mean vessel contrast (HU) in the proximal coronary arteries. Consequently, CNRs in the proximal coronary arteries were higher in the AIDR group than in the FBP group (p<0.001). The mean image quality score was improved by AIDR (3.75 +/- 0.38 vs 4.24 +/- 0.38; p<0.001). Conclusion: The use of AIDR reduces image noise and improves image quality in 320-detector row CTCA.
引用
收藏
页码:E378 / E382
页数:5
相关论文
共 50 条
  • [41] Radiation dose reduction by adjusting bolus tracking parameters in a 320-detector row scanner
    Nishimura Matsumoto, Jacqueline Kioko
    Nascimento Assuncao, Antonildes, Jr.
    Dantas Junior, Roberto Nery
    Batista Araujo-Filho, Jose de Arimateia
    Andrade, Solange de Sousa
    Nomura, Cesar Higa
    Parga, Jose Rodrigues
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2018, 12 (04) : 312 - 315
  • [42] Quantification of coronary flow using dynamic angiography with 320-detector row CT: A new method for detecting ischemia for intermediate coronary stenosis
    Bai Mingjun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C38 - C38
  • [43] 320-Detector row CT angiography for detection and evaluation of intracranial aneurysms: Comparison with conventional digital subtraction angiography
    Wang, H.
    Li, W.
    He, H.
    Luo, L.
    Chen, C.
    Guo, Y.
    CLINICAL RADIOLOGY, 2013, 68 (01) : E15 - E20
  • [44] Prospective versus retrospective ECG gating for 320-detector CT of the coronary arteries: comparison of image quality and patient radiation dose
    Qin, Jie
    Liu, Ling-yun
    Meng, Xiao-chun
    Zhang, Jian-sheng
    Dong, Yun-xu
    Fang, Yuan
    Shan, Hong
    CLINICAL IMAGING, 2011, 35 (03) : 193 - 197
  • [45] KINEMATIC ANALYSIS OF SWALLOWING USING 320-DETECTOR ROW CT
    Inamoto, Yoko
    Fujii, N.
    Baba, M.
    Saitoh, E.
    Yoshioka, S.
    Okada, S.
    Yokoyama, M.
    Ozaki, K.
    Ida, Y.
    Nakai, T.
    Katada, K.
    DYSPHAGIA, 2009, 24 (04) : 467 - 467
  • [46] Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms
    Luo, Zhuren
    Wang, Dan
    Sun, Xilin
    Zhang, Tong
    Liu, Fang
    Dong, Dandan
    Chan, Nicholas K.
    Shen, Baozhong
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) : 118 - 122
  • [47] Image quality of virtual monochromatic images obtained using 320-detector row CT: A phantom study evaluating the effects of iterative reconstruction and body size
    Okamura, Teppei
    Yamada, Yoshitake
    Yamada, Minoru
    Yamazaki, Akihisa
    Shiraga, Nobuyuki
    Jinzaki, Masahiro
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 95 : 212 - 221
  • [48] Accuracy of 320-detector row nonsubtracted and subtracted volume CT angiography in evaluating small cerebral aneurysms
    Chen, Wenhua
    Xing, Wei
    He, Zhongming
    Peng, Ya
    Wang, Caoye
    Wang, Qi
    JOURNAL OF NEUROSURGERY, 2017, 127 (04) : 725 - 731
  • [49] Transluminal attenuation gradient on 320-detector row CT (TAG320) adds incremental value to coronary angiography for detection of functionally significant stenosis
    Wong, D. T. L.
    Ko, B. S.
    Cameron, J. D.
    Nerlekar, N.
    Leung, M. C. H.
    Malaiapan, Y.
    Crossett, M.
    Leong, D. P.
    Meredith, I. T.
    Seneviratne, S. K.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S2 - S2
  • [50] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Zhang, Chuanchen
    Zhang, Zhaoqi
    Yan, Zixu
    Xu, Lei
    Yu, Wei
    Wang, Rui
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07): : 1059 - 1068