The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography

被引:37
|
作者
Tatsugami, F. [1 ]
Matsuki, M. [1 ]
Nakai, G. [1 ]
Inada, Y. [1 ]
Kanazawa, S. [1 ]
Takeda, Y. [2 ]
Morita, H. [3 ]
Takada, H. [1 ]
Yoshikawa, S. [1 ]
Fukumura, K. [1 ]
Narumi, Y. [1 ]
机构
[1] Osaka Med Coll, Dept Radiol, Takatsuki, Osaka 5698686, Japan
[2] Osaka Med Coll, Dept Internal Med 1, Takatsuki, Osaka 5698686, Japan
[3] Osaka Med Coll, Dept Internal Med 3, Takatsuki, Osaka 5698686, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2012年 / 85卷 / 1016期
关键词
SPIRAL COMPUTED-TOMOGRAPHY; FILTERED BACK-PROJECTION; RECONSTRUCTION TECHNIQUE; NOISE-REDUCTION; CARDIAC CT; ACCURACY; VOLUME; ATTENUATION; EXPERIENCE; RESOLUTION;
D O I
10.1259/bjr/10084599
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the effect of adaptive iterative dose reduction (AIDR) on image noise and image quality as compared with standard filtered back projection (FBP) in 320-detector row CT coronary angiography (CTCA). Methods: 50 patients (14 females, mean age 68 +/- 9 years) who underwent CTCA (100 kV or 120 kV, 400-580mA) within a single heartbeat were enrolled. Studies were reconstructed with FBP and subsequently AIDR. Image noise, vessel contrast and contrast-to-noise ratio (CNR) in the coronary arteries were evaluated. Overall image quality for coronary arteries was assessed using a five-point scale (1, non-diagnostic; 5, excellent). Results: All the examinations were performed in a single heartbeat. Image noise in the aorta was significantly lower in data sets reconstructed with AIDR than in those reconstructed with FBP (21.4 +/- 3.1 HU vs 36.9 +/- 4.5 HU; p<0.001). No significant differences were observed between FBP and AIDR for the mean vessel contrast (HU) in the proximal coronary arteries. Consequently, CNRs in the proximal coronary arteries were higher in the AIDR group than in the FBP group (p<0.001). The mean image quality score was improved by AIDR (3.75 +/- 0.38 vs 4.24 +/- 0.38; p<0.001). Conclusion: The use of AIDR reduces image noise and improves image quality in 320-detector row CTCA.
引用
收藏
页码:E378 / E382
页数:5
相关论文
共 50 条
  • [31] Influence of hemodynamic parameters on coronary artery attenuation with 320-detector coronary CT angiography
    Tomizawa, Nobuo
    Komatsu, Shuhei
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (02) : 230 - 233
  • [32] Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography
    Tomizawa, Nobuo
    Komatsu, Shuhei
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (01): : 139 - 146
  • [33] Quantification of coronary flow using dynamic angiography with 320-detector row CT and motion coherence image processing: Detection of ischemia for intermediate coronary stenosis
    Nagao, Michinobu
    Yamasaki, Yuzo
    Kamitani, Takeshi
    Kawanami, Satoshi
    Sagiyama, Koji
    Yamanouchi, Torahiko
    Shimomiya, Yamato
    Matoba, Tetsuya
    Mukai, Yasushi
    Odashiro, Keita
    Baba, Shingo
    Maruoka, Yasuhiro
    Kitamura, Yoshiyuki
    Nishie, Akihiro
    Honda, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 996 - 1003
  • [34] Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography
    Nobuo Tomizawa
    Shuhei Komatsu
    Masaaki Akahane
    Rumiko Torigoe
    Shigeru Kiryu
    Kuni Ohtomo
    The International Journal of Cardiovascular Imaging, 2012, 28 : 139 - 146
  • [35] Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
    Yoneyama, Kihei
    Vavere, Andrea L.
    Cerci, Rodrigo
    Ahmed, Rukhsar
    Arai, Andrew E.
    Niinuma, Hiroyuki
    Rybicki, Frank J.
    Rochitte, Carlos E.
    Clouse, Melvin E.
    George, Richard T.
    Lima, Joao A. C.
    Arbab-Zadeh, Armin
    HEART INTERNATIONAL, 2012, 7 (02): : 51 - 56
  • [36] Effect of the Motion Correction Technique on Image Quality at 320-Detector Computed Tomography Coronary Angiography in Patients With Atrial Fibrillation
    Tatsugami, Fuminari
    Higaki, Toru
    Fukumoto, Wataru
    Kaichi, Yoko
    Iida, Makoto
    Fujioka, Chikako
    Kiguchi, Masao
    Kihara, Yasuki
    Awai, Kazuo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (04) : 603 - 608
  • [37] Fully Automated 3D-Coronary Endothelial Shear Stress Based on 320-Detector Row CT Angiography
    Rybicki, F.
    Mitsouras, D.
    Nallamshetty, L.
    Coskun, A.
    Feldman, C.
    Stone, P.
    Steigner, M.
    Chatzizisis, Y.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [38] Coronary computed tomography angiography and endocardial leads - Image quality in 320-row CT using iterative reconstruction
    Garmer, Marietta
    Bonsels, Marc
    Metz, Frauke
    Klein-Wiele, Oliver
    Brandts, Bodo
    Groenemeyer, Dietrich
    CLINICAL IMAGING, 2018, 50 : 157 - 163
  • [39] Cerebral Aneurysms: Accuracy of 320-Detector Row Nonsubtracted and Subtracted Volumetric CT Angiography for Diagnosis
    Chen, Wenhua
    Xing, Wei
    Peng, Ya
    He, Zhongming
    Wang, Caoye
    Wang, Qi
    RADIOLOGY, 2013, 269 (03) : 841 - 849
  • [40] Improved image quality of tube phantom simulating a coronary artery by averaging repeated scans using a 320-detector row CT scanner
    Fukuoka, Hidehiko
    Suzuki, Shogo
    Kono, Yasuhisa
    Shiotani, Seiji
    Kobayashi, Tomoya
    FORENSIC IMAGING, 2021, 24