The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography

被引:37
|
作者
Tatsugami, F. [1 ]
Matsuki, M. [1 ]
Nakai, G. [1 ]
Inada, Y. [1 ]
Kanazawa, S. [1 ]
Takeda, Y. [2 ]
Morita, H. [3 ]
Takada, H. [1 ]
Yoshikawa, S. [1 ]
Fukumura, K. [1 ]
Narumi, Y. [1 ]
机构
[1] Osaka Med Coll, Dept Radiol, Takatsuki, Osaka 5698686, Japan
[2] Osaka Med Coll, Dept Internal Med 1, Takatsuki, Osaka 5698686, Japan
[3] Osaka Med Coll, Dept Internal Med 3, Takatsuki, Osaka 5698686, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2012年 / 85卷 / 1016期
关键词
SPIRAL COMPUTED-TOMOGRAPHY; FILTERED BACK-PROJECTION; RECONSTRUCTION TECHNIQUE; NOISE-REDUCTION; CARDIAC CT; ACCURACY; VOLUME; ATTENUATION; EXPERIENCE; RESOLUTION;
D O I
10.1259/bjr/10084599
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the effect of adaptive iterative dose reduction (AIDR) on image noise and image quality as compared with standard filtered back projection (FBP) in 320-detector row CT coronary angiography (CTCA). Methods: 50 patients (14 females, mean age 68 +/- 9 years) who underwent CTCA (100 kV or 120 kV, 400-580mA) within a single heartbeat were enrolled. Studies were reconstructed with FBP and subsequently AIDR. Image noise, vessel contrast and contrast-to-noise ratio (CNR) in the coronary arteries were evaluated. Overall image quality for coronary arteries was assessed using a five-point scale (1, non-diagnostic; 5, excellent). Results: All the examinations were performed in a single heartbeat. Image noise in the aorta was significantly lower in data sets reconstructed with AIDR than in those reconstructed with FBP (21.4 +/- 3.1 HU vs 36.9 +/- 4.5 HU; p<0.001). No significant differences were observed between FBP and AIDR for the mean vessel contrast (HU) in the proximal coronary arteries. Consequently, CNRs in the proximal coronary arteries were higher in the AIDR group than in the FBP group (p<0.001). The mean image quality score was improved by AIDR (3.75 +/- 0.38 vs 4.24 +/- 0.38; p<0.001). Conclusion: The use of AIDR reduces image noise and improves image quality in 320-detector row CTCA.
引用
收藏
页码:E378 / E382
页数:5
相关论文
共 50 条
  • [21] Dose reduction at CT of the lumbar spine using a 320-detector row scanner: initial results
    Gervaise, A.
    Louis, M.
    Batch, T.
    Loeuille, D.
    Noel, A.
    Guillemin, F.
    Blum, A.
    JOURNAL DE RADIOLOGIE, 2010, 91 (7-8): : 779 - 785
  • [22] Subtraction Coronary CT Angiography for the Evaluation of Severely Calcified Lesions Using a 320-Detector Row Scanner
    Yoshioka K.
    Tanaka R.
    Current Cardiovascular Imaging Reports, 2011, 4 (6) : 437 - 446
  • [23] Diagnostic Accuracy of Noninvasive Coronary Angiography With 320-Detector Row Computed Tomography
    Nasis, Arthur
    Leung, Michael C.
    Antonis, Paul R.
    Cameron, James D.
    Lehman, Sam J.
    Hope, Sarah A.
    Crossett, Marcus P.
    Troupis, John M.
    Meredith, Ian T.
    Seneviratne, Sujith K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (10): : 1429 - 1435
  • [24] Patient radiation dose in prospectively gated axial CT coronary angiography and retrospectively gated helical technique with a 320-detector row CT scanner
    Seguchi, Shigenobu
    Aoyama, Takahiko
    Koyama, Shuji
    Fujii, Keisuke
    Yamauchi-Kawaura, Chiyo
    MEDICAL PHYSICS, 2010, 37 (11) : 5579 - 5585
  • [25] Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner
    Tomizawa, Nobuo
    Maeda, Eriko
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (07): : 1613 - 1618
  • [26] Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner
    Nobuo Tomizawa
    Eriko Maeda
    Masaaki Akahane
    Rumiko Torigoe
    Shigeru Kiryu
    Kuni Ohtomo
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1613 - 1618
  • [27] Submillisievert Median Radiation Dose for Coronary Angiography with a Second-Generation 320-Detector Row CT Scanner in 107 Consecutive Patients
    Chen, Marcus Y.
    Shanbhag, Sujata M.
    Arai, Andrew E.
    RADIOLOGY, 2013, 267 (01) : 76 - 85
  • [28] Radiation Dose of Second-Generation 320-Detector Row CT Response
    Chen, Marcus Y.
    Shanbhag, Sujata M.
    Arai, Andrew E.
    RADIOLOGY, 2013, 268 (03) : 928 - 928
  • [29] OPTIMAL HEART RATE ADJUSTMENT CONTRIBUTES TO THE IMAGE QUALITY IN HALF SCAN RECONSTRUCTION WITH 320-DETECTOR ROW COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY
    Sera, Fusako
    Fujita, Masashi
    Watanabe, Tetsuya
    Awata, Masaki
    Iida, Osamu
    Okamoto, Shin
    Ishihara, Takayuki
    Dohi, Tomoharu
    Mishima, Tsuyoshi
    Sato, Kei
    Nanto, Kiyonori
    Mizukami, Yukika
    Uematsu, Masaaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E164 - E164
  • [30] Quantification of coronary flow using dynamic angiography with 320-detector row CT and motion coherence image processing: Detection of ischemia for intermediate coronary stenosis
    Qin, Jie
    Cai, Songwang
    Quan, Li
    Tang, Wenjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C126 - C126