Ambient desorption/ionization mass spectrometry using a liquid sampling-atmospheric glow discharge (LS-APGD) ionization source

被引:35
|
作者
Marcus, R. Kenneth [1 ]
Burdette, Carolyn Q. [1 ]
Manard, Benjamin T. [1 ]
Zhang, Lynn X. [1 ]
机构
[1] Clemson Univ, Dept Chem, Clemson, SC 29634 USA
关键词
Liquid sampling-atmospheric pressure glow discharge; Microplasma; Ambient desorption/ionization; Mass spectrometry; OPTICAL-EMISSION SOURCE; REAL-TIME; CIGARETTE-SMOKE; ION-SOURCE; PLASMA; CATECHINS; DRUGS; EXTRACTS;
D O I
10.1007/s00216-013-7216-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel approach to ambient desorption/ionization mass spectrometry (ADI-MS) is described, based on a recently developed liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source. The device is essentially unmodified relative to its implementation in elemental mass spectrometry, where the operational space is characterized by low operation power (< 10 W) and low solution delivery rates (< 50 mu L min(-1)). In this implementation, the plasma is produced between a Ni anode and an electrolytic liquid (1 M HNO3) cathode flowing through a glass capillary that is angled towards the sample surface, at a distance of similar to 2 mm away. Analyte species can be desorbed/ionized from neat solution residues and complex solid samples. The ADI-LS-APGD source is mounted onto the source interface of a Thermo Finnigan LCQ Advantage Max quadrupole ion trap mass spectrometer without modifications to the instrument faceplate or ion optics. Described here is the initial evaluation of the roles of source geometry and working parameters, including electrolytic solution composition and plasma current, on the response of caffeine residues, with preliminary limits of detection based on the relative standard deviation of the spectral background suggested to be on the 10-pg level. Demonstrative spectra are presented for green tea extracts and raw leaves, coffee beans, a dried (raw) tobacco leaf, an analgesic tablet, and paper currency. Versatility is further revealed through the determination of components in common cigarette smoke. In each case, the spectra are characterized by (M + H)(+) species of the expected constituents. The capacity for a single source to perform both in solution and particulate elemental analysis (as shown previously) and ADI of molecular species is unique in the realm of mass spectrometry.
引用
收藏
页码:8171 / 8184
页数:14
相关论文
共 50 条
  • [11] Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source for Elemental Mass Spectrometry
    Marcus, R. Kenneth
    Quarles, C. Derrick, Jr.
    Barinaga, Charles J.
    Carado, Anthony J.
    Koppenaal, David W.
    ANALYTICAL CHEMISTRY, 2011, 83 (07) : 2425 - 2429
  • [12] Liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasmas for diverse spectrochemical analysis applications
    Marcus, R. Kenneth
    Manard, Benjamin T.
    Quarles, C. Derrick, Jr.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (04) : 704 - 716
  • [13] Preliminary Assessment of Potential for Metal-Ligand Speciation in Aqueous Solution via the Liquid Sampling-Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source: Uranyl Acetate
    Zhang, Lynn X.
    Manard, Benjamin T.
    Powell, Brian A.
    Marcus, R. Kenneth
    ANALYTICAL CHEMISTRY, 2015, 87 (14) : 7218 - 7225
  • [14] Roles of electrode material and geometry in liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma emission spectroscopy
    Quarles, C. Derrick, Jr.
    Manard, Benjamin T.
    Burdette, Carolyn Q.
    Marcus, R. Kenneth
    MICROCHEMICAL JOURNAL, 2012, 105 : 48 - 55
  • [15] Characterization of arsenic species by liquid sampling-atmospheric pressure glow discharge ionization mass spectrometry
    Goodwin, Joseph
    Marcus, R. Kenneth
    McRae, Garnet
    Sturgeon, Ralph E.
    Mester, Zoltan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (15) : 3585 - 3594
  • [16] Femtosecond laser ablation particle introduction to a liquid sampling-atmospheric pressure glow discharge ionization source
    Carado, Anthony J.
    Quarles, C. Derrick, Jr.
    Duffin, Andrew M.
    Barinaga, Charles J.
    Russo, Richard E.
    Marcus, R. Kenneth
    Eiden, Gregory C.
    Koppenaal, David W.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (03) : 385 - 389
  • [17] Microfabricated Glow Discharge Plasma (MFGDP) for Ambient Desorption/Ionization Mass Spectrometry
    Ding, Xuelu
    Zhan, Xuefang
    Yuan, Xin
    Zhao, Zhongjun
    Duan, Yixiang
    ANALYTICAL CHEMISTRY, 2013, 85 (19) : 9013 - 9020
  • [18] Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium
    Goodwin, Joseph V.
    Manard, Benjamin T.
    Ticknor, Brian W.
    Cable-Dunlap, Paula
    Marcus, R. Kenneth
    ANALYTICAL CHEMISTRY, 2023, 95 (32) : 12131 - 12138
  • [19] Diffusion, ionization, and sampling processes in the glow discharge source for mass spectrometry
    Hang, W
    Harrison, WW
    ANALYTICAL CHEMISTRY, 1997, 69 (24) : 4957 - 4963
  • [20] Computational model of a direct current glow discharge used as an ambient desorption/ionization source for mass spectrometry
    Ellis, Wade C.
    Spencer, Ross L.
    Reininger, Charlotte
    Farnsworth, Paul B.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) : 2407 - 2415