Ambient desorption/ionization mass spectrometry using a liquid sampling-atmospheric glow discharge (LS-APGD) ionization source

被引:35
|
作者
Marcus, R. Kenneth [1 ]
Burdette, Carolyn Q. [1 ]
Manard, Benjamin T. [1 ]
Zhang, Lynn X. [1 ]
机构
[1] Clemson Univ, Dept Chem, Clemson, SC 29634 USA
关键词
Liquid sampling-atmospheric pressure glow discharge; Microplasma; Ambient desorption/ionization; Mass spectrometry; OPTICAL-EMISSION SOURCE; REAL-TIME; CIGARETTE-SMOKE; ION-SOURCE; PLASMA; CATECHINS; DRUGS; EXTRACTS;
D O I
10.1007/s00216-013-7216-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel approach to ambient desorption/ionization mass spectrometry (ADI-MS) is described, based on a recently developed liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source. The device is essentially unmodified relative to its implementation in elemental mass spectrometry, where the operational space is characterized by low operation power (< 10 W) and low solution delivery rates (< 50 mu L min(-1)). In this implementation, the plasma is produced between a Ni anode and an electrolytic liquid (1 M HNO3) cathode flowing through a glass capillary that is angled towards the sample surface, at a distance of similar to 2 mm away. Analyte species can be desorbed/ionized from neat solution residues and complex solid samples. The ADI-LS-APGD source is mounted onto the source interface of a Thermo Finnigan LCQ Advantage Max quadrupole ion trap mass spectrometer without modifications to the instrument faceplate or ion optics. Described here is the initial evaluation of the roles of source geometry and working parameters, including electrolytic solution composition and plasma current, on the response of caffeine residues, with preliminary limits of detection based on the relative standard deviation of the spectral background suggested to be on the 10-pg level. Demonstrative spectra are presented for green tea extracts and raw leaves, coffee beans, a dried (raw) tobacco leaf, an analgesic tablet, and paper currency. Versatility is further revealed through the determination of components in common cigarette smoke. In each case, the spectra are characterized by (M + H)(+) species of the expected constituents. The capacity for a single source to perform both in solution and particulate elemental analysis (as shown previously) and ADI of molecular species is unique in the realm of mass spectrometry.
引用
收藏
页码:8171 / 8184
页数:14
相关论文
共 50 条
  • [31] Design and Application of Atmospheric Sampling Glow Discharge Ionization Mass Spectrometer
    Jiang You
    Dai Xin-Hua
    Huang Ze-Jian
    Xiong Xing-Chuang
    Fang Xiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (04) : 651 - 654
  • [32] Electrospray-atmospheric sampling glow discharge ionization source for the direct analysis of liquid samples
    Dalton, CN
    Glish, GL
    ANALYTICAL CHEMISTRY, 2003, 75 (07) : 1620 - 1627
  • [33] Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source
    Xie, Xiaobo
    Wang, Zhenpeng
    Li, Yafeng
    Zhan, Lingpeng
    Nie, Zongxiu
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (06) : 1036 - 1047
  • [34] Micro Plasma Generation Using Liquid Sampling-Atmospheric Pressure Glow Discharge
    Abdallah Shaltout
    Microchimica Acta, 2006, 155 : 447 - 452
  • [35] Mass spectrometry sampling under ambient conditions with desorption electrospray ionization
    Takáts, Z
    Wiseman, JM
    Gologan, B
    Cooks, RG
    SCIENCE, 2004, 306 (5695) : 471 - 473
  • [36] Investigation of spectrochemical matrix effects in the liquid sampling-atmospheric pressure glow discharge source
    Manard, Benjamin T.
    Gonzalez, Jhanis J.
    Sarkar, Arnab
    Mao, Xianglei
    Zhang, Lynn X.
    Konegger-Kappel, Stefanie
    Marcus, R. Kenneth
    Russo, Richard E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 100 : 44 - 51
  • [37] Investigation of hydrophobic substrates for solution residue analysis utilizing an ambient desorption liquid sampling-atmospheric pressure glow discharge microplasma
    Paing, Htoo W.
    Marcus, R. Kenneth
    ANALYST, 2018, 143 (06) : 1417 - 1425
  • [38] Micro plasma generation using liquid sampling-atmospheric pressure glow discharge
    Shaltout, Abdallah
    MICROCHIMICA ACTA, 2006, 155 (3-4) : 447 - 452
  • [39] Desorption electrospray ionization ambient mass spectrometry
    Beatriz Pomilio, Alicia
    Alberto Bernatene, Eduardo
    Alberto Vitale, Arturo
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2011, 45 (01): : 47 - 79
  • [40] ATMOSPHERIC SAMPLING GLOW-DISCHARGE IONIZATION SOURCE FOR THE DETERMINATION OF TRACE ORGANIC-COMPOUNDS IN AMBIENT AIR
    MCLUCKEY, SA
    GLISH, GL
    ASANO, KG
    GRANT, BC
    ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2220 - 2227