Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source for Elemental Mass Spectrometry

被引:75
|
作者
Marcus, R. Kenneth [1 ]
Quarles, C. Derrick, Jr. [1 ]
Barinaga, Charles J. [2 ]
Carado, Anthony J. [2 ]
Koppenaal, David W. [2 ]
机构
[1] Clemson Univ, Dept Chem, Clemson, SC 29634 USA
[2] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
OPTICAL-EMISSION SOURCE; ION-SOURCE; ELECTROLYTE; MEDIA;
D O I
10.1021/ac200098h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, low power ionization source for elemental MS analysis of aqueous solutions is described. The liquid sampling-atmospheric pressure grow discharge (LS-APGD) operates by a process wherein the surface of the liquid emanating from a 75 mu m i.d. glass capillary acts as the cathode of the direct current glow discharge. Analyte-containing solutions at a flow rate of 100 mu L min(-1) are vaporized by the passage of current, yielding gas phase solutes that are subsequently ionized in the <5 W (maximum of 60 mA and 500 V), similar to 1 mm(3) volume, plasma. The LS-APGD is mounted in place of the normal electrospray ionization source of a Thermo Scientific Exactive Orbitrap mass spectrometer system without any other modifications. Basic operating characteristics are described, including the role of discharge power on mass spectral composition, the ability to obtain ultrahigh resolution elemental isotopic patterns, and demonstration of potential limits of detection based on the injection of aliquots of multielement standards (S/N > 1000 for 5 ng mL(-1) Cs). While much optimization remains, it is believed that the LS-APGD ion source may present a practical alternative to high-powered (>1 kW) plasma sources typically employed in elemental mass spectrometry, particularly for those cases where costs, operational overhead, simplicity, or integrated elemental/molecular analysis considerations are important.
引用
收藏
页码:2425 / 2429
页数:5
相关论文
共 50 条
  • [1] Evaluation of the operating parameters of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry
    Zhang, Lynn X.
    Manard, Benjamin T.
    Kappel, Stefanie Konegger
    Marcus, R. Kenneth
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (29) : 7497 - 7509
  • [2] Evaluation of the operating parameters of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry
    Lynn X. Zhang
    Benjamin T. Manard
    Stefanie Konegger Kappel
    R. Kenneth Marcus
    Analytical and Bioanalytical Chemistry, 2014, 406 : 7497 - 7509
  • [3] Characterization of arsenic species by liquid sampling-atmospheric pressure glow discharge ionization mass spectrometry
    Goodwin, Joseph
    Marcus, R. Kenneth
    McRae, Garnet
    Sturgeon, Ralph E.
    Mester, Zoltan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (15) : 3585 - 3594
  • [4] Erratum to: Evaluation of the operating parameters of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry
    Lynn X. Zhang
    Benjamin T. Manard
    Stefanie Konegger-Kappel
    R. Kenneth Marcus
    Analytical and Bioanalytical Chemistry, 2014, 406 : 7741 - 7741
  • [5] Liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry: preliminary parametric evaluation and figures of merit
    Quarles, C. Derrick, Jr.
    Carado, Anthony J.
    Barinaga, Charles J.
    Koppenaal, David W.
    Marcus, R. Kenneth
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) : 261 - 268
  • [6] Ambient desorption/ionization mass spectrometry using a liquid sampling-atmospheric glow discharge (LS-APGD) ionization source
    Marcus, R. Kenneth
    Burdette, Carolyn Q.
    Manard, Benjamin T.
    Zhang, Lynn X.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (25) : 8171 - 8184
  • [7] Evaluation of the operating parameters of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry (vol 406, pg 7497, 2014)
    Zhang, Lynn X.
    Manard, Benjamin T.
    Konegger-Kappel, Stefanie
    Marcus, R. Kenneth
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (29) : 7741 - 7741
  • [8] Femtosecond laser ablation particle introduction to a liquid sampling-atmospheric pressure glow discharge ionization source
    Carado, Anthony J.
    Quarles, C. Derrick, Jr.
    Duffin, Andrew M.
    Barinaga, Charles J.
    Russo, Richard E.
    Marcus, R. Kenneth
    Eiden, Gregory C.
    Koppenaal, David W.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (03) : 385 - 389
  • [9] Investigation of spectrochemical matrix effects in the liquid sampling-atmospheric pressure glow discharge source
    Manard, Benjamin T.
    Gonzalez, Jhanis J.
    Sarkar, Arnab
    Mao, Xianglei
    Zhang, Lynn X.
    Konegger-Kappel, Stefanie
    Marcus, R. Kenneth
    Russo, Richard E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 100 : 44 - 51
  • [10] Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium
    Goodwin, Joseph V.
    Manard, Benjamin T.
    Ticknor, Brian W.
    Cable-Dunlap, Paula
    Marcus, R. Kenneth
    ANALYTICAL CHEMISTRY, 2023, 95 (32) : 12131 - 12138