Management of patients with implantable cardioverter-defibrillators and pacemakers who require radiation therapy

被引:41
|
作者
Brambatti, Michela [1 ,2 ]
Mathew, Rebecca [3 ]
Strang, Barbara [4 ]
Dean, Joan
Goyal, Anuja [1 ]
Hayward, Joseph E. [4 ]
Long, Laurene
DeMeis, Patty [4 ]
Smoke, Marcia [4 ]
Connolly, Stuart J. [1 ]
Morillo, Carlos A. [1 ]
Amit, Guy [1 ]
Capucci, Alessandro
Healey, Jeff S. [1 ]
机构
[1] McMaster Univ, Populat Hlth Res Inst, Hamilton, ON, Canada
[2] Univ Politecn Marche, Clin Cardiol & Aritmol, I-60100 Ancona, Italy
[3] McMaster Univ, Dept Internal Med, Hamilton, ON, Canada
[4] Hamilton Hlth Sci, Ctr Canc, Hamilton, ON, Canada
关键词
Pacemaker; Implantable cardioverter-defibrillator; Radiation therapy; Malfunction; Care path; CARDIAC-PACEMAKERS; LATEST GENERATION; ONCOLOGY PATIENTS; RADIOTHERAPY; IRRADIATION; DEVICE; SOCIETY; PROJECT;
D O I
10.1016/j.hrthm.2015.06.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Radiation therapy (RT) may pose acute and long-term risks for patients with cardiac implantable electronic devices (CIEDs), including pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). However, the frequency of these problems has not been accurately defined. OBJECTIVE The purpose of this study was to determine the prevalence of CIEDs among patients requiring RT and report the common CIED-related problems when patients are managed according to a standard clinical care path. METHODS In a single tertiary-care center, we prospectively screened all patients requiring RT and identified patients with ICDs or PMs. We collected clinical data about their cancer, RT treatment plan, and CIED. Radiation dose to the device was estimated in all patients, and any device malfunction during RT was documented. RESULTS Of the 34,706 consecutive patients receiving RT, 261 patients (0.8%, mean age 77.9 +/- 9.4 years) had an implantable cardiac device: 54 (20.7%) ICDs and 207 (79.3%) PMs. The site of RT was head and neck (27.4%), chest (30.0%), and abdomen/pelvis (32.6%). Using our care path, 63.2% of patients required continuous cardiac monitoring, 14.6% required device reprogramming, 18.8% required magnet application during RT, and 3.4%, required device repositioning to the contralateral side before RT. Four patients (1.5%) had inappropriate device function during RT: 3 experienced hemodynamically tolerated ventricular pacing at the maximum sensor rate, and 1 experienced a device power-on-reset. No patient died or suffered permanent device failure. CONCLUSION Nearly 1% of patients receiving RT in this series has a PM or ICD. However, with a systematic policy of risk assessment and patient management, significant device-related complications are rare.
引用
下载
收藏
页码:2148 / 2154
页数:7
相关论文
共 50 条
  • [31] Who should be treated with implantable cardioverter-defibrillators?
    Weber, Michael A.
    Wenger, Nanette K.
    Scheidt, Stephen
    AMERICAN JOURNAL OF GERIATRIC CARDIOLOGY, 2006, 15 (06): : 336 - 337
  • [32] Experiences of magnetic resonance imaging scanning in patients with pacemakers or implantable cardioverter-defibrillators
    Han, Donghoon
    Kang, Si-Hyuck
    Cho, Youngjin
    Oh, Il-Young
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2019, 34 (01): : 99 - +
  • [33] Why Are Implantable Cardioverter-Defibrillators and Pacemakers Being Revised Today?
    Hanzlik, J. A.
    Patel, J. D.
    Kurtz, S. M.
    Horn, Q. C.
    Shkolnikov, Y. P.
    Ochoa, J. A.
    Pavri, B. B.
    Greenspon, A. J.
    MEDICAL DEVICE MATERIALS VI, 2013, : 57 - 62
  • [34] Safety Profile of Liver FibroScan in Patients with Cardiac Pacemakers or Implantable Cardioverter-Defibrillators
    Chan, Yin
    Pranke, Stephanie
    Rashidi, Farid
    Nosib, Shravan
    Worobetz, Lawrence
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 2017
  • [35] Magnetic resonance imaging in patients with pacemakers and implantable cardioverter-defibrillators: A systematic review
    Martins, R. -P.
    Baruteau, A. -E.
    Treguer, F.
    Cesari, O.
    Carsin-Nicol, B.
    Langella, B.
    Leclercq, C.
    Daubert, J. -C.
    Mabo, P.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2010, 59 (04): : 221 - 228
  • [36] IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    KUTALEK, SP
    DREIFUS, LS
    ADVANCES IN INTERNAL MEDICINE, VOLUME 38, 1993, 38 : 421 - 438
  • [37] Implantable cardioverter-defibrillators
    DiMarco, JP
    NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (19): : 1836 - 1847
  • [38] MASK MAGNETS MAY INTERACT WITH PACEMAKERS AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    Ruoff, Chad
    Tashman, Yasemin
    Miller, Bernie
    Houser, Ryan
    Cheema, Kamal
    Haley, Caitlin
    Petersen, Ann
    Lizak, Matthew
    Goswami, Umesh
    Lizak, Trevor
    Krahn, Lois
    Srivathsan, Komandoor
    SLEEP, 2022, 45 : A342 - A343
  • [39] Implantable Cardioverter-Defibrillators in Patients With COPD
    Naksuk, Niyada
    Kunisaki, Ken M.
    Benditt, David G.
    Tholakanahalli, Venkatakrishna
    Adabag, Selcuk
    CHEST, 2013, 144 (03) : 778 - 783
  • [40] Implantable cardioverter-defibrillators in dialysis patients
    Mills, Mark T.
    BMJ EVIDENCE-BASED MEDICINE, 2020, 25 (05) : 187 - 188