Management of patients with implantable cardioverter-defibrillators and pacemakers who require radiation therapy

被引:41
|
作者
Brambatti, Michela [1 ,2 ]
Mathew, Rebecca [3 ]
Strang, Barbara [4 ]
Dean, Joan
Goyal, Anuja [1 ]
Hayward, Joseph E. [4 ]
Long, Laurene
DeMeis, Patty [4 ]
Smoke, Marcia [4 ]
Connolly, Stuart J. [1 ]
Morillo, Carlos A. [1 ]
Amit, Guy [1 ]
Capucci, Alessandro
Healey, Jeff S. [1 ]
机构
[1] McMaster Univ, Populat Hlth Res Inst, Hamilton, ON, Canada
[2] Univ Politecn Marche, Clin Cardiol & Aritmol, I-60100 Ancona, Italy
[3] McMaster Univ, Dept Internal Med, Hamilton, ON, Canada
[4] Hamilton Hlth Sci, Ctr Canc, Hamilton, ON, Canada
关键词
Pacemaker; Implantable cardioverter-defibrillator; Radiation therapy; Malfunction; Care path; CARDIAC-PACEMAKERS; LATEST GENERATION; ONCOLOGY PATIENTS; RADIOTHERAPY; IRRADIATION; DEVICE; SOCIETY; PROJECT;
D O I
10.1016/j.hrthm.2015.06.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Radiation therapy (RT) may pose acute and long-term risks for patients with cardiac implantable electronic devices (CIEDs), including pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). However, the frequency of these problems has not been accurately defined. OBJECTIVE The purpose of this study was to determine the prevalence of CIEDs among patients requiring RT and report the common CIED-related problems when patients are managed according to a standard clinical care path. METHODS In a single tertiary-care center, we prospectively screened all patients requiring RT and identified patients with ICDs or PMs. We collected clinical data about their cancer, RT treatment plan, and CIED. Radiation dose to the device was estimated in all patients, and any device malfunction during RT was documented. RESULTS Of the 34,706 consecutive patients receiving RT, 261 patients (0.8%, mean age 77.9 +/- 9.4 years) had an implantable cardiac device: 54 (20.7%) ICDs and 207 (79.3%) PMs. The site of RT was head and neck (27.4%), chest (30.0%), and abdomen/pelvis (32.6%). Using our care path, 63.2% of patients required continuous cardiac monitoring, 14.6% required device reprogramming, 18.8% required magnet application during RT, and 3.4%, required device repositioning to the contralateral side before RT. Four patients (1.5%) had inappropriate device function during RT: 3 experienced hemodynamically tolerated ventricular pacing at the maximum sensor rate, and 1 experienced a device power-on-reset. No patient died or suffered permanent device failure. CONCLUSION Nearly 1% of patients receiving RT in this series has a PM or ICD. However, with a systematic policy of risk assessment and patient management, significant device-related complications are rare.
引用
下载
收藏
页码:2148 / 2154
页数:7
相关论文
共 50 条
  • [21] Treatment of patients with cardiac pacemakers and implantable cardioverter-defibrillators during radiotherapy
    Solan, AN
    Solan, MJ
    Bednarz, G
    Goodkin, MB
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03): : 897 - 904
  • [22] Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators
    Chamis, AL
    Peterson, GE
    Cabell, CH
    Corey, GR
    Sorrentino, RA
    Greenfield, RA
    Ryan, T
    Reller, LB
    Fowler, VG
    CIRCULATION, 2001, 104 (09) : 1029 - 1033
  • [23] A comparison of psychosocial adaptation and acceptance in patients with pacemakers and implantable cardioverter-defibrillators
    Büchi, S
    Klaghofer, R
    Duru, F
    Candinas, R
    Buddeberg, C
    JOURNAL OF PSYCHOSOMATIC RESEARCH, 2000, 48 (03) : 282 - 282
  • [24] TREATMENT OF VENTRICULAR TACHYARRHYTHMIAS IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS AND ANTITACHYCARDIA PACEMAKERS
    WINTERS, SL
    CAMUNAS, J
    ERGIN, A
    ESTIOKO, M
    GOMES, JA
    CURRENT OPINION IN CARDIOLOGY, 1989, 4 (04) : 555 - 558
  • [25] Perioperative management of patients with pacemakers and implantable cardioverter defibrillators
    Rasche, S.
    Hardt, F.
    Braun, M.
    Koch, T.
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 2006, 47 : 658 - +
  • [26] Assessment and management of patients with pacemakers and implantable cardioverter defibrillators
    Stone, KR
    McPherson, CA
    CRITICAL CARE MEDICINE, 2004, 32 (04) : S155 - S165
  • [27] Patients with hemodynamically tolerated ventricular tachycardia require implantable cardioverter-defibrillators
    Callans, David J.
    CIRCULATION, 2007, 116 (10) : 1196 - 1203
  • [28] Management of spinal cord stimulators in patients with refractory angina pectoris and implantable pacemakers and cardioverter-defibrillators
    Eckert, S.
    Buschler, H.
    Lamp, B.
    Dongas, A.
    Gueldner, H.
    Horstkotte, D.
    EUROPEAN HEART JOURNAL, 2006, 27 : 463 - 463
  • [29] Comparative Analysis of Response to Cardiac Resynchronisation Therapy Upgrades in Patients with Implantable Cardioverter-Defibrillators and Pacemakers
    Farhangee, Arsalan
    Davies, Mark J.
    Mesina, Mihai
    Morgan, David Roger
    Sieniewicz, Benjamin J.
    Meyrick, Robyn
    Gaughan, Katie
    Mindrila, Ion
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (10)
  • [30] Impact of cardiac resynchronisation therapy on cardiologists' exposure to radiation during implantation of pacemakers and implantable cardioverter-defibrillators
    Daval, Charline
    Faroux, Laurent
    Lesaffre, Francois
    Blanpain, Thierry
    Chabert, Jean-Pierre
    Martin, Angeline
    Guinot, Mathias
    Luconi, Nicolas
    Espinosa, Madeline
    Nazeyrollas, Pierre
    Tourneux, Christophe
    Metz, Damien
    JOURNAL OF RADIOLOGICAL PROTECTION, 2019, 39 (02) : 489 - 497