Safety Profile of Liver FibroScan in Patients with Cardiac Pacemakers or Implantable Cardioverter-Defibrillators

被引:2
|
作者
Chan, Yin [1 ]
Pranke, Stephanie [1 ]
Rashidi, Farid [2 ]
Nosib, Shravan [3 ]
Worobetz, Lawrence [1 ]
机构
[1] Univ Saskatchewan, Dept Med, Div Gastroenterol, Saskatoon, SK, Canada
[2] Univ Saskatchewan, Dept Med Imaging, Saskatoon, SK, Canada
[3] Univ Saskatchewan, Dept Med, Div Cardiol, Saskatoon, SK, Canada
关键词
TRANSIENT ELASTOGRAPHY; STIFFNESS; CIRRHOSIS; RELIABILITY;
D O I
10.1155/2017/7298032
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background. Emerging evidence suggests that nonalcoholic fatty liver disease (NAFLD) is associated with coronary artery diseases and arrhythmias. The FibroScan (Echosens, France), a widely available, noninvasive device, is able to detect liver fibrosis and steatosis within this patient population. However, the FibroScan is currently contraindicated in patients with cardiac pacemakers (PM) or implantable cardioverter- defibrillators (ICD). Objective. To determine the safety profile of FibroScan testing in patients with PM or ICD. Methods. Consecutive outpatients undergoing routine device interrogations at a tertiary level teaching hospital underwent simultaneous liver stiffness measurements. PMor ICD performance data, device types, patient demographics, medical history, and previous laboratory and conventional liver imaging results were collected. Results. Analysis of 107 subjects with 33 different types of implanted cardiac devices, from 5 different companies (Medtronic, Sorin, ELA Medical, Boston Scientific, and St. Jude), did not demonstrate any adverse events as defined by abnormal device sensing/pacing or ICD firing. This population included high risk subjects undergoing active pacing (n = 53) and with right pectoral PM placement (n = 1). None of the subjects had any clinical signs of decompensated congestive heart failure or cirrhosis during the exam. Conclusion. TE with FibroScan can be safely performed in patients with PMor ICD.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Safety Profile of Liver FibroScan® in Patients With Cardiac Pacemakers or Implantable Cardioverter-Defibrillators
    Chan, Yin
    Pranke, Stephanie
    Wang, Samuel
    Nosib, Shravan
    Worobetz, Lawrence
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2015, 110 : S892 - S892
  • [2] Safety of Electromagnetic Articulography in Patients With Pacemakers and Implantable Cardioverter-Defibrillators
    Joglar, Jose A.
    Nguyen, Carol
    Garst, Diane M.
    Katz, William F.
    [J]. JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2009, 52 (04): : 1082 - 1087
  • [3] Pacemakers and implantable cardioverter-defibrillators in pediatric patients
    Silka, Michael J.
    Bar-Cohen, Yaniv
    [J]. HEART RHYTHM, 2006, 3 (11) : 1360 - 1366
  • [4] Leadless Cardiac Devices—Pacemakers and Implantable Cardioverter-Defibrillators
    Rutzen-Lopez H.
    Silva J.
    Helm R.H.
    [J]. Current Treatment Options in Cardiovascular Medicine, 2016, 18 (8)
  • [5] Treatment of patients with cardiac pacemakers and implantable cardioverter-defibrillators during radiotherapy
    Solan, AN
    Solan, MJ
    Bednarz, G
    Goodkin, MB
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03): : 897 - 904
  • [6] Troubleshooting pacemakers and implantable cardioverter-defibrillators
    Scher, DL
    [J]. CURRENT OPINION IN CARDIOLOGY, 2004, 19 (01) : 36 - 46
  • [7] Deactivation of Pacemakers and Implantable Cardioverter-Defibrillators
    Kramer, Daniel B.
    Mitchell, Susan L.
    Brock, Dan W.
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 2012, 55 (03) : 290 - 299
  • [8] Perioperative management of patients with pacemakers and implantable cardioverter-defibrillators
    Hollenbach, E.
    [J]. ANAESTHESIST, 2009, 58 (05): : 451 - 452
  • [9] Dermatologic electrosurgery in patients with implantable cardioverter-defibrillators and pacemakers
    LeVasseur, MJG
    Kennard, CD
    Finley, MEM
    Muse, MRK
    [J]. DERMATOLOGIC SURGERY, 1998, 24 (02) : 233 - 240
  • [10] Beam profile disturbances from interactions with implantable pacemakers and implantable cardioverter-defibrillators
    Gossman, Michael S.
    Blohm, Christopher M.
    [J]. MEDICAL DOSIMETRY, 2013, 38 (02) : 109 - 109