Defects in Nickel-Titanium Instruments after Clinical Use. Part 2: Fractographic Analysis of Fractured Surface in a Cohort Study

被引:53
|
作者
Shen, Ya [1 ]
Cheung, Gary Shun-pan [2 ]
Peng, Bin [3 ]
Haapasalo, Markus [1 ]
机构
[1] Univ British Columbia, Fac Dent, Div Endodont, Dept Oral Biol & Med Sci, Vancouver, BC V6T 1Z3, Canada
[2] Univ Hong Kong, Fac Dent, Area Endodont, Hong Kong, Hong Kong, Peoples R China
[3] Wuhan Univ, Sch & Hosp Stomatol, Minist Educ, Key Lab Oral Biomed Engn, Wuhan 430072, Peoples R China
关键词
Clinical; failure; fatigue; nickel-titanium; rotary instrument; shear; NITI ROTARY INSTRUMENTS; ROOT-CANAL PREPARATION; LOW-CYCLE FATIGUE; PROTAPER-S1; INSTRUMENTS; ENDODONTIC INSTRUMENTS; BENDING PROPERTIES; PROFILE; FAILURE; FILES; STRESSES;
D O I
10.1016/j.joen.2008.10.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to investigate the mode of failure of three brands of nickel-titanium (NiTi) instruments (ProTaper [Dentsply Maillefer, Ballaigues, Switzerland], ProTaper for Hand Use [Dentsply Maillefer], and K3 [SybronEndo, Orange, CA]) that separated during clinical use. A total of 79 fractured instruments were collected from three endodontic clinics over 16 months. The fracture surface of each fragment was examined by scanning electron microscope. Most of the rotary instruments (78% of K3 and 66% of ProTaper) failed because of fatigue fracture, whereas 91% of NiTi hand instruments failed as a result of shear (p < 0.01). The fracture mode of shaping files in rotary ProTaper was different between two different clinics (p < 0.05). All surfaces with fatigue fracture (n = 47) revealed the presence of either one or two crack origins. The vast majority (86%) of K3 fatigue failure had two crack origins that could be found not only at the cutting edge but also at various places along the flute compared with only 28% of ProTaper showing multiple crack origins (p < 0.01). The latter showed one crack origin in 81% of the fatigued shaping files but only 37% for finishing files (p < 0.01). The results of this study indicated that the failure mode of NiTi instruments is related to preparation technique. (J Endod 2009;35:133-136)
引用
收藏
页码:133 / 136
页数:4
相关论文
共 50 条
  • [41] Shaping ability of ProFile rotary nickel-titanium instruments with ISO sized tips in simulated root canals: Part 2
    Bryant, ST
    Thompson, SA
    Al-Omari, MAO
    Dummer, PMH
    INTERNATIONAL ENDODONTIC JOURNAL, 1998, 31 (04) : 282 - 289
  • [42] The influence of simulated clinical use on the flexibility of rotary ProTaper Universal, K3 and EndoSequence nickel-titanium instruments
    Viana, A. C. D.
    Pereira, E. S. J.
    Bahia, M. G. A.
    Buono, V. T. L.
    INTERNATIONAL ENDODONTIC JOURNAL, 2013, 46 (09) : 855 - 862
  • [43] Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use (vol 104, pg 77, 2016)
    Gambarini, Gianluca
    Rubini, Alessio Giansiracusa
    Sannino, Giampaolo
    Di Giorgio, Gianni
    Piasecki, Lucila
    Al-Sudani, Dina
    Plotino, Gianluca
    Testarelli, Luca
    ODONTOLOGY, 2016, 104 (01) : 82 - 82
  • [44] Extrusion of debris after use of rotary nickel-titanium files with different pitch: A pilot study
    Elmsallati, Elham A.
    Wadachi, Reiko
    Suda, Hideaka
    AUSTRALIAN ENDODONTIC JOURNAL, 2009, 35 (02) : 65 - 69
  • [45] Effect of repetitive up-and-down movements on torque/force generation, surface defects and shaping ability of nickel-titanium rotary instruments: an ex vivo study
    Kyaw, Moe Sandar
    Ebihara, Arata
    Iino, Yoshiko
    Thu, Myint
    Maki, Keiichiro
    Kimura, Shunsuke
    Htun, Pyae Hein
    Okiji, Takashi
    BMC ORAL HEALTH, 2024, 24 (01):
  • [46] Comparison of postoperative pain after the use of different nickel-titanium instrumentation systems: A randomized clinical trial
    Yilmaz, Ozlem S.
    Keskin, Cangul
    Acar, Duygu H.
    Aydemir, Hikmet
    EUROPEAN ORAL RESEARCH, 2022, 56 (02) : 102 - 109
  • [47] Scanning electron microscopy of superficial defects in Twisted files and Reciproc nickel-titanium files after use in extracted molars
    Caballero, H.
    Rivera, F.
    Salas, H.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (03) : 229 - 235
  • [48] Microscopic Analysis of Fractured Dental Implant Surface after Clinical Use
    Kim, R. W.
    Kim, H. S.
    Choe, H. C.
    Son, M. K.
    Chung, C. H.
    11TH INTERNATIONAL CONFERENCE ON THE MECHANICAL BEHAVIOR OF MATERIALS (ICM11), 2011, 10 : 1955 - 1960
  • [49] Analysis of defects in ProTaper hand-operated instruments after clinical use
    Shen, Ya
    Bian, Zhuan
    Cheung, Gary Shun-pan
    Peng, Bin
    JOURNAL OF ENDODONTICS, 2007, 33 (03) : 287 - 290
  • [50] Surface deformation of several nickel-titanium rotary instruments after removal of the root canal filling materials: a scanning electron microscope evaluation
    Ozyurek, Taha
    Demiryurek, Ebru Ozsezer
    ODONTOLOGY, 2020, 108 (02) : 213 - 221