Defects in Nickel-Titanium Instruments after Clinical Use. Part 2: Fractographic Analysis of Fractured Surface in a Cohort Study

被引:53
|
作者
Shen, Ya [1 ]
Cheung, Gary Shun-pan [2 ]
Peng, Bin [3 ]
Haapasalo, Markus [1 ]
机构
[1] Univ British Columbia, Fac Dent, Div Endodont, Dept Oral Biol & Med Sci, Vancouver, BC V6T 1Z3, Canada
[2] Univ Hong Kong, Fac Dent, Area Endodont, Hong Kong, Hong Kong, Peoples R China
[3] Wuhan Univ, Sch & Hosp Stomatol, Minist Educ, Key Lab Oral Biomed Engn, Wuhan 430072, Peoples R China
关键词
Clinical; failure; fatigue; nickel-titanium; rotary instrument; shear; NITI ROTARY INSTRUMENTS; ROOT-CANAL PREPARATION; LOW-CYCLE FATIGUE; PROTAPER-S1; INSTRUMENTS; ENDODONTIC INSTRUMENTS; BENDING PROPERTIES; PROFILE; FAILURE; FILES; STRESSES;
D O I
10.1016/j.joen.2008.10.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to investigate the mode of failure of three brands of nickel-titanium (NiTi) instruments (ProTaper [Dentsply Maillefer, Ballaigues, Switzerland], ProTaper for Hand Use [Dentsply Maillefer], and K3 [SybronEndo, Orange, CA]) that separated during clinical use. A total of 79 fractured instruments were collected from three endodontic clinics over 16 months. The fracture surface of each fragment was examined by scanning electron microscope. Most of the rotary instruments (78% of K3 and 66% of ProTaper) failed because of fatigue fracture, whereas 91% of NiTi hand instruments failed as a result of shear (p < 0.01). The fracture mode of shaping files in rotary ProTaper was different between two different clinics (p < 0.05). All surfaces with fatigue fracture (n = 47) revealed the presence of either one or two crack origins. The vast majority (86%) of K3 fatigue failure had two crack origins that could be found not only at the cutting edge but also at various places along the flute compared with only 28% of ProTaper showing multiple crack origins (p < 0.01). The latter showed one crack origin in 81% of the fatigued shaping files but only 37% for finishing files (p < 0.01). The results of this study indicated that the failure mode of NiTi instruments is related to preparation technique. (J Endod 2009;35:133-136)
引用
收藏
页码:133 / 136
页数:4
相关论文
共 50 条
  • [31] Evaluating Two Techniques on Removal of Fractured Rotary Nickel-Titanium Endodontic Instruments from Root Canals: An In Vitro Study
    Alomairy, Khalid H.
    JOURNAL OF ENDODONTICS, 2009, 35 (04) : 559 - 562
  • [32] Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: An experimental study
    Ward, JR
    Parashos, P
    Messer, HH
    JOURNAL OF ENDODONTICS, 2003, 29 (11) : 756 - 763
  • [33] Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: Part 2
    Thompson, SA
    Dummer, PMH
    INTERNATIONAL ENDODONTIC JOURNAL, 2000, 33 (03) : 255 - 261
  • [34] Undergraduate teaching and clinical use of rotary nickel-titanium endodontic instruments: A survey of French dental schools
    Arbab-Chirani, R
    Vulcain, JM
    INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (05) : 320 - 324
  • [35] Thickness of remaining dentin in mesial roots of mandibular molars after the use of nickel-titanium instruments.
    Binda, A
    Andrighetto, AG
    Neuvald, L
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A321 - A321
  • [36] Characterisation of deformed or separated nickel-titanium retreatment instruments after clinical use-A multicentre experience Defect profiles of clinically-used retreatment instruments
    Liu, He
    Shabehpour, Kiarash
    Wang, Zhejun
    Sobotkiewicz, Tyler
    Kwak, Sang Won
    Haapasalo, Markus
    Ruse, N. Dorin
    Coil, Jeffrey M.
    Tay, Franklin R.
    Shen, Ya
    JOURNAL OF DENTISTRY, 2022, 117
  • [37] Chemical Analysis of Nickel-Titanium Rotary Instruments with and without Electropolishing after Cleaning Procedures with Sodium Hypochlorite
    Bonaccorso, Antonio
    Schaefer, Edgar
    Condorelli, Guglielmo Guido
    Cantatore, Giuseppe
    Tripi, Teresa Roberta
    JOURNAL OF ENDODONTICS, 2008, 34 (11) : 1391 - 1395
  • [38] Ultrastructural analysis of the root canal walls after preparation with two rotary nickel-titanium endodontic instruments
    Poggio, Claudio
    Dagna, Alberto
    Chiesa, Marco
    Beltrami, Riccardo
    Colombo, Marco
    CONTEMPORARY CLINICAL DENTISTRY, 2014, 5 (03) : 357 - 360
  • [39] The use of rotary nickel-titanium endodontic instruments by Dental practitioner in Saudi Arabia - A cross sectional study
    Altammami, Musaed F.
    Al-oraini, Abdullah A.
    Alotaibi, Abdulelah N.
    Alkhashman, Abdulla A.
    Alshalawi, Maha M.
    Almuhraj, Nouf A.
    Almofada, Sarah K.
    Aloraini, Asim A.
    MEDICAL SCIENCE, 2020, 24 (105) : 3017 - 3023
  • [40] Cyclic fatigue resistance and shaping ability of heat-treated nickel-titanium instruments after repeated use
    Kamali, S. G.
    Turkaydin, D.