Automated recognition of ergogenic aids using Soft Independent Modeling of Class Analogy (SIMCA)

被引:0
|
作者
Praisler, M
Van Bocxlaer, J
De Leenheer, A
Massart, DL
机构
[1] Univ Galati, Dept Phys, Galati 6200, Romania
[2] State Univ Ghent, Lab Med Biochem & Clin Anal, B-9000 Ghent, Belgium
[3] Free Univ Brussels, Lab Pharmaceut & Biomed Anal, B-1090 Brussels, Belgium
来源
TURKISH JOURNAL OF CHEMISTRY | 2002年 / 26卷 / 01期
关键词
principal component analysis; Soft Independent Modeling of Class Analogy; infrared spectrum; amphetamines; drugs of abuse;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The introduction of effective drug testing procedures in doping control reduced, but did not eliminate, their abuse by athletes. The most important analytical challenge is the recognition of the new analog compounds. In attempts to circumvent existing controlled substance laws, slightly modified chemical structures (by adding or changing substituents at various positions on the banned molecules) are used. As a result, no substance belonging to a prohibited class may be used nowadays, even if it has not been specifically listed. We present a chemometric procedure acting as an automated GC-FTIR screening test detecting the molecular structural similarity of unknown compounds with the main classes of ergogenic aids. The knowledge base defining the reference GC-FTIR spectral patterns has been built according to criteria encompassing toxicological, pharmacological and neurochemical aspects. The class identity of a compound is diagnosed within seconds, using Soft Independent Modeling of Class Analog (SIMCA). The predictive value of the system was assessed at a testing accuracy of 95%. Compounds giving cross-reactions with traditional screening techniques produce a negative result. The specificity and the selectivity of the screening test, evaluated by testing 160 toxicologically relevant compounds, are discussed, emphasizing the chemical and physical factors affecting these parameters. The specificity of the system recommends the procedure as a highly specific, selective, fast, and user-friendly screening test, which screens for ergogenic aids found in powders, tablets or solutions with a prediction accuracy adequate for investigations in analytical toxicology and doping control.
引用
收藏
页码:45 / 58
页数:14
相关论文
共 50 条
  • [41] Diagnosis of basal cell carcinoma by infrared spectroscopy of whole blood samples applying soft independent modeling class analogy
    Mohammadreza Khanmohammadi
    Razieh Nasiri
    Keyvan Ghasemi
    Simin Samani
    Amir Bagheri Garmarudi
    Journal of Cancer Research and Clinical Oncology, 2007, 133 : 1023 - 1023
  • [42] Determination of Adulteration of the B10 Blend of Diesel and Crambe Biodiesel Using Proton Nuclear Magnetic Resonance (1H NMR) Spectroscopy with a Data Driven Soft Independent Modeling of Class Analogy (DD-SIMCA) Model
    Viagem Maquina, Ademar Domingos
    Sitoe, Baltazar Vasco
    de Santana, Felipe Bachion
    Santos, Douglas Queiroz
    Neto, Waldomiro Borges
    ANALYTICAL LETTERS, 2021, 54 (05) : 790 - 801
  • [43] Diagnosis of basal cell carcinoma by infrared spectroscopy of whole blood samples applying soft independent modeling class analogy
    Khanmohammadi, Mohammadreza
    Nasiri, Razieh
    Ghasemi, Keyvan
    Samani, Simin
    Garmarudi, Amir Bagheri
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2007, 133 (12) : 1001 - 1010
  • [44] Determination of Adulteration in Philippine Coconut Wine using Principal Component Analysis and Soft Independent Modelling of Class Analogy
    Baquiran, Velorie D.
    Bate, Jelani Anne M.
    Sembrano, Marene Joecel B.
    Flores Villaverde, Jocelyn
    Magwili, Glenn V.
    2019 4TH IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - ASIA (IEEE ICCE-ASIA 2019), 2019, : 25 - 29
  • [46] Shopping behavior recognition using a language modeling analogy
    Popa, M. C.
    Rothkrantz, L. J. M.
    Wiggers, P.
    Shan, C.
    PATTERN RECOGNITION LETTERS, 2013, 34 (15) : 1879 - 1889
  • [47] Decision criteria for soft independent modelling of class analogy applied to near infrared data
    De Maesschalck, R
    Candolfi, A
    Massart, DL
    Heuerding, S
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 47 (01) : 65 - 77
  • [48] Diagnosis of colon cancer by attenuated total reflectance-fourier transform infrared microspectroscopy and soft independent modeling of class analogy
    Mohammadreza Khanmohammadi
    Amir Bagheri Garmarudi
    Keyvan Ghasemi
    Hadigheh Kazemi Jaliseh
    Ahmad Kaviani
    Medical Oncology, 2009, 26 : 292 - 297
  • [49] Diagnosis of colon cancer by attenuated total reflectance-fourier transform infrared microspectroscopy and soft independent modeling of class analogy
    Khanmohammadi, Mohammadreza
    Garmarudi, Amir Bagheri
    Ghasemi, Keyvan
    Jaliseh, Hadigheh Kazemi
    Kaviani, Ahmad
    MEDICAL ONCOLOGY, 2009, 26 (03) : 292 - 297
  • [50] Comparing data driven soft independent class analogy (DD-SIMCA) and one class partial least square (OC-PLS) to authenticate sacha inchi (Plukenetia volubilis L.) oil using portable NIR spectrometer
    Cruz-Tirado, J. P.
    Munoz-Pastor, Daniela
    Moraes, Ingrid A. de
    Lima, Adriano Freitas
    Godoy, Helena Teixeira
    Barbin, Douglas Fernandes
    Siche, Raul
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2023, 242