Automated recognition of ergogenic aids using Soft Independent Modeling of Class Analogy (SIMCA)

被引:0
|
作者
Praisler, M
Van Bocxlaer, J
De Leenheer, A
Massart, DL
机构
[1] Univ Galati, Dept Phys, Galati 6200, Romania
[2] State Univ Ghent, Lab Med Biochem & Clin Anal, B-9000 Ghent, Belgium
[3] Free Univ Brussels, Lab Pharmaceut & Biomed Anal, B-1090 Brussels, Belgium
来源
TURKISH JOURNAL OF CHEMISTRY | 2002年 / 26卷 / 01期
关键词
principal component analysis; Soft Independent Modeling of Class Analogy; infrared spectrum; amphetamines; drugs of abuse;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The introduction of effective drug testing procedures in doping control reduced, but did not eliminate, their abuse by athletes. The most important analytical challenge is the recognition of the new analog compounds. In attempts to circumvent existing controlled substance laws, slightly modified chemical structures (by adding or changing substituents at various positions on the banned molecules) are used. As a result, no substance belonging to a prohibited class may be used nowadays, even if it has not been specifically listed. We present a chemometric procedure acting as an automated GC-FTIR screening test detecting the molecular structural similarity of unknown compounds with the main classes of ergogenic aids. The knowledge base defining the reference GC-FTIR spectral patterns has been built according to criteria encompassing toxicological, pharmacological and neurochemical aspects. The class identity of a compound is diagnosed within seconds, using Soft Independent Modeling of Class Analog (SIMCA). The predictive value of the system was assessed at a testing accuracy of 95%. Compounds giving cross-reactions with traditional screening techniques produce a negative result. The specificity and the selectivity of the screening test, evaluated by testing 160 toxicologically relevant compounds, are discussed, emphasizing the chemical and physical factors affecting these parameters. The specificity of the system recommends the procedure as a highly specific, selective, fast, and user-friendly screening test, which screens for ergogenic aids found in powders, tablets or solutions with a prediction accuracy adequate for investigations in analytical toxicology and doping control.
引用
收藏
页码:45 / 58
页数:14
相关论文
共 50 条
  • [21] Classification of waste materials using Fourier transform infrared spectroscopy and soft independent modeling of class analogy
    Smidt, E.
    Meissi, K.
    Schwanninger, M.
    Lechner, P.
    WASTE MANAGEMENT, 2008, 28 (10) : 1699 - 1710
  • [22] Class Modeling Analysis of Heparin 1H NMR Spectral Data Using the Soft Independent Modeling of Class Analogy and Unequal Class Modeling Techniques
    Zang, Qingda
    Keire, David A.
    Wood, Richard D.
    Buhse, Lucinda F.
    Moore, Christine M. V.
    Nasr, Moheb
    Al-Hakim, Ali
    Trehy, Michael L.
    Welsh, William J.
    ANALYTICAL CHEMISTRY, 2011, 83 (03) : 1030 - 1039
  • [23] Independent neural network modeling of class analogy for classification pattern recognition and optimization
    Liu, HL
    Cao, XW
    Xu, RJ
    Chen, NY
    ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) : 223 - 228
  • [24] ANALYSIS OF AIR-POLLUTION PLANT-EXPOSURE DATA - THE SOFT INDEPENDENT MODELING OF CLASS ANALOGY (SIMCA) AND PARTIAL LEAST-SQUARES MODELING WITH LATENT VARIABLE (PLS) APPROACHES
    MOSEHOLM, L
    ENVIRONMENTAL POLLUTION, 1988, 53 (1-4) : 313 - 331
  • [25] Composition of the bacterial population in sand-filter columns receiving artificial wastewater, evaluated by soft independent modelling of class analogy (SIMCA)
    Swedish Univ of Agricultural, Sciences, Uppsala, Sweden
    Water Res, 10 (2479-2487):
  • [26] Composition of the bacterial population in sand-filter columns receiving artificial wastewater, evaluated by soft independent modelling of class analogy (SIMCA)
    Pell, M
    Ljunggren, H
    WATER RESEARCH, 1996, 30 (10) : 2479 - 2487
  • [27] Determination of Trichinella spiralis in pig muscles using Mid-Fourier Transform Infrared Spectroscopy (MID-FTIR) with Attenuated Total Reflectance (ATR) and Soft Independent Modeling of Class Analogy (SIMCA)
    Gomez-De-Anda, Fabian
    Dorantes-Alvarez, Lidia
    Gallardo-Velazquez, Tzayhri
    Osorio-Revilla, Guillermo
    Calderon-Dominguez, Georgina
    Martinez Labat, Pablo
    de-la-Rosa-Arana, Jorge-Luis
    MEAT SCIENCE, 2012, 91 (03) : 240 - 246
  • [28] Classification of Geological Samples Based on Soft Independent Modeling of Class Analogy Using Laser-Induced Breakdown Spectroscopy
    Zhang, Ying
    Li, Ying
    Li, Wendong
    Sun, Zigang
    Bi, Yunfeng
    JOURNAL OF SPECTROSCOPY, 2018, 2018
  • [29] Is soft independent modeling of class analogies a reasonable choice for supervised pattern recognition?
    Racz, Anita
    Gere, Attila
    Bajusz, David
    Heberger, Karoly
    RSC ADVANCES, 2018, 8 (01) : 10 - 21
  • [30] Differentiation of Salmonella enterica Serovars and Strains in Cultures and Food Using Infrared Spectroscopic and Microspectroscopic Techniques Combined with Soft Independent Modeling of Class Analogy Pattern Recognition Analysis
    Mannig, Annegret
    Baldauf, Natan A.
    Rodriguez-Romo, Luis A.
    Yousef, Ahnied E.
    Rodriguez-Saona, Luis E.
    JOURNAL OF FOOD PROTECTION, 2008, 71 (11) : 2249 - 2256