Automated recognition of ergogenic aids using Soft Independent Modeling of Class Analogy (SIMCA)

被引:0
|
作者
Praisler, M
Van Bocxlaer, J
De Leenheer, A
Massart, DL
机构
[1] Univ Galati, Dept Phys, Galati 6200, Romania
[2] State Univ Ghent, Lab Med Biochem & Clin Anal, B-9000 Ghent, Belgium
[3] Free Univ Brussels, Lab Pharmaceut & Biomed Anal, B-1090 Brussels, Belgium
来源
TURKISH JOURNAL OF CHEMISTRY | 2002年 / 26卷 / 01期
关键词
principal component analysis; Soft Independent Modeling of Class Analogy; infrared spectrum; amphetamines; drugs of abuse;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The introduction of effective drug testing procedures in doping control reduced, but did not eliminate, their abuse by athletes. The most important analytical challenge is the recognition of the new analog compounds. In attempts to circumvent existing controlled substance laws, slightly modified chemical structures (by adding or changing substituents at various positions on the banned molecules) are used. As a result, no substance belonging to a prohibited class may be used nowadays, even if it has not been specifically listed. We present a chemometric procedure acting as an automated GC-FTIR screening test detecting the molecular structural similarity of unknown compounds with the main classes of ergogenic aids. The knowledge base defining the reference GC-FTIR spectral patterns has been built according to criteria encompassing toxicological, pharmacological and neurochemical aspects. The class identity of a compound is diagnosed within seconds, using Soft Independent Modeling of Class Analog (SIMCA). The predictive value of the system was assessed at a testing accuracy of 95%. Compounds giving cross-reactions with traditional screening techniques produce a negative result. The specificity and the selectivity of the screening test, evaluated by testing 160 toxicologically relevant compounds, are discussed, emphasizing the chemical and physical factors affecting these parameters. The specificity of the system recommends the procedure as a highly specific, selective, fast, and user-friendly screening test, which screens for ergogenic aids found in powders, tablets or solutions with a prediction accuracy adequate for investigations in analytical toxicology and doping control.
引用
收藏
页码:45 / 58
页数:14
相关论文
共 50 条
  • [31] Affected States Soft Independent Modeling by Class Analogy from the Relation Between Independent Variables, Number of Independent Variables and Sample Size
    Kanik, Emine Arzu
    Temel, Gulhan Orekici
    Erdogan, Semra
    Kaya, Irem Ersoz
    BALKAN MEDICAL JOURNAL, 2013, 30 (01) : 28 - 32
  • [32] RAW-MATERIALS TESTING USING SOFT INDEPENDENT MODELING OF CLASS ANALOGY ANALYSIS OF NEAR-INFRARED REFLECTANCE SPECTRA
    GEMPERLINE, PJ
    WEBBER, LD
    COX, FO
    ANALYTICAL CHEMISTRY, 1989, 61 (02) : 138 - 144
  • [33] Combining Infrared, Near Infrared with Soft Independent Modeling of Class Analogy for Identification of Vegetable Blend Oil
    Li Juan
    Fan Lu
    Bi Yan-Lan
    Qu Ling-Bo
    Deng De-Wen
    Zhou Zhan-Ming
    Wu Cun-Rong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (04) : 475 - 482
  • [34] Qualitative identification of tea by near infrared spectroscopy based on soft independent modelling of class analogy pattern recognition
    Chen, QS
    Zhao, JW
    Zhang, HD
    Liu, MH
    Fang, M
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2005, 13 (06) : 327 - 332
  • [35] Class modelling by Soft Independent Modelling of Class Analogy: why, when, how? A tutorial
    Vitale, Raffaele
    Cocchi, Marina
    Biancolillo, Alessandra
    Ruckebusch, Cyril
    Marini, Federico
    ANALYTICA CHIMICA ACTA, 2023, 1270
  • [36] Application of mid-infrared spectroscopy with multivariate analysis and soft independent modeling of class analogies (SIMCA) for the detection of adulterants in minced beef
    Meza-Marquez, Ofelia G.
    Gallardo-Velazquez, Tzayhri
    Osorio-Revilla, Guillermo
    MEAT SCIENCE, 2010, 86 (02) : 511 - 519
  • [37] Diagnosis of renal failure by infrared spectrometric analysis of human serum samples and soft independent modeling of class analogy
    Khanmohammadi, Mohammadreza
    Garmarudi, Amir Bagheri
    Ramin, Mehdi
    Ghasemi, Keyvan
    MICROCHEMICAL JOURNAL, 2013, 106 : 67 - 72
  • [38] Automatic soft independent modeling for class analogies
    Chen, Zewei
    Harrington, Peter de Boves
    ANALYTICA CHIMICA ACTA, 2019, 1090 : 47 - 56
  • [39] Identification of different woody biomass for energy purpose by means of Soft Independent Modeling of Class Analogy applied to thermogravimetric analysis
    Toscano, G.
    Duca, D.
    Rossini, G.
    Mengarelli, C.
    Pizzi, A.
    ENERGY, 2015, 83 : 351 - 357
  • [40] Diagnosis of basal cell carcinoma by infrared spectroscopy of whole blood samples applying soft independent modeling class analogy
    Mohammadreza Khanmohammadi
    Razieh Nasiri
    Keyvan Ghasemi
    Simin Samani
    Amir Bagheri Garmarudi
    Journal of Cancer Research and Clinical Oncology, 2007, 133 : 1001 - 1010