Phantom Measurements and Simulations of Cardiac and Brain Studies Using a Multipinhole Collimator with 20 Apertures

被引:0
|
作者
Bowen, Jason D. [1 ]
Huang, Qiu [2 ]
Gullberg, Grant T. [3 ]
Seo, Youngho [1 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94143 USA
[2] Shanghai Jiao Tong Univ, Shanghai 200030, Peoples R China
[3] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
关键词
Single photon emission computed tomography (SPECT); multipinhole; myocardial perfusion imaging (MPI); dual-isotope imaging;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
SPECT, despite its success, has an uncertain future This is partly due to the continued use of parallel hole collimators. These collimators possess poor geometric sensitivity which leads to increased study times and higher dose requirements. In recent years there has been activity investigating dedicated SPECT cameras which attempt to build on the strengths of SPECT while addressing its weaknesses. Here we present measurements of a cardiac and Hoffman brain phantom (Data Spectrum, Hillsborough, NC) performed with a pair of focusing 20-pinhole collimators with 7.5 mm diameter tungsten apertures mounted on an Infinia Hawkeye 4 dual-head SPECT/CT system (GE Uealthcare, Chalfont St. Giles, UK). Comparisons are made with measurements taken with LEUR parallelhole collimators. We also present an assessment of point source sensitivity and image resolution. The cardiac and brain phantoms contained 3.8 mCi and 1.5 mCi of 99mTc-pertechnetate (140 keV), respectively. The cardiac phantom was imaged with six 300 s views over 180 degrees and the brain phantom was imaged with eight 300 s views over 360 degrees. The gantry orbit was circular with a radius of rotation between 22.5 cm and 25.0 cm. Shortened study times were simulated by scaling the projection data and adding Poisson noise. The multipinhole projection data were then reconstructed with 300 iterations of MLEM. We find that despite the relatively large pinhole sizes we obtain image quality comparable to that obtained with LEHR collimators at a fraction the acquisition time. For the cardiac phantom good quality images are obtained in 10 minutes, while for the brain phantom comparable image quality is attained in 10 minutes. The measured point source sensitivity near the central field of view is 7.4 x 10(-4), and optimal resolution is between 9 mm and 13 mm. These results indicate that imaging performance approaching that capable with dedicated SPECT cameras may be possible with these collimators while leveraging the existing SPECT install base.
引用
收藏
页码:3417 / 3421
页数:5
相关论文
共 50 条
  • [31] Quantification of the uncertainty in coronary CTA plaque measurements using dynamic cardiac phantom and 3D-printed plaque models
    Richards, Taylor
    Sturgeon, Gregory M.
    Ramirez-Giraldo, Juan Carlos
    Rubin, Geoffrey
    Segars, Paul
    Samei, Ehsan
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [32] Optimization of block-matching and 3D filtering (BM3D) algorithm in brain SPECT imaging using fan beam collimator: Phantom study
    Do, Yongho
    Cho, Youngkwon
    Kang, Seong-Hyeon
    Lee, Youngjin
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (09) : 3403 - 3414
  • [33] Hydration studies on the archaeal protein Sso7d using NMR measurements and MD simulations
    Bernini, Andrea
    Spiga, Ottavia
    Consonni, Roberto
    Arosio, Ivana
    Fusi, Paola
    Cirri, Simone
    Guagliardi, Annamaria
    Niccolai, Neri
    BMC STRUCTURAL BIOLOGY, 2011, 11
  • [34] Estimation of the spatial resolution of [18F]-FDG brain PET(MR) scans using phantom measurements and human scan data
    Marques da Silva, A.
    Schramm, G.
    van Aalst, J.
    Mertens, N.
    Van Laere, K.
    Koole, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S789 - S789
  • [35] Tissue phantom studies on photon migration through fetal brain in-utero using near infra-red spectroscopy
    Vishnoi, G
    Hielscher, AH
    Ramanujam, N
    Nioka, S
    Chance, B
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 650 - 660
  • [36] Fast and robust localization of brain electrical sources using evolution strategies: Monte-carlo simulation and phantom experiment studies
    Im, CH
    Jung, HK
    Han, JY
    Lee, HR
    Lee, SY
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2004, 20 (3-4) : 197 - 203
  • [37] Comparison of ultrasound vector flow imaging and CFD simulations with PIV measurements of flow in a left ventricular outflow trackt phantom- Implications for clinical use and in silico studies
    Leinan, Paul Roger
    Gronli, Thomas
    Skjetne, Paal
    Wigen, Morten Smedsrud
    Urheim, Stig
    Lovstakken, Lasse
    Dahl, Sigrid K.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 146
  • [38] Effects of heart rate, filling and slice thickness on the accuracy of left ventricular volume measurements in a dynamic cardiac phantom using ECG-gated MDCT
    Dogan, H.
    Veldkamp, W. J. H.
    Dibbets-Schneider, P.
    Spijkerboer, A. M.
    Mertens, B. J. A.
    Kroft, L. J. M.
    De Roos, A.
    Geleijns, J.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (967): : 577 - 582
  • [39] Cirrus-induced shortwave radiative effects depending on their optical and physical properties: Case studies using simulations and measurements
    Cordoba-Jabonero, Carmen
    Gomez-Martin, Laura
    del Aguila, Ana
    Manuel Vilaplana, Jose
    Lopez-Cayuela, Maria-Angeles
    Zorzano, Maria-Paz
    ATMOSPHERIC RESEARCH, 2020, 246
  • [40] Evaluation of the dose to the bladder wall using a dynamic balloon-bladder phantom and TLD measurements in 18F-FDG PET studies
    Wu, TH
    Liu, RS
    Lin, YD
    Chou, KL
    Chong, NS
    Lee, JS
    NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (12) : 1153 - 1159