Phantom Measurements and Simulations of Cardiac and Brain Studies Using a Multipinhole Collimator with 20 Apertures

被引:0
|
作者
Bowen, Jason D. [1 ]
Huang, Qiu [2 ]
Gullberg, Grant T. [3 ]
Seo, Youngho [1 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94143 USA
[2] Shanghai Jiao Tong Univ, Shanghai 200030, Peoples R China
[3] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
关键词
Single photon emission computed tomography (SPECT); multipinhole; myocardial perfusion imaging (MPI); dual-isotope imaging;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
SPECT, despite its success, has an uncertain future This is partly due to the continued use of parallel hole collimators. These collimators possess poor geometric sensitivity which leads to increased study times and higher dose requirements. In recent years there has been activity investigating dedicated SPECT cameras which attempt to build on the strengths of SPECT while addressing its weaknesses. Here we present measurements of a cardiac and Hoffman brain phantom (Data Spectrum, Hillsborough, NC) performed with a pair of focusing 20-pinhole collimators with 7.5 mm diameter tungsten apertures mounted on an Infinia Hawkeye 4 dual-head SPECT/CT system (GE Uealthcare, Chalfont St. Giles, UK). Comparisons are made with measurements taken with LEUR parallelhole collimators. We also present an assessment of point source sensitivity and image resolution. The cardiac and brain phantoms contained 3.8 mCi and 1.5 mCi of 99mTc-pertechnetate (140 keV), respectively. The cardiac phantom was imaged with six 300 s views over 180 degrees and the brain phantom was imaged with eight 300 s views over 360 degrees. The gantry orbit was circular with a radius of rotation between 22.5 cm and 25.0 cm. Shortened study times were simulated by scaling the projection data and adding Poisson noise. The multipinhole projection data were then reconstructed with 300 iterations of MLEM. We find that despite the relatively large pinhole sizes we obtain image quality comparable to that obtained with LEHR collimators at a fraction the acquisition time. For the cardiac phantom good quality images are obtained in 10 minutes, while for the brain phantom comparable image quality is attained in 10 minutes. The measured point source sensitivity near the central field of view is 7.4 x 10(-4), and optimal resolution is between 9 mm and 13 mm. These results indicate that imaging performance approaching that capable with dedicated SPECT cameras may be possible with these collimators while leveraging the existing SPECT install base.
引用
收藏
页码:3417 / 3421
页数:5
相关论文
共 50 条
  • [21] Harmonization of brain PET images in multi-center PET studies using Hoffman phantom scan
    Shekari, Mahnaz
    Verwer, Eline E.
    Yaqub, Maqsood
    Daamen, Marcel
    Buckley, Christopher
    Frisoni, Giovanni B.
    Visser, Pieter Jelle
    Farrar, Gill
    Barkhof, Frederik
    Gispert, Juan Domingo
    Boellaard, Ronald
    EJNMMI PHYSICS, 2023, 10 (01)
  • [22] Harmonization of brain PET images in multi-center PET studies using Hoffman phantom scan
    Mahnaz Shekari
    Eline E. Verwer
    Maqsood Yaqub
    Marcel Daamen
    Christopher Buckley
    Giovanni B. Frisoni
    Pieter Jelle Visser
    Gill Farrar
    Frederik Barkhof
    Juan Domingo Gispert
    Ronald Boellaard
    EJNMMI Physics, 10
  • [23] Harmonization of Brain PET Images in Multi-Center PET Studies Using Hoffman Phantom Scan
    Shekari, M.
    Verwer, E.
    Yaqub, M.
    Gispert, J. D.
    Boellaard, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S188 - S188
  • [24] Volume measurements in nuclear medicine gated SPECT and 4D echocardiography:: validation using a dynamic cardiac phantom
    Debrun, D
    Thérain, F
    Nguyen, LD
    Léger, C
    Visser, J
    Busemann-Sokole, E
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3): : 239 - 247
  • [25] Volume measurements in nuclear medicine gated SPECT and 4D echocardiography: validation using a dynamic cardiac phantom
    Dominique Debrun
    Fabienne Thérain
    Long-Dang Nguyen
    Christophe P. Léger
    Jacco J. N. Visser
    The International Journal of Cardiovascular Imaging, 2005, 21 : 239 - 247
  • [26] Studies on simultaneous myocardial imaging with dual radionuclides (123I and 201Tl) using cardiac focusing collimator
    Kunimoto, K.
    Abe, S.
    Fujita, N.
    Sakuragi, Y.
    Odagawa, T.
    Koshiba, Y.
    Honda, M.
    Kato, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S658 - S658
  • [27] Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies
    Winant, Celeste D.
    Aparici, Carina Mari
    Zelnik, Yuval R.
    Reutter, Bryan W.
    Sitek, Arkadiusz
    Bacharach, Stephen L.
    Gullberg, Grant T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (02): : 375 - 393
  • [28] Studies on simultaneous myocardial imaging with dual radionuclides (123I and 201Tl) using cardiac focusing collimator
    Kunimoto, Keita
    Abe, Shinji
    Fujita, Naotoshi
    Sakuragi, Yasuhiro
    Odagawa, Tetsuro
    Koshiba, Yumiko
    Kato, Katsuhiko
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [29] Assessment of the dose distribution inside a cardiac cath lab using TLD measurements and Monte Carlo simulations
    Baptista, M.
    Teles, P.
    Cardoso, G.
    Vaz, P.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 163 - 169
  • [30] Macromolecular crowding studies of amino acids using NMR diffusion measurements and molecular dynamics simulations
    Virk, Amninder S.
    Stait-Gardner, Timothy
    Willis, Scott A.
    Torres, Allan M.
    Price, William S.
    FRONTIERS IN PHYSICS, 2015, 3 (FEB)