Volume measurements in nuclear medicine gated SPECT and 4D echocardiography: validation using a dynamic cardiac phantom

被引:0
|
作者
Dominique Debrun
Fabienne Thérain
Long-Dang Nguyen
Christophe P. Léger
Jacco J. N. Visser
机构
[1] Centre Hospitalier Régional d’ Orléans (CHRO),Service de Médecine Nucléaire
[2] Centre Hospitalier Régional d’ Orléans (CHRQ),Service de Cardiologie
[3] Université d’ Orléans,Laboratoire d’ Electronique Signaux Images (LESI)
[4] University of Amsterdam,Academic Medical Centre, Department of Nuclear Medicine
关键词
dynamic cardiac phantom; quality control; myocardial gated SPECT; 3D–4D echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
Purpose: A dynamic cardiac phantom was used as a reference to compare volumes measured with gated SPECT and 4D echocardiography. Material and Methods: Gated SPECT data were acquired with a standard single-head gamma camera, and the volume reconstructions were carried out using the Mirage software by Segami. 4D echocardiography used a new prototype of rotating scan head to acquire ultrasound images during a cardiac cycle, used to reconstruct the volume deformations as a function of time. End-diastolic volume, end-systolic volume, and ejection fraction were measured using both gated SPECT and 4D echocardiography. Results: The results obtained showed a good correlation between volumes measured with the two modalities, but a slight overestimation of volumes with gated SPECT. The influence of filtering and pixel size parameters on the measured volumes was quantified for gated SPECT, in order to correct the overestimation. Conclusion: The agreement between gated SPECT (after correction) and 4D echocardiography confirmed the relevance of the comparisons. This study was an initial step before conducting clinical trials to compare exhaustively left ventricular volumes obtained with the two modalities.
引用
收藏
页码:239 / 247
页数:8
相关论文
共 50 条
  • [1] Volume measurements in nuclear medicine gated SPECT and 4D echocardiography:: validation using a dynamic cardiac phantom
    Debrun, D
    Thérain, F
    Nguyen, LD
    Léger, C
    Visser, J
    Busemann-Sokole, E
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3): : 239 - 247
  • [2] Validation of a volumic reconstruction in 4-D echocardiography and gated spect using a dynamic cardiac phantom
    Nguyen, LD
    Léger, C
    Debrun, D
    Thérain, F
    Visser, J
    Sokole, EB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (08): : 1151 - 1160
  • [3] Validation in 4D Dosimetry Using Dynamic Phantom
    Lin, C.
    Huang, T.
    Lin, C.
    Nien, H.
    Tu, P.
    Lui, L.
    Wu, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3552 - 3553
  • [4] Validation of gated blood-pool SPECT cardiac measurements tested using a biventricular dynamic physical phantom
    De Bondt, P
    Nichols, K
    Vandenberghe, S
    Segers, P
    De Winter, O
    Van de Wiele, C
    Verdonck, P
    Shazad, A
    Shoyeb, AH
    De Sutter, J
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (06) : 967 - 972
  • [5] 4D RECONSTRUCTION OF GATED CARDIAC SPECT USING FOURIER HARMONICS
    Niu, Xiaofeng
    Yang, Yongyi
    2008 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO, VOLS 1-4, 2008, : 533 - 536
  • [6] 4D reconstruction for gated cardiac spect using fourier basis functions
    Niu, Xiaofeng
    Yang, Yongyi
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1473 - 1476
  • [7] Generation of realistic simultaneous cardiac and respiratory gated SPECT datasets using the 4D XCAT phantom and Monte Carlo simulation
    Lee, Taek-Soo
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [8] Validation of the path integration of 4D dose distributions with 4D phantom measurements
    Zhang, GG
    Guerrero, TM
    Forster, K
    Fischer, G
    Fitzpatrick, M
    Starkschall, G
    Ibbott, G
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S608 - S609
  • [9] 4D reconstruction for low-dose cardiac gated SPECT
    Jin, Mingwu
    Niu, Xiaofeng
    Qi, Wenyuan
    Yang, Yongyi
    Dey, Joyoni
    King, Michael A.
    Dahlberg, Seth
    Wernick, Miles N.
    MEDICAL PHYSICS, 2013, 40 (02)
  • [10] 4D RECONSTRUCTION FOR DUAL CARDIAC-RESPIRATORY GATED SPECT
    Qi, Wenyuan
    Yang, Yongyi
    Wernick, Miles N.
    King, Michael A.
    2013 20TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2013), 2013, : 2324 - 2328