Validation of a volumic reconstruction in 4-D echocardiography and gated spect using a dynamic cardiac phantom

被引:10
|
作者
Nguyen, LD
Léger, C
Debrun, D
Thérain, F
Visser, J
Sokole, EB
机构
[1] CHRO, Serv Cardiol, F-45067 Orleans 02, France
[2] CHRO, Serv Med Nucl, F-45067 Orleans, France
[3] Univ Orleans, LESI, Orleans, France
[4] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, Amsterdam, Netherlands
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2003年 / 29卷 / 08期
关键词
dynamic cardiac phantom; quality control; myocardial gated SPECT; 3-D/4-D echocardiography;
D O I
10.1016/S0301-5629(03)00975-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A dynamic cardiac phantom was used as a reference to compare the volumes reconstructed with 4-D echocardiography and gated single-photon emission computed tomography (SPECT). 4-D echocardiography used a new prototype of rotating scan head to acquire ultrasound (US) images during a cardiac cycle, associated with a new protocol (left ventricular 4-D or LV 4-D) to reconstruct the volume deformations of the heart as a function of time. Gated SPECT data were acquired with a standard single-head gamma camera, and the reconstructions were carried out using the Mirage software released by Segami. The influences of different LV 4-D parameters were tested and analyzed. End-diastolic volume, end-systolic volume, and ejection fraction were measured using both LV 4-D and gated SPECT. Results obtained showed a straight correlation between the two examinations. The agreement confirmed the relevance of the comparisons. This study is an initial step before conducting clinical trials to exhaustively compare the two modalities. (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1151 / 1160
页数:10
相关论文
共 50 条
  • [1] Volume measurements in nuclear medicine gated SPECT and 4D echocardiography:: validation using a dynamic cardiac phantom
    Debrun, D
    Thérain, F
    Nguyen, LD
    Léger, C
    Visser, J
    Busemann-Sokole, E
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3): : 239 - 247
  • [2] Volume measurements in nuclear medicine gated SPECT and 4D echocardiography: validation using a dynamic cardiac phantom
    Dominique Debrun
    Fabienne Thérain
    Long-Dang Nguyen
    Christophe P. Léger
    Jacco J. N. Visser
    [J]. The International Journal of Cardiovascular Imaging, 2005, 21 : 239 - 247
  • [3] Reconstruction of dynamic gated cardiac SPECT
    Jin, Mingwu
    Yang, Yongyi
    King, Michael A.
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4384 - 4394
  • [4] Use of a 4-D cardiac phantom to quantify Karhunen-Loeve images applied to myocardial gated SPECT
    Comas, L
    Berthout, P
    Sabbah, R
    Daspet, JP
    Blagosklonov, O
    Baud, M
    Verdenet, J
    Cardot, JC
    [J]. Computers in Cardiology 2005, Vol 32, 2005, 32 : 431 - 434
  • [5] 4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT
    Qi, Wenyuan
    Yang, Yongyi
    Song, Chao
    Wernick, Miles N.
    Pretorius, P. Hendrik
    King, Michael A.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (08) : 1626 - 1635
  • [6] 4D RECONSTRUCTION OF GATED CARDIAC SPECT USING FOURIER HARMONICS
    Niu, Xiaofeng
    Yang, Yongyi
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO, VOLS 1-4, 2008, : 533 - 536
  • [7] Improved image quality and computation reduction in 4-D reconstruction of cardiac-gated SPECT images
    Narayanan, MV
    King, MA
    Wernick, MN
    Byrne, CL
    Soares, EJ
    Pretorius, PH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 423 - 433
  • [8] Fully 4-D dynamic cardiac SPECT image reconstruction using spatiotemporal B-spline voxelization
    Reutter, Bryan W.
    Gullberg, Grant T.
    Boutchko, Rostyslav
    Balakrishnan, Karthikayan
    Botvinick, Elias H.
    Huesman, Ronald H.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4217 - +
  • [9] Validation of gated blood-pool SPECT cardiac measurements tested using a biventricular dynamic physical phantom
    De Bondt, P
    Nichols, K
    Vandenberghe, S
    Segers, P
    De Winter, O
    Van de Wiele, C
    Verdonck, P
    Shazad, A
    Shoyeb, AH
    De Sutter, J
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (06) : 967 - 972
  • [10] 4D reconstruction for gated cardiac spect using fourier basis functions
    Niu, Xiaofeng
    Yang, Yongyi
    [J]. 2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1473 - 1476