Use of a 4-D cardiac phantom to quantify Karhunen-Loeve images applied to myocardial gated SPECT

被引:0
|
作者
Comas, L [1 ]
Berthout, P [1 ]
Sabbah, R [1 ]
Daspet, JP [1 ]
Blagosklonov, O [1 ]
Baud, M [1 ]
Verdenet, J [1 ]
Cardot, JC [1 ]
机构
[1] Hop Jean Minjoz, Dept Nucl Cardiol, F-25030 Besancon, France
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Myocardial gated single photon computed tomography (gSPECT) is widely used for quantification of myocardial perfusion and contractile function. Using a modified 4D NCAT phantom, the purpose of this study was to evaluate the diagnostic performance of the Karhunen-Loeve transform (KLT) applied to gSPECT. For this purpose, perfusion was quantified by an index proportional to the size and the intensity of the defect (Pi) and kinetics by an index (Ki) which was the mean endocardial and epicardial wall motion. KLT provides an uncorrelated image series in which only the first two (KL0KL1) contain the main part of information. It was found that KL0 reflects perfusion and KL1 kinetics.
引用
下载
收藏
页码:431 / 434
页数:4
相关论文
共 17 条
  • [1] Application of the Karhunen-Loeve transform to 4D reconstruction of cardiac gated SPECT images
    Univ of Massachusetts Medical Sch, Worcester, United States
    IEEE Trans Nucl Sci, 4 II (1001-1008):
  • [2] Application of the Karhunen-Loeve transform to 4D reconstruction of cardiac gated SPECT images
    Narayanan, Manoj V.
    King, Michael A.
    Soares, Edward J.
    Byrne, Charles L.
    Pretorius, P.Hendrik
    Wernick, Miles N.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 1141 - 1145
  • [3] Application of the Karhunen-Loeve transform to 4D reconstruction of cardiac gated SPECT images
    Narayanan, MV
    King, MA
    Soares, EJ
    Byrne, CL
    Pretorius, PH
    Wernick, MN
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1001 - 1008
  • [4] Karhunen-Loeve transform for analysis of cardiac function in myocardial gated SPECT
    Blagosklonov, O
    Sabbah, R
    Berthout, P
    Comas, L
    Verdenet, J
    Baud, M
    Cardot, JC
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1217 - 1224
  • [5] Validation of a volumic reconstruction in 4-D echocardiography and gated spect using a dynamic cardiac phantom
    Nguyen, LD
    Léger, C
    Debrun, D
    Thérain, F
    Visser, J
    Sokole, EB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (08): : 1151 - 1160
  • [6] 4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT
    Qi, Wenyuan
    Yang, Yongyi
    Song, Chao
    Wernick, Miles N.
    Pretorius, P. Hendrik
    King, Michael A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (08) : 1626 - 1635
  • [7] Improved image quality and computation reduction in 4-D reconstruction of cardiac-gated SPECT images
    Narayanan, MV
    King, MA
    Wernick, MN
    Byrne, CL
    Soares, EJ
    Pretorius, PH
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 423 - 433
  • [8] Study of the efficacy of respiratory gating in myocardial SPECT using the new 4-D NCAT phantom
    Segars, WP
    Tsui, BMW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 675 - 679
  • [9] Volume measurements in nuclear medicine gated SPECT and 4D echocardiography:: validation using a dynamic cardiac phantom
    Debrun, D
    Thérain, F
    Nguyen, LD
    Léger, C
    Visser, J
    Busemann-Sokole, E
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3): : 239 - 247
  • [10] Volume measurements in nuclear medicine gated SPECT and 4D echocardiography: validation using a dynamic cardiac phantom
    Dominique Debrun
    Fabienne Thérain
    Long-Dang Nguyen
    Christophe P. Léger
    Jacco J. N. Visser
    The International Journal of Cardiovascular Imaging, 2005, 21 : 239 - 247