Volume measurements in nuclear medicine gated SPECT and 4D echocardiography: validation using a dynamic cardiac phantom

被引:0
|
作者
Dominique Debrun
Fabienne Thérain
Long-Dang Nguyen
Christophe P. Léger
Jacco J. N. Visser
机构
[1] Centre Hospitalier Régional d’ Orléans (CHRO),Service de Médecine Nucléaire
[2] Centre Hospitalier Régional d’ Orléans (CHRQ),Service de Cardiologie
[3] Université d’ Orléans,Laboratoire d’ Electronique Signaux Images (LESI)
[4] University of Amsterdam,Academic Medical Centre, Department of Nuclear Medicine
关键词
dynamic cardiac phantom; quality control; myocardial gated SPECT; 3D–4D echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
Purpose: A dynamic cardiac phantom was used as a reference to compare volumes measured with gated SPECT and 4D echocardiography. Material and Methods: Gated SPECT data were acquired with a standard single-head gamma camera, and the volume reconstructions were carried out using the Mirage software by Segami. 4D echocardiography used a new prototype of rotating scan head to acquire ultrasound images during a cardiac cycle, used to reconstruct the volume deformations as a function of time. End-diastolic volume, end-systolic volume, and ejection fraction were measured using both gated SPECT and 4D echocardiography. Results: The results obtained showed a good correlation between volumes measured with the two modalities, but a slight overestimation of volumes with gated SPECT. The influence of filtering and pixel size parameters on the measured volumes was quantified for gated SPECT, in order to correct the overestimation. Conclusion: The agreement between gated SPECT (after correction) and 4D echocardiography confirmed the relevance of the comparisons. This study was an initial step before conducting clinical trials to compare exhaustively left ventricular volumes obtained with the two modalities.
引用
收藏
页码:239 / 247
页数:8
相关论文
共 50 条
  • [41] Use of a 4-D cardiac phantom to quantify Karhunen-Loeve images applied to myocardial gated SPECT
    Comas, L
    Berthout, P
    Sabbah, R
    Daspet, JP
    Blagosklonov, O
    Baud, M
    Verdenet, J
    Cardot, JC
    Computers in Cardiology 2005, Vol 32, 2005, 32 : 431 - 434
  • [42] USING 4D ECHOCARDIOGRAPHY IMAGING TO EVALUATE THE EFFECT OF STROKE VOLUME ON MYOCARDIAL STRAIN
    Sahn, David
    Mathur, Priyanka
    Lei, Hao Chuan
    Hastie, Katie
    Farland, Gabriella
    Ashraf, Muhammad
    Streiff, Cole
    Zhu, Meihua
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1237 - A1237
  • [43] 4D measurements of biological and synthetic structures using a dynamic interferometer
    Toto-Arellano, Noel-Ivan
    JOURNAL OF MODERN OPTICS, 2017, 64 : S20 - S29
  • [44] Phantom validation of 4D flow: independent validation of flow velocity quantification using particle imaging velocimetry
    Johannes Töger
    Sebastian L Bidhult
    Johan Revstedt
    Marcus Carlsson
    Håkan Arheden
    Einar Heiberg
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [45] EVALUATION OF CARDIAC MECHANICS BASED ON ECHOPAC STRAIN ANALYSIS USING 4D ECHOCARDIOGRAPHY
    Sahn, David J.
    Amacher, Kacie
    Bleck, Rosie
    Zhu, Meihua
    Streiff, Cole
    Kimura, Sumito
    Ravi, Sreyas
    Park, Austin
    Ashraf, Muhammad
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1092 - E1092
  • [46] Preclinical Experience Using 4D Intracardiac Echocardiography to Guide Cardiac Electrophysiology Procedures
    Blumenthal, Colin J.
    Hsue, Weihow
    Chen, Tiffany
    Zhang, David
    Brem, Erez
    Garcia, Fermin C.
    Callans, David J.
    Marchlinski, Francis E.
    Santangeli, Pasquale
    Tschabrunn, Cory M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2025, 36 (02) : 480 - 486
  • [47] Validation of 4D Monte Carlo dose calculations using a programmable deformable lung phantom
    Gholampourkashi, Sara
    Cygler, Joanna E.
    Lavigne, Bernie
    Heath, Emily
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 16 - 27
  • [48] Effects of heart rate, filling and slice thickness on the accuracy of left ventricular volume measurements in a dynamic cardiac phantom using ECG-gated MDCT
    Dogan, H.
    Veldkamp, W. J. H.
    Dibbets-Schneider, P.
    Spijkerboer, A. M.
    Mertens, B. J. A.
    Kroft, L. J. M.
    De Roos, A.
    Geleijns, J.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (967): : 577 - 582
  • [49] Development of a 4D Digital Phantom for Tracer Kinetic Modeling and Analysis of Dynamic Perfusion PET and SPECT Simulation Studies
    Fung, George S. K.
    Higuchi, Takahiro
    Park, Min Jae
    Segars, W. Paul
    Tsui, Benjamin M. W.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4192 - 4195
  • [50] Integrated 4D Reconstruction of Dynamic Data for Myocardial Blood Flow Measurements with Dedicated SPECT Cameras
    Humphries, T.
    Wells, R. G.
    Celler, A.
    dekemp, R.
    MEDICAL PHYSICS, 2011, 38 (06)