Power quality evaluation at medical center

被引:0
|
作者
Hall, PW [1 ]
Bailey, BB [1 ]
Camm, EH [1 ]
机构
[1] Baptist Med Ctr, Little Rock, AR 72205 USA
关键词
'power quality; voltage sags; switching transients; CBEMA; static source transfer switching system; disturbance analyzer;
D O I
10.1109/TDC.1999.756113
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A power quality evaluation was conducted to determine (i) the cause of nuisance tripping of electrical equipment at Baptist Medical Center in Little Rock, Arkansas and (ii) whether there was any correlation of these nuisance tripping events with voltage sags on the utility system as a result of source-side faults. The facility's total connected load exceeds 6.5 MVA. The interruption of the facility's large chillers and associated air-conditioning equipment, as well as computer and critical diagnostic equipment were of particular concern. This paper describes the different stages of this power quality evaluation which included: (i) an on-site inspection of the facility's;'s electrical system, (ii) continuous power monitoring at the medium-voltage service entrance and at the utilization voltage buses of sensitive electrical equipment in the facility, and (iii) an evaluation of the applicability of a medium-voltage high-speed static source transfer switching system.
引用
收藏
页码:560 / 565
页数:6
相关论文
共 50 条
  • [41] Evaluation of an emergency medical center's information system
    Ghahramani, B
    [J]. 6TH INDUSTRIAL ENGINEERING RESEARCH CONFERENCE PROCEEDINGS: (IERC), 1997, : 668 - 673
  • [42] ALCOHOL WITHDRAWAL PROTOCOL EVALUATION AT AN ACADEMIC MEDICAL CENTER
    Archer, Sydney
    Knutson, Jace
    Stun, Lucy
    [J]. CRITICAL CARE MEDICINE, 2020, 48
  • [43] POST IMPLEMENTATION EVALUATION OF TELEDERMATOLOGY IN A VA MEDICAL CENTER
    Roman, M. M.
    Chiu, M.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2015, 63 (01) : 92 - 92
  • [44] Evaluation of Exposure to Tuberculosis Among Employees at a Medical Center
    de Perio, Marie A.
    Niemeier, R. Todd
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2014, 11 (06) : D63 - D68
  • [45] Patterns of Lecanemab Evaluation and Enrollment at an Academic Medical Center
    Arteaga, D. N.
    Lavalliere, J.
    Tall, S. Ouedraogo
    [J]. JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2024, 72 : S173 - S173
  • [46] A Critical Analysis of Power Quality Issues in Data Center
    Harinath, P.
    Kamaleswaran, K.
    Venkateshwaran, M.
    Sreenath, C.
    Prabhakaran, S.
    Kirubakaran, V.
    [J]. 2016 BIENNIAL INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS: TOWARDS SUSTAINABLE ENERGY (PESTSE), 2016,
  • [47] Evaluation of a power quality monitoring system
    Hipp, Walter
    Renner, Herwig
    [J]. PQ2008: 2008 POWER QUALITY AND SUPPLY RELIABILITY, CONFERENCE PROCEEDINGS, 2008, : 47 - 52
  • [48] Quality of colonoscopy preparation with polyethylene glycol at a VA medical center
    Imperiale, Thomas F.
    Kahi, Charles J.
    Abdullah, Ma'n
    Castelluccio, Peter
    Sutherland, Jason
    [J]. GASTROENTEROLOGY, 2007, 132 (04) : A348 - A348
  • [49] Enhancing the quality of the patient experience in an academic medical center.
    Colman, Gerard
    Hardeman, Emily
    Moorad, Julianna Grisham
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (31)
  • [50] Applying GRM on the Decision Process of Service Quality in Medical Center
    Kung, Chaang-Yung
    Yan, Tzung-Ming
    Huang, Chih-Cheng
    [J]. ICIAS 2007: INTERNATIONAL CONFERENCE ON INTELLIGENT & ADVANCED SYSTEMS, VOLS 1-3, PROCEEDINGS, 2007, : 286 - +