Power quality evaluation at medical center

被引:0
|
作者
Hall, PW [1 ]
Bailey, BB [1 ]
Camm, EH [1 ]
机构
[1] Baptist Med Ctr, Little Rock, AR 72205 USA
关键词
'power quality; voltage sags; switching transients; CBEMA; static source transfer switching system; disturbance analyzer;
D O I
10.1109/TDC.1999.756113
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A power quality evaluation was conducted to determine (i) the cause of nuisance tripping of electrical equipment at Baptist Medical Center in Little Rock, Arkansas and (ii) whether there was any correlation of these nuisance tripping events with voltage sags on the utility system as a result of source-side faults. The facility's total connected load exceeds 6.5 MVA. The interruption of the facility's large chillers and associated air-conditioning equipment, as well as computer and critical diagnostic equipment were of particular concern. This paper describes the different stages of this power quality evaluation which included: (i) an on-site inspection of the facility's;'s electrical system, (ii) continuous power monitoring at the medium-voltage service entrance and at the utilization voltage buses of sensitive electrical equipment in the facility, and (iii) an evaluation of the applicability of a medium-voltage high-speed static source transfer switching system.
引用
收藏
页码:560 / 565
页数:6
相关论文
共 50 条
  • [31] Sleep quality evaluation in medical students
    Ezquiaga, A. D.
    Vas, C. P.
    Nieto, G. P.
    Blanco, S. A.
    Schwemler, M.
    Roca, L.
    Garcia, A. M.
    Prost, J. O.
    [J]. JOURNAL OF THE NEUROLOGICAL SCIENCES, 2015, 357 : E435 - E435
  • [32] EVALUATION OF QUALITY OF INFANT MEDICAL RECORDS
    TRAINOR, PE
    WHALEN, RP
    [J]. NEW YORK STATE JOURNAL OF MEDICINE, 1967, 67 (13) : 1911 - &
  • [33] EVALUATION OF MEDICAL-CARE QUALITY
    ROGER, FH
    [J]. ACTA CLINICA BELGICA, 1988, 43 (03): : 219 - 230
  • [34] VENEZUELAN MEDICAL JOURNALS - EVALUATION OF THEIR QUALITY
    ARENDS, T
    [J]. ACTA CIENTIFICA VENEZOLANA, 1968, 19 (04): : 148 - &
  • [35] A case study of power quality in a health care facility waiter Reed Army Medical Center, Washington DC
    Quarrie, LO
    Walchle, RL
    [J]. NORTHCON/96 - IEEE TECHNICAL APPLICATIONS CONFERENCE, CONFERENCE RECORD, 1996, : 230 - 235
  • [36] INTRODUCING QUALITY ASSURANCE AND MEDICAL AUDIT INTO UCSF MEDICAL-CENTER CURRICULUM
    BARBACCIA, JC
    [J]. JOURNAL OF MEDICAL EDUCATION, 1976, 51 (05): : 386 - 391
  • [37] Evaluation on Training Quality of Henan Electric Power Co. Training Center Based on Markov Chain
    Zhang Qingwei
    Li Ziyao
    [J]. COMPREHENSIVE EVALUATION OF ECONOMY AND SOCIETY WITH STATISTICAL SCIENCE, 2010, : 475 - 479
  • [38] Comprehensive Evaluation of Thyroid FNAs at an Academic Medical Center
    Liu, Xiaoying
    Li, Zhigang
    Moroishi, Yuka
    Vaickus, Louis
    Nguyen, Lananh
    Gutmann, Edward
    Marotti, Jonathan
    [J]. MODERN PATHOLOGY, 2018, 31 : 158 - 158
  • [39] Comprehensive Evaluation of Thyroid FNAs at an Academic Medical Center
    Liu, Xiaoying
    Li, Zhigang
    Moroishi, Yuka
    Vaickus, Louis
    Nguyen, Lananh
    Gutmann, Edward
    Marotti, Jonathan
    [J]. LABORATORY INVESTIGATION, 2018, 98 : 158 - 158
  • [40] EVALUATION OF NEED FOR ESTABLISHMENT OF A CENTER FOR ADVANCED MEDICAL TECHNOLOGY
    YONENAKA, H
    WU, WG
    FLETCHER, DW
    [J]. AMERICAN JOURNAL OF MEDICAL TECHNOLOGY, 1969, 35 (06): : 381 - &