Effect of Lens Care Systems on the Clinical Performance of a Contact Lens

被引:48
|
作者
de la Jara, Percy Lazon [1 ,3 ]
Papas, Eric [1 ,2 ,3 ]
Diec, Jennie [1 ]
Naduvilath, Thomas [1 ]
Willcox, Mark D. P. [3 ]
Holden, Brien A. [1 ,2 ,3 ]
机构
[1] Brien Holden Vis Inst, Sydney, NSW, Australia
[2] Vis Cooperat Res Ctr, Sydney, NSW, Australia
[3] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
关键词
silicone hydrogel; discomfort; dryness; adverse events; CORNEAL INFILTRATIVE EVENTS; SILICONE HYDROGEL LENSES; RISK-FACTORS; OCULAR SURFACE; DAILY WEAR; MULTIPURPOSE SOLUTIONS; EXTENDED WEAR; DEPOSITS; REGIMEN;
D O I
10.1097/OPX.0b013e318288e10c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate subjective responses, rates of solution-induced corneal staining (SICS), and corneal infiltrative events (CIEs) associated with a silicone hydrogel when worn under a daily disposable (DD) or daily wear (DW) modality. Methods. Data were obtained from seven prospective clinical trials, involving 283 subjects wearing Senofilcon A contact lenses (Johnson and Johnson Vision Care, Jacksonville, FL). Four groups wore the contact lens on a DW basis using multipurpose solutions (DW-MPS, n = 160), two groups using hydrogen peroxide (DW-H2O2, n = 83), and one group as a DD (n = 40). Participants were followed for 3 months using the same protocol. Subjective ratings were compared between DD and DW groups using a linear mixed model. Rates of SICS and CIE were calculated as the percent frequency of first events within the 3-month study. Association of SICS and CIE with subjective responses was analyzed using a linear mixed model. Results. End-of-day comfort and dryness ratings were significantly better for DD (8.5 +/- 1.7 and 8.6 +/- 1.7, respectively) compared with DW-H2O2 (7.7 +/- 1.8, p = 0.01; 7.6 +/- 1.9, p = 0.006, respectively) and DW-MPS (7.7 +/- 1.7, p = 0.004; 7.6 +/- 2.0, p = 0.003, respectively). Compared with DD, a higher incidence of CIE and SICS was found for DW-MPS (0.0 vs. 3.9%, p = 0.021; 0.9 vs. 8.6%, p = 0.002, respectively). Comfort at insertion and end of day and end-of-day dryness scores were significantly lower for participants who experienced SICS (8.2 +/- 1.6, 7.0 +/- 1.9, and 7.0 +/- 2.2) than those who did not (8.8 +/- 1.2, p = 0.004; 7.9 +/- 1.7, p = 0.002; and 7.9 +/- 1.8, p = 0.003, respectively). Comfort at insertion scores were significantly lower for participants who experienced CIEs than those who did not (8.2 +/- 1.5 vs. 8.8 +/- 1.4, p = 0.032). Conclusions. Senofilcon A clinical response is modulated by the lens care products. All lens care products tested reduced subjective responses relative to DD modality, whereas MPS increased the incidence of CIEs and SICS. Senofilcon A performs best when used on a DD basis. (Optom Vis Sci 2013;90:344-350)
引用
收藏
页码:344 / 350
页数:7
相关论文
共 50 条
  • [31] Contact lens user profile, attitudes and level of compliance to lens care
    Wu, Yvonne
    Carnt, Nicole
    Stapleton, Fiona
    [J]. CONTACT LENS & ANTERIOR EYE, 2010, 33 (04): : 183 - 188
  • [32] Effect of Lens and Solution Choice on the Comfort of Contact Lens Wearers
    Tilia, Daniel
    de la Jara, Percy Lazon
    Peng, Nikki
    Papas, Eric B.
    Holden, Brien A.
    [J]. OPTOMETRY AND VISION SCIENCE, 2013, 90 (05) : 411 - 418
  • [33] The Effect of Microblepharon Exfoliation on Clinical Correlates of Contact Lens Discomfort
    Siddireddy, Jaya Sowjanya
    Tan, Jacqueline
    Vijay, Ajay Kumar
    Willcox, Mark D. P.
    [J]. OPTOMETRY AND VISION SCIENCE, 2019, 96 (03) : 187 - 199
  • [34] The Effect of Contact Lens Hygiene Behavior on Lens Case Contamination
    Wu, Yvonne T.
    Willcox, Mark D. P.
    Stapleton, Fiona
    [J]. OPTOMETRY AND VISION SCIENCE, 2015, 92 (02) : 167 - 174
  • [35] The effect of uncorrected astigmatism on the reading performance of contact lens neophytes
    Gil Fernandez, Pedro
    Farcas, Alexandra
    Hernandez, Celia
    Benito, Antonio
    Tabernero, Juan
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [36] Combined Effect of Comfort and Adverse Events on Contact Lens Performance
    Diec, Jennie
    Papas, Eric
    Naduvilath, Thomas
    Xu, Pauline
    Holden, Brien A.
    de la Jara, Percy Lazon
    [J]. OPTOMETRY AND VISION SCIENCE, 2013, 90 (07) : 674 - 681
  • [37] BACILLUS KERATITIS ASSOCIATED WITH CONTAMINATED CONTACT-LENS CARE SYSTEMS
    DONZIS, PB
    MONDINO, BJ
    WEISSMAN, BA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (02) : 195 - 197
  • [38] MICROBIAL ANALYSIS OF CONTACT-LENS CARE SYSTEMS CONTAMINATED WITH ACANTHAMOEBA
    DONZIS, PB
    MONDINO, BJ
    WEISSMAN, BA
    BRUCKNER, DA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (01) : 53 - 56
  • [39] ANTIMICROBIAL EFFECTIVENESS OF SOME SOFT CONTACT-LENS CARE SYSTEMS
    TSE, LSY
    CALLENDER, MG
    CHARLES, AM
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1987, 64 (11): : 824 - 828
  • [40] CLINICAL EXPERIENCE WITH HYDROPHILIC CONTACT LENS
    GRUBER, E
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1970, 70 (05) : 833 - &