Effect of Lens Care Systems on the Clinical Performance of a Contact Lens

被引:48
|
作者
de la Jara, Percy Lazon [1 ,3 ]
Papas, Eric [1 ,2 ,3 ]
Diec, Jennie [1 ]
Naduvilath, Thomas [1 ]
Willcox, Mark D. P. [3 ]
Holden, Brien A. [1 ,2 ,3 ]
机构
[1] Brien Holden Vis Inst, Sydney, NSW, Australia
[2] Vis Cooperat Res Ctr, Sydney, NSW, Australia
[3] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
关键词
silicone hydrogel; discomfort; dryness; adverse events; CORNEAL INFILTRATIVE EVENTS; SILICONE HYDROGEL LENSES; RISK-FACTORS; OCULAR SURFACE; DAILY WEAR; MULTIPURPOSE SOLUTIONS; EXTENDED WEAR; DEPOSITS; REGIMEN;
D O I
10.1097/OPX.0b013e318288e10c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate subjective responses, rates of solution-induced corneal staining (SICS), and corneal infiltrative events (CIEs) associated with a silicone hydrogel when worn under a daily disposable (DD) or daily wear (DW) modality. Methods. Data were obtained from seven prospective clinical trials, involving 283 subjects wearing Senofilcon A contact lenses (Johnson and Johnson Vision Care, Jacksonville, FL). Four groups wore the contact lens on a DW basis using multipurpose solutions (DW-MPS, n = 160), two groups using hydrogen peroxide (DW-H2O2, n = 83), and one group as a DD (n = 40). Participants were followed for 3 months using the same protocol. Subjective ratings were compared between DD and DW groups using a linear mixed model. Rates of SICS and CIE were calculated as the percent frequency of first events within the 3-month study. Association of SICS and CIE with subjective responses was analyzed using a linear mixed model. Results. End-of-day comfort and dryness ratings were significantly better for DD (8.5 +/- 1.7 and 8.6 +/- 1.7, respectively) compared with DW-H2O2 (7.7 +/- 1.8, p = 0.01; 7.6 +/- 1.9, p = 0.006, respectively) and DW-MPS (7.7 +/- 1.7, p = 0.004; 7.6 +/- 2.0, p = 0.003, respectively). Compared with DD, a higher incidence of CIE and SICS was found for DW-MPS (0.0 vs. 3.9%, p = 0.021; 0.9 vs. 8.6%, p = 0.002, respectively). Comfort at insertion and end of day and end-of-day dryness scores were significantly lower for participants who experienced SICS (8.2 +/- 1.6, 7.0 +/- 1.9, and 7.0 +/- 2.2) than those who did not (8.8 +/- 1.2, p = 0.004; 7.9 +/- 1.7, p = 0.002; and 7.9 +/- 1.8, p = 0.003, respectively). Comfort at insertion scores were significantly lower for participants who experienced CIEs than those who did not (8.2 +/- 1.5 vs. 8.8 +/- 1.4, p = 0.032). Conclusions. Senofilcon A clinical response is modulated by the lens care products. All lens care products tested reduced subjective responses relative to DD modality, whereas MPS increased the incidence of CIEs and SICS. Senofilcon A performs best when used on a DD basis. (Optom Vis Sci 2013;90:344-350)
引用
收藏
页码:344 / 350
页数:7
相关论文
共 50 条
  • [21] Comparison by contact lens cytology and clinical tests of three contact lens types
    Wilson, G
    Schwallie, JD
    Bauman, RE
    [J]. OPTOMETRY AND VISION SCIENCE, 1998, 75 (05) : 323 - 329
  • [22] Microbial contamination of contact lens storage cases with the use of different contact lens care solutions and lens materials
    Dantam, Jaya
    McCanna, David J.
    Subbaraman, Lakshman N.
    Lakkis, Carol
    Morgan, Philip B.
    Nichols, Jason J.
    Jones, Lyndon William
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [23] Clinical performance of a novel toric silicone hydrogel contact lens
    Subbaraman, Lakshman N.
    Gustafson, Britt
    Whaley, Susan
    Giedd, Bradley
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [24] Lens surface roughening for tears invariant contact lens performance
    Zalevsky, Zeev
    Azogui, Jonathan
    Limon, Ofer
    Rudnitsky, Arkady
    [J]. OPTICS COMMUNICATIONS, 2014, 315 : 168 - 175
  • [25] Clinical Evaluation of Long-Term Users of Two Contact Lens Care Preservative Systems
    Young, Graeme
    Keir, Nancy
    Hunt, Chris
    Woods, Craig A.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (02): : 50 - 58
  • [26] The influence of lens care systems on eyelid tissue changes during silicone hydrogel contact lens wear
    Guillon, Michel
    Maissa, Cecile
    Wong, Stephanie
    Patel, Trisha
    Garofalo, Renee
    [J]. CONTACT LENS & ANTERIOR EYE, 2018, 41 (04): : 362 - 368
  • [27] COMPLIANCE IN CONTACT-LENS CARE
    CHUN, MW
    WEISSMAN, BA
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1987, 64 (04): : 274 - 276
  • [28] CONTACT-LENS CARE AND COMPLICATIONS
    WHITE, GL
    THIESE, SM
    LUNDERGAN, MK
    [J]. AMERICAN FAMILY PHYSICIAN, 1988, 37 (04) : 187 - 192
  • [29] Contemporary research in contact lens care
    Morgan, Philip B.
    [J]. CONTACT LENS & ANTERIOR EYE, 2013, 36 : S22 - S27
  • [30] Internet Survey on Contact Lens Care
    Wang, Margaret
    Gunasekaran, Vidhya
    Nawazish, Saba
    Kim, Don Byongdo
    Phan, Victoria
    Trinh, Christina
    Wu, Gloria
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)