Effect of Lens Care Systems on the Clinical Performance of a Contact Lens

被引:48
|
作者
de la Jara, Percy Lazon [1 ,3 ]
Papas, Eric [1 ,2 ,3 ]
Diec, Jennie [1 ]
Naduvilath, Thomas [1 ]
Willcox, Mark D. P. [3 ]
Holden, Brien A. [1 ,2 ,3 ]
机构
[1] Brien Holden Vis Inst, Sydney, NSW, Australia
[2] Vis Cooperat Res Ctr, Sydney, NSW, Australia
[3] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
关键词
silicone hydrogel; discomfort; dryness; adverse events; CORNEAL INFILTRATIVE EVENTS; SILICONE HYDROGEL LENSES; RISK-FACTORS; OCULAR SURFACE; DAILY WEAR; MULTIPURPOSE SOLUTIONS; EXTENDED WEAR; DEPOSITS; REGIMEN;
D O I
10.1097/OPX.0b013e318288e10c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate subjective responses, rates of solution-induced corneal staining (SICS), and corneal infiltrative events (CIEs) associated with a silicone hydrogel when worn under a daily disposable (DD) or daily wear (DW) modality. Methods. Data were obtained from seven prospective clinical trials, involving 283 subjects wearing Senofilcon A contact lenses (Johnson and Johnson Vision Care, Jacksonville, FL). Four groups wore the contact lens on a DW basis using multipurpose solutions (DW-MPS, n = 160), two groups using hydrogen peroxide (DW-H2O2, n = 83), and one group as a DD (n = 40). Participants were followed for 3 months using the same protocol. Subjective ratings were compared between DD and DW groups using a linear mixed model. Rates of SICS and CIE were calculated as the percent frequency of first events within the 3-month study. Association of SICS and CIE with subjective responses was analyzed using a linear mixed model. Results. End-of-day comfort and dryness ratings were significantly better for DD (8.5 +/- 1.7 and 8.6 +/- 1.7, respectively) compared with DW-H2O2 (7.7 +/- 1.8, p = 0.01; 7.6 +/- 1.9, p = 0.006, respectively) and DW-MPS (7.7 +/- 1.7, p = 0.004; 7.6 +/- 2.0, p = 0.003, respectively). Compared with DD, a higher incidence of CIE and SICS was found for DW-MPS (0.0 vs. 3.9%, p = 0.021; 0.9 vs. 8.6%, p = 0.002, respectively). Comfort at insertion and end of day and end-of-day dryness scores were significantly lower for participants who experienced SICS (8.2 +/- 1.6, 7.0 +/- 1.9, and 7.0 +/- 2.2) than those who did not (8.8 +/- 1.2, p = 0.004; 7.9 +/- 1.7, p = 0.002; and 7.9 +/- 1.8, p = 0.003, respectively). Comfort at insertion scores were significantly lower for participants who experienced CIEs than those who did not (8.2 +/- 1.5 vs. 8.8 +/- 1.4, p = 0.032). Conclusions. Senofilcon A clinical response is modulated by the lens care products. All lens care products tested reduced subjective responses relative to DD modality, whereas MPS increased the incidence of CIEs and SICS. Senofilcon A performs best when used on a DD basis. (Optom Vis Sci 2013;90:344-350)
引用
收藏
页码:344 / 350
页数:7
相关论文
共 50 条
  • [1] Effect of lens care systems on the clinical performance of a contact lens
    De La Jara, Percy Lazon
    Papas, Eric
    Diec, Jennie
    Naduvilath, Thomas
    Willcox, Mark D.P.
    Holden, Brien A.
    [J]. Optometry and Vision Science, 2013, 90 (04): : 344 - 350
  • [2] Effect of Lens Care Systems on Silicone Hydrogel Contact Lens Hydrophobicity
    Lira, Madalena
    Silva, Rita
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (02): : 89 - 94
  • [3] The effect of soft contact lens care products on lens modulus
    Young, G.
    Garofalo, R.
    Harmer, O.
    Peters, S.
    [J]. CONTACT LENS & ANTERIOR EYE, 2010, 33 (05): : 210 - 214
  • [4] Effect of lens care system on silicone hydrogel contact lens wettability
    Maissa, Cecile
    Guillon, Michel
    Wong, Stephanie
    Lane, Anna
    Patel, Trisha
    Garofalo, Renee
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Effect of lens care system on silicone hydrogel contact lens wettability
    Guillon, Michel
    Maissa, Cecile
    Wong, Stephanie
    Patel, Trisha
    Garofalo, Renee
    [J]. CONTACT LENS & ANTERIOR EYE, 2015, 38 (06): : 435 - 441
  • [6] CURRENT CONTACT-LENS CARE SYSTEMS
    SIBLEY, M
    [J]. INTERNATIONAL OPHTHALMOLOGY CLINICS, 1991, 31 (02) : 13 - 16
  • [7] Efficacy of a contact lens cleaning device and its enhancement of the performance of contact lens care products
    Ifejika, CP
    McLaughlin-Borlace, L
    Lucas, VJ
    Roberts, ADG
    Walker, JT
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (05) : 539 - 541
  • [8] Ocular response to lens care systems in adolescent soft contact lens wearers
    Soni, PS
    Horner, DG
    Ross, J
    [J]. OPTOMETRY AND VISION SCIENCE, 1996, 73 (02) : 70 - 85
  • [9] Detection and Quantification of Tear Phospholipids and Cholesterol in Contact Lens Deposits: The Effect of Contact Lens Material and Lens Care Solution
    Saville, Jennifer T.
    Zhao, Zhenjun
    Willcox, Mark D. P.
    Blanksby, Stephen J.
    Mitchell, Todd W.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (06) : 2843 - 2851
  • [10] Multipurpose Lens Care Systems and Silicone Hydrogel Contact Lens Wettability: A Systematic Review
    Capote-Puente, Raul
    Sanchez-Gonzalez, Jose-Maria
    Bautista-Llamas, Maria-Jose
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (09): : 356 - 361