Investigation of the radiological properties of various phantoms for their application in low energy X-rays dosimetry

被引:14
|
作者
Langaroodi, Roghayeh Kargar Shaker [1 ]
Abtahi, Seyed Mohammad Mahdi [1 ]
Akbari, Mohammad Esmaeil [2 ]
机构
[1] Imam Khomeini Int Univ, Phys Dept, Qazvin 3414916818, Iran
[2] Shahid Beheshti Univ Med Sci, Canc Res Ctr, Tehran, Iran
关键词
Phantom; Radiological properties; Dosimetry; Low energy X-rays; Radiation therapy; EFFECTIVE ATOMIC NUMBERS; POLYMER GEL DOSIMETER; INTRAOPERATIVE RADIOTHERAPY; WATER EQUIVALENCE; MINIATURE; RADIOSURGERY; SIMULATION; DEVICE;
D O I
10.1016/j.radphyschem.2018.12.010
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
It has been previously proven that the radiological properties of materials are strongly dependent on the incident radiation energy. Hence, the present study aimed to evaluate the radiological properties and soft tissue equivalency of conventional phantoms at the 1-50 keV photon energy as well as the feasibility study of using a more appropriate material instead of water. The equivalence of water and a number of conventional phantoms with breast and muscle were evaluated in terms of mass density (rho), effective electron density (N-eff), effective atomic number (Z(eff)), photon mass energy-absorption coefficient (mu(en)/rho), photon mass attenuation coefficient (mu/rho), total stopping power of electrons (S/rho)(tot) and the absorbed depth dose by using the Auto-Z(eff) software and XCOM, ESTAR database and Monte Carlo simulation method. The differences of rho, N-eff, Z(eff) and (S/rho)(tot) between investigated materials and breast were 0.5-17%, 0.2-9%, 0.7-26%, and 2-11%, respectively. Additionally, the differences of mu(en)/rho, mu/rho, and the absorbed depth dose between the investigated phantom materials and breast tissue were 18-56%, 16-53%, and 5-79% respectively. Also, the differences of rho, N-eff, Z(eff), mu(en)/rho, mu/rho, (S/rho)(tot), and the absorbed depth dose between the investigated phantom materials and muscle were 1-14%, 2-9%, 1-33%, 4-67%, 6-63%, 1-15% and 3-93%, respectively. Water cannot be considered as breast tissue equivalent phantom in the energy range of 1-50 keV. Moreover, the results of depth dose investigation showed that the GENIPIN gel is the most suitable breast tissue substitute in intraoperative radiotherapy method.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [1] ACCURATE DOSIMETRY OF LOW-ENERGY X-RAYS
    LYONS, PB
    BARAN, JA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (02): : 908 - &
  • [2] Dosimetry of Low-Energy Characteristic X-Rays
    Tucker, M.
    Starin, R.
    McCray, M.
    Rakowski, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [3] The use of Fricke dosimetry for low energy X-rays
    de Austerlitz, C
    Souza, V
    Villar, HP
    Cordilha, A
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2006, 49 : 17 - 23
  • [4] THE APPLICATION OF MICRODOSIMETRIC MEASUREMENTS TO THE STUDY OF THE DOSIMETRY OF LOW-ENERGY X-RAYS
    WAKER, AJ
    EIVAZI, MT
    RADIATION PROTECTION DOSIMETRY, 1989, 29 (1-2) : 75 - 79
  • [5] Suitability of radiochromic films for dosimetry of low energy X-rays
    Ebert, Martin A.
    Asad, Ali H.
    Siddiqui, Salim A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04): : 232 - 240
  • [6] DOSIMETRY OF LOW-ENERGY X-RAYS USING LIF
    LAW, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (01): : 38 - 45
  • [7] Preclinical modeling of low energy X-rays radiological burn: Dosimetry study by monte carlo simulations and EPR spectroscopy
    Guillou, Manon
    L'Homme, Bruno
    Trompier, Francois
    Gruel, Gaetan
    Prezado, Yolanda
    Dos Santos, Morgane
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [8] Radiochromic film containing spiropyran dye for dosimetry of low energy X-rays
    Kinashi, Kenji
    Miyashita, Yusuke
    Ishida, Kenji
    Ueda, Yasukiyo
    JOURNAL OF PHYSICAL ORGANIC CHEMISTRY, 2012, 25 (05) : 427 - 430
  • [9] TLD-700 for proton dosimetry in the presence of low-energy X-rays
    Miljanic, S
    Ranogajec-Komor, M
    Blagus, S
    Miljanic, D
    Osvay, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 519 (03): : 667 - 673
  • [10] A VACUUM CHAMBER INVESTIGATION OF LOW ENERGY ELECTRONS LIBERATED BY X-RAYS
    GREENING, JR
    RANDLE, KJ
    BRITISH JOURNAL OF RADIOLOGY, 1968, 41 (487): : 534 - &